In this report, we derive analytical expressions for the time resolution limits of standard silicon sensors, LGADs, and 3D trench sensors. We separately examine the effects of Landau fluctuations and electronic noise. To analyze Landau fluctuations, we relate the time resolution of a single electron-hole pair generated at a random position in the sensor to the time resolution associated with the full ionization pattern produced by a charged particle. For electronic noise, we explore optimal filtering techniques that minimize its impact on time resolution, and evaluate how closely these can be approximated by practical filters. Finally, we demonstrate that the combined effect of Landau fluctuations and electronic noise cannot, in general, be simply expressed as the quadratic sum of the individual contributions.
Silicon Wafer Fracture Stress for Tracking Sensors in Particle Physics Experiments
Brookhaven National Laboratory(布鲁克海文国家实验室);Santa Cruz Institute of Particle Physics, University of California(加州大学圣克鲁兹粒子物理研究所);Department of Physics, University of Liverpool(利物浦大学物理系);Institute of Astronomy at the University of Cambridge(剑桥大学天文学研究所);TRIUMF(特里厄姆夫实验室);Department of Physics, Simon Fraser University(西蒙菲莎大学物理系);Particle Physics Department, STFC Rutherford Appleton Laboratory(STFC鲁瑟福阿普尔顿实验室粒子物理部);Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室)
Study of the readout chip and silicon sensor degradation for the CMS pixel upgrade
混合硅像素探测器目前用于紧凑型μ子螺线管(CMS)实验的最内部跟踪系统。已经证明了大型强子对撞机(LHC)运行几年所能承受的辐射通量,尽管预计硅探测器靠近相互作用点的部分会出现一些退化。在大型强子对撞机升级阶段,硅像素探测器预计的剂量水平将高得多。为了面对这个方面,已经在硅传感器和读出芯片上执行了具有高于$\mathcal{O}(10^{15})$ n $_{\textrm{eq}}$ /cm $^2$的注量的专用辐照测试。在操作中的传感器和读出芯片的能量密度的函数的变化。的电荷收集效率进行了研究:部分恢复的检测器的效率,可以通过操作的检测器在一个受控的环境中,并在较高的偏置电压。
Fast calculation of capacitances in silicon sensors with 3D and 2D numerical solutions of the Laplace's equation and comparison with experimental data and TCAD simulations
Testbeam studies of pre-prototype silicon strip sensors for the LHCb UT upgrade project
LHCb实验正准备在2018-2019年进行重大升级。升级的关键组件之一是位于实验分析磁体上游的新硅跟踪器。上游跟踪器(UT)将由硅条探测器的四个平面组成,每个平面覆盖约2 m $^2$的面积。这些探测器的一个重要考虑因素是它们在暴露于大辐射剂量后的性能。在这篇文章中,我们提出了预原型的n-in-p和p-in-n传感器,已被照射的能量密度高达$4.0\times10^{14}$ $n_{\rm eq}$ cm $^{-2}$的测试束结果。
Experimental Study of Different Silicon Sensor Options for the Upgrade of the CMS Outer Tracker
在计划于2027年左右开始的大型强子对撞机(HL-LHC)的高光度阶段,加速器预计将提供高达$7.5\times10^{34}$ cm $^{-2}$ s $^{-1}$的瞬时峰值光度。预计在未来十年内,$3000$或甚至$4000$ ~fb $^{-1}$的总积分亮度将被交付给通用探测器ATLAS和CMS,从而显著增加LHC实验的发现潜力。CMS探测器将为HL-LHC进行重大升级,全新的跟踪探测器由外部跟踪器和内部跟踪器组成。然而,新的跟踪系统将暴露在比当前跟踪器高得多的辐射下,需要新的抗辐射传感器。CMS从2009年开始发起了一项广泛的辐照和测量活动,系统地比较不同硅材料的特性和外跟踪器传感器的设计选择。在18种不同的晶圆材料、厚度和生产技术组合上设计并实现了几种测试结构和传感器。在用中子和不同能量的质子辐照之前和之后,对装置进行电气表征,其中通量对应于在$3000$ ~fb $^{-1}$之后CMS外跟踪器的不同半径处预期的通量。所执行的测试包括使用$β$源、激光和光束扫描的研究。本文比较了HL-LHC硅传感器的不同选择的性能,重点是硅块材料和厚度。
First application of machine learning algorithms to the position reconstruction in Resistive Silicon Detectors
RSD(阻性交流耦合硅探测器)是基于LGAD(低增益雪崩二极管)技术的n in p硅传感器,在整个传感器区域上具有连续的增益层。这些传感器真正的创新特征是,电离粒子引起的信号在几个像素上可见,从而允许使用结合来自许多读出通道的信息的重建技术。在这方面的贡献,机器学习技术的RSD设备的第一个应用程序。这种技术的空间分辨率相比,获得与标准RSD重建方法,使用信号共享机制的分析描述。使用模拟数据和真实数据的组合训练的多输出回归算法导致具有100 $μm$像素的传感器的空间分辨率小于2 $μm$。并对今后的改进方向进行了展望。
Characterization of p-stop isolation implants in silicon sensors using MOSFET structures
Marietta Blau Institute for Particle Physics, Austrian Academy of Sciences(马里埃塔·布劳粒子物理研究所,奥地利科学院);National Technical University of Athens(雅典国立技术大学);European Organization for Nuclear Research CERN(欧洲核子研究组织(CERN))
研究用 MOSFET 测试结构表征 p 型硅传感器中 p-stop 隔离注入,通过测量器件转移特性提取相关参数,提出重建掺杂分布方法,评估其对不同 p-stop 几何形状和掺杂浓度的灵敏度,证明该结构可作无损诊断监测相关特性。
Characterisation of Gamma-irradiated MCz-Silicon Detectors with a High-$K$ Negative Oxide as Field Insulator
大型强子对撞机(LHC)实验中紧凑型μ子Solenid(CMS)探测器中的跟踪器的高亮度操作要求开发硅基传感器。这涉及到交流耦合到微尺度像素传感器区域的实现,以提供增强的辐射感应漏电流的隔离。本研究的动机是开发具有负氧化物(例如氧化铝- Al $_2$ O $_3$和氧化铪- HfO $_2$)作为场绝缘体的AC像素传感器,所述场绝缘体具有良好的介电强度并提供抗辐射性。采用原子层沉积法(ALD)制备了Al $_2$ O $_3$和HfO $_2$薄膜作为电容耦合介质。基于MOS电容器中使用的介电材料的比较研究表明HfO $_2$是更好的候选材料,因为它对伽马辐照的负电荷积累提供了更高的灵敏度(其中,术语灵敏度定义为平带电压与剂量的变化之比)。此外,对于在高电阻率p型磁性直拉硅(MCz-Si)衬底上处理的传感器观察到空间电荷符号反转,所述衬底用高达1 MGy的剂量的伽马射线照射。高伽马辐照AC耦合像素传感器的像素间电阻值表明,作为场绝缘体的高$K$负氧化物在像素之间提供了良好的电隔离。
在成功安装并首次运行升级后的内部跟踪系统(ITS2)后,它由大约$10\,$ m $^2$的单片硅像素传感器组成,ALICE正在为LHC Run 4的ITS3率先使用弯曲的晶圆级像素传感器。可以使用拼接技术来生产大于典型标线尺寸的传感器。在约$30\,μ$ m的厚度下,硅足够柔性以弯曲到$1\,$ cm量级的半径。通过用强制气流冷却这种传感器,可以构造实际上仅由硅传感器组成的真正的圆柱形层。材料预算的减少和指向分辨率的提高将允许新的测量,特别是重味衰变和电磁探针。在这次演讲中,我们将报告传感器的发展,弯曲传感器在测试梁的性能,和真正的圆柱形层的力学研究。
Novel Multi-pixel Silicon Photon Detectors and Applications in T2K
如今,诸如高能物理(HEP)、医学成像设备、便携式辐射探测器等的众多领域,需要一种坚固、小型、可靠和容易获得的光子检测器,其在各种环境中,例如在强磁场存在下是稳定的。最近可用的$\sim$ 1 mm $^{\textrm{2}}$有源区多像素光子计数器(MPPC)传感器,由滨松光子学公司生产,已被发现是可靠的,是一个有吸引力的选择,用于HEP应用。以下传感器特性已经过T2 K合作组织的全面测试:增益、暗噪声、检测效率、可靠性。这些似乎是稳定的;此外,还评估了许多器械之间的特征扩散。具有较大面积的传感器正在开发用于成像和直接与闪烁体耦合的目的。
Radiation effects on surface and bulk properties of ATLAS18 silicon sensors under low- and high-dose gamma irradiation and annealing
Institute of Physics, Academy of Sciences of the Czech Republic(捷克科学院物理研究所);Santa Cruz Institute for Particle Physics (SCIPP)(圣克鲁斯粒子物理研究所);UJP Praha a.s.(UJP布拉格有限公司);Experimental Particle Physics Department, Jožef Stefan Institute(约瑟夫斯特凡研究所实验粒子物理部);Instituto de Microelectronica de Barcelona (IMB-CNM), CSIC(西班牙国家科学研究委员会巴塞罗那微电子研究所);Institute of Particle and Nuclear Study, High Energy Accelerator Research Organization (KEK)(高能加速器研究机构粒子核研究部);Physikalisches Institut, Albert-Ludwigs-Universität Freiburg(弗赖堡大学物理研究所)
Development and characterization of a large area silicon pad array for an electromagnetic calorimeter
我们目前的研究和开发工作的第一个版本的6*6阵列的硅垫探测器,在印度进行,为拟议的前向量热计(FOCAL)的ALICE合作升级计划的一部分,在欧洲核子研究中心。主要的动机是开发一个大面积的硅垫阵列实现高能量物理实验的挑战性要求,如低漏电流,高击穿电压,并评估其性能作为原型硅钨(Si-W)电磁(EM)量能器中的有源层。为了实现这些目标,在班加罗尔的Bharat Electronics Limited,在4英寸高电阻率N型晶片上设计了一个36焊盘的硅传感器,其单个焊盘尺寸为1 cm 2。该传感器已被用于组装原型硅钨量热计,并成功地与高能粒子束测试。本文报道了大面积硅传感器的设计、研制及其在实验室用放射源和高能粒子束上的特性。