TiAu TES 32 $\times$ 32像素阵列:不同X射线能量下的均匀性、热串扰和性能

TiAu TES 32$\times$32 pixel array: uniformity, thermal crosstalk and performance at different X-ray energies

E. Taralli, M. D'Andrea, L. Gottardi, K. Nagayoshi, M. Ridder, S. Visser, M. de Wit, D. Vaccaro, H. Akamatsu, K. Ravensberg, R. Hoogeveen, M. Bruijn, J. R. Gao

摘要:

大型转换边缘传感器阵列是下一代空间X射线观测系统的关键。这种阵列需要在软X射线能量范围内实现$\mathrmΔE<$ 3 eV半峰全宽(FWHM)的能量分辨率。我们目前正在开发X射线微量热计阵列,作为由欧空局领导的ATHENA空间望远镜上的X-IFU仪器的备份选项,预计将于2031年发射。在这篇文章中,我们报告了一个均匀的32 $\times$ 32像素阵列的开发和表征(长度$\times $宽度)140 $\times$ 30 $μ$ m $^2$ TiAu TES,它具有用于X射线光子的\textcolor{black}{a 2.3 $μ$m}厚Au吸收体。像素具有典型的正常电阻$R_\mathrm{n}$ = 121 m $Ω$和临界温度$T_\mathrm{c}\sim$ 90 mK。我们对阵列中的60个像素进行了广泛的测量,以显示阵列的均匀性。我们获得了2.4和2.6 eV之间的能量分辨率(FWHM)在5.9 keV,在单像素模式下测量的交流偏置频率范围从1到5 MHz,与频域复用(FDM)读出系统,这是在SRON/VTT开发。我们还提出了探测器的能量分辨率在X射线与不同的光子能量产生的调制外部X射线源从1.45 keV到8.9 keV。跨几个像素的多路复用读出也被执行,以评估热串扰对仪器的能量分辨率预算要求的影响。当考虑串扰信号的幅度与X射线脉冲(例如,在5.9 keV下)之间的比率时,该值导致对于第一邻居的导出要求小于1 $\times$ 10 $^{-3}$。

英文摘要:

Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led by ESA and foreseen to be launched in 2031. In this contribution, we report on the development and the characterization of a uniform 32$\times$32 pixel array with (length$\times $width) 140$\times$30 $μ$m$^2$ TiAu TESs, which have \textcolor{black}{a 2.3 $μ$m} thick Au absorber for X-ray photons. The pixels have a typical normal resistance $R_\mathrm{n}$ = 121 m$Ω$ and a critical temperature $T_\mathrm{c}\sim$ 90 mK. We performed extensive measurements on 60 pixels out of the array in order to show the uniformity of the array. We obtained an energy resolutions between 2.4 and 2.6 eV (FWHM) at 5.9 keV, measured in a single-pixel mode at AC bias frequencies ranging from 1 to 5 MHz, with a frequency domain multiplexing (FDM) readout system, which is developed at SRON/VTT. We also present the detector energy resolution at X-ray with different photon energies generated by a modulated external X-ray source from 1.45 keV up to 8.9 keV. Multiplexing readout across several pixels has also been performed to evaluate the impact of the thermal crosstalk to the instrument's energy resolution budget requirement. This value results in a derived requirement, for the first neighbour, that is less than 1$\times$10$^{-3}$ when considering the ratio between the amplitude of the crosstalk signal to an X-ray pulse (for example at 5.9 keV)

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑