硅晶圆断裂应力用于粒子物理实验中的跟踪传感器

Silicon Wafer Fracture Stress for Tracking Sensors in Particle Physics Experiments

Brookhaven National Laboratory(布鲁克海文国家实验室);Santa Cruz Institute of Particle Physics, University of California(加州大学圣克鲁兹粒子物理研究所);Department of Physics, University of Liverpool(利物浦大学物理系);Institute of Astronomy at the University of Cambridge(剑桥大学天文学研究所);TRIUMF(特里厄姆夫实验室);Department of Physics, Simon Fraser University(西蒙菲莎大学物理系);Particle Physics Department, STFC Rutherford Appleton Laboratory(STFC鲁瑟福阿普尔顿实验室粒子物理部);Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室)

Haider Abidi, Vitaliy Fadeyev, Tim Jones, Akhil Kumar, Tom Lee, Luise Poley, Craig Sawyer, Giorgio Vallone, Sven Wonsak

AI总结:

本文研究ATLAS内部跟踪器硅传感器在低温下因热膨胀不匹配而断裂的问题,通过测试晶圆切片断裂应力,揭示模块间差异源于硅晶圆本身。

摘要:

在ATLAS内部跟踪器条带探测器的建造中,硅条带传感器模块使用软硅胶直接粘合到碳纤维支撑结构上。在低于-35°C的温度测试中,由于聚酰亚胺电路板(带有铜金属层,粘合在传感器上)与硅传感器本身之间的热膨胀系数不匹配,发现多个传感器出现裂纹。虽然开发了模块组装程序以最小化模块之间的差异,但冷测试显示,本应相当的模块在失效时表现出广泛的温度范围。对于本应相当的模块,观察到的方差(断裂温度在-35°C至-70°C之间)表明模块之间存在未被检测到的差异,怀疑这种差异是硅晶圆本身固有的。因此,开发了一个测试程序来研究代表性传感器晶圆切片的断裂应力。本文介绍了用于探测器模块的硅传感器断裂应力的结果。

英文摘要:

For the construction of the ATLAS Inner Tracker strip detector, silicon strip sensor modules are glued directly onto carbon fibre support structures using a soft silicone gel. During tests at temperatures below \unit[-35]{$^{\circ}$C}, several of the sensors were found to crack due to a mismatch in coefficients of thermal expansion between polyimide circuit boards with copper metal layers (glued onto the sensor) and the silicon sensor itself. While module assembly procedures were developed to minimise variations between modules, cold tests showed a wide range of temperatures at which supposedly comparable modules failed. The observed variance (fracture temperatures between \unit[-35]{\textcelsius} and \unit[-70]{\textcelsius}) for supposedly comparable modules suggests an undetected variation between modules suspected to be intrinsic to the silicon wafer itself. Therefore, a test programme was developed to investigate the fracture stress of representative sensor wafer cutoffs. This paper presents results for the fracture stress of silicon sensors used in detector modules.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑