arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2210.10219physics.ins-detcond-mat.mtrl-sci
收藏

几种硬X射线光子计数像素阵列探测器的本底率

Background Rates in Several Hard X-Ray Photon Counting Pixel Array Detectors

Alfred Q. R. Baron, Daisuke Ishikawa

摘要:

研究了几种像素阵列探测器的背景速率,目的是在非常低的速率实验中(例如,信号速率<0.1/s/cm ^2)将它们用于>6 keV的硬X射线。在SPring-8的实验地面上,使用未屏蔽的0.75 mm厚CdTe传感器的探测器测得的本底事件率从6 keV低能级跃迁(LLD)阈值的0.4/s/cm ^2变化到75 keV LLD阈值的0.2/s/cm ^2。具有1 mm厚硅传感器的探测器的背景较小,对于3 keV阈值为约0.08/s/cm^2,在17 keV阈值下降至约0.07/s/cm^2。这些速率主要由陆地来源决定,例如混凝土中微量杂质发射的伽马射线,直接探测宇宙射线μ子(CRM)的贡献很小,<0.01/s/cm 2。15 mm的Pb屏蔽层将CdTe中的测量速率降低至< 0.05/s/cm 2,并且将1 mm硅中的测量速率降低至<0.02/s/cm^2。额外的处理,“时间切片”,如可以在低速率实验中使用的,其中背景可能是最有问题的,被示出为进一步降低背景速率,对于硅传感器降低到< 0.004/s/cm ^2,对于CdTe降低到0.002和0.02/s/cm ^2之间,其中CdTe的精确值敏感地取决于检测器阈值,以及重新触发的使用和/或双触发阈值的使用。本底率作为阈值,屏蔽和处理的函数。我们还讨论的幅度,和校正,检测器的动态范围的限制,可以引入的时间切片。最后,我们提出了一个使用时间切片的例子。

英文摘要:

Background rates in several pixel array detectors are investigated with an eye toward using them with hard, >6 keV, x-rays in very low-rate experiments - e.g. at signal rates <0.1/s/cm^2. Measured background event rates for a detector with an unshielded 0.75 mm thick CdTe sensor on the experimental floor at SPring-8 varied from 0.4/s/cm^2 with a 6 keV lower-level discriminator (LLD) threshold to 0.2/s/cm^2 with a 75 keV LLD threshold. The background for a detector with a 1 mm thick silicon sensor was smaller, ~0.08/s/cm^2 for a 3keV threshold dropping to ~0.07/s/cm^2 at a 17 keV threshold. These rates are dominated by terrestrial sources, such as gamma rays emitted from trace impurities in concrete, with only a small contribution, <0.01/s/cm2, from direct detection of cosmic ray muons (CRMs). 15 mm of Pb shielding reduces the measured rates to < 0.05/s/cm2 in CdTe and to <0.02/s/cm^2 in 1 mm silicon. Additional processing, "time slicing", as may be used in low-rate experiments where backgrounds may be most problematic, is shown to reduce the background rates further, to < 0.004/s/cm^2 with the silicon sensor, and to between 0.002 and 0.02/s/cm^2 for CdTe, where the exact value for CdTe depends sensitively on the detector threshold, and the use of the retriggering and/or the use of dual discriminator thresholds. Background rates are presented as functions of discriminator threshold, shielding, and processing. We also discuss the magnitude of, and the correction for, the limitation of the detector dynamic range that can be introduced by the time slicing. Finally, we present one example where time slicing was used.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑