arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2602.18135physics.ins-det
收藏

SIDDHARTA-2大型面积硅漂移探测器扩展X射线能谱学研究至50 keV

Extended X-ray energy characterization of SIDDHARTA-2 large-area Silicon Drift Detectors up to 50 keV

Laboratori Nazionali di Frascati INFN(弗兰斯卡蒂国家实验室 INFN);University of Palermo(巴勒莫大学);University of Zagreb(萨格勒布大学);Horia Hulubei National Institute of Physics and Nuclear Engineering (IFIN-HH)(霍里亚·胡卢贝伊核物理与核工程国家研究所);Czech Technical University in Prague(布拉格捷克理工大学);Jagiellonian University(雅盖隆大学);Fondazione Bruno Kessler(布鲁诺·凯斯勒基金会);Technical University Vienna(维也纳工业大学);Tohoku University(东北大学)
Francesco Clozza, Francesco Sgaramella, Leonardo Abbene, Francesco Artibani, Massimiliano Bazzi, Giacomo Borghi, Damir Bosnar, Mario Bragadireanu, Antonino Butt… 展开作者

Francesco Clozza, Francesco Sgaramella, Leonardo Abbene, Francesco Artibani, Massimiliano Bazzi, Giacomo Borghi, Damir Bosnar, Mario Bragadireanu, Antonino Buttacavoli, Marco Carminati, Alberto Clozza, Raffaele Del Grande, Luca De Paolis, Kamil Dulski, Francesco Ficorella, Carlo Fiorini, Ivica Friščić, Carlo Guaraldo, Mihail Iliescu, Masa Iwasaki, Aleksander Khreptak, Simone Manti, Johann Marton, Pawel Moskal, Fabrizio Napolitano, Szymon Niedźwiecki, Hiroaki Ohnishi, Antonino Picciotto, Kristian Piscicchia, Fabio Principato, Alessandro Scordo, Michał Silarski, Diana Sirghi, Florin Sirghi, Magdalena Skurzok, Antonio Spallone, Kairo Toho, Oton Vazquez Doce, Nicola Zorzi, Johann Zmeskal, Catalina Curceanu

AI总结:

SIDDHARTA-2实验利用SDD系统研究kaonic原子X射线能谱,实现50 keV精度的能量校准。

摘要:

SIDDHARTA-2实验在INFN-LNF的DA$Φ$NE对撞机上进行高精度轻kaonic原子X射线光谱学研究,以探测低能(约10 keV量级)范围内kaon-核子的强相互作用。开发了一套大面积硅漂移探测器(SDDs)系统用于这些测量。该合作旨在将测量计划扩展至更高质量的kaonic原子,这些原子表现出更高的X射线能级跃迁。在此背景下,研究了SIDDHARTA-2 SDD系统的光谱响应,包括线性度和能量分辨率,直至50 keV。实现了能量校准程序的精度ΔE/E < 10^{-3}。

英文摘要:

The SIDDHARTA-2 experiment at the DA$Φ$NE collider of INFN-LNF performs high precision light kaonic atoms X-ray spectroscopy to investigate the kaon-nucleon(s) strong interaction in the low-energy (O(10 keV)) regime. A large area Silicon Drift Detectors (SDDs) system has been developed to carry out these measurements. The collaboration aims to extend the measurements campaign to higher mass kaonic atoms, which exhibit transition lines at increased X-ray energies. In this context, the spectroscopic response of the SIDDHARTA-2 SDD system was investigated in terms of linearity and energy resolution up to 50 keV. An accuracy of the energy calibration procedure $ΔE/E < 10^{-3}$ was achieved.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑