arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1111.4901physics.ins-det
收藏

利用TCAD模拟优化硅像素传感器在高剂量X射线下的辐射硬度

Optimization of the Radiation Hardness of Silicon Pixel Sensors for High X-ray Doses using TCAD Simulations

J. Schwandt, E. Fretwurst, R. Klanner, I. Pintilie, J. Zhang

摘要:

欧洲X射线自由电子激光器(XFEL)每秒将提供27000个完全相干的高亮度X射线脉冲,每个脉冲的持续时间低于100 fs。这将允许记录单个分子的衍射图案和研究超快过程。正在为XFEL开发的探测器系统之一是自适应增益积分像素探测器(AGIPD),它由一个像素阵列组成,该像素阵列的读出ASIC凸点键合到一个像素为200 μm \times 200 μm的硅传感器上。对探测器的特殊要求是高动态范围(0,1至10 E5 12 keV光子/XFEL脉冲),快速读出和辐射耐受性高达1 GGy的12 keV X射线剂量为3年的操作。在该X射线能量下,预期硅中没有体损伤。然而,SiO2层中的固定氧化物电荷和Si-SiO2界面处的界面陷阱将积累。研究了12 keV X射线剂量对测试结构中微观缺陷的影响和分段式传感器的宏观电学性能的影响。从测试结构的氧化物电荷密度,界面陷阱的密度和它们的属性作为剂量的函数已被确定。据发现,这两个饱和(甚至减少)的剂量以上几个MGy。对于分段传感器,由X射线引入的表面损伤增加了完全耗尽电压、表面漏电流和像素间电容。此外,在Si-SiO2界面处形成电子积累层,该层随剂量增加而增加,随外加电压减小而减小。使用TCAD模拟与剂量相关的损伤参数从测试结构,测量的结果可以重现。这允许针对XFEL要求优化传感器设计。

英文摘要:

The European X-ray Free Electron Laser (XFEL) will deliver 27000 fully coherent, high brilliance X-ray pulses per second each with a duration below 100 fs. This will allow the recording of diffraction patterns of single molecules and the study of ultra-fast processes. One of the detector systems under development for the XFEL is the Adaptive Gain Integrating Pixel Detector (AGIPD), which consists of a pixel array with readout ASICs bump-bonded to a silicon sensor with pixels of 200 μm \times 200 μm. The particular requirements for the detector are a high dynamic range (0, 1 up to 10E5 12 keV photons/XFEL-pulse), a fast read-out and radiation tolerance up to doses of 1 GGy of 12 keV X-rays for 3 years of operation. At this X-ray energy no bulk damage in silicon is expected. However fixed oxide charges in the SiO2 layer and interface traps at the Si-SiO2 interface will build up. As function of the 12 keV X-ray dose the microscopic defects in test structures and the macro- scopic electrical properties of segmented sensors have been investigated. From the test structures the oxide charge density, the density of interface traps and their properties as function of dose have been determined. It is found that both saturate (and even decrease) for doses above a few MGy. For segmented sensors surface damage introduced by the X-rays increases the full depletion voltage, the surface leakage current and the inter-pixel capacitance. In addition an electron accumulation layer forms at the Si-SiO2 interface which increases with dose and decreases with applied voltage. Using TCAD simulations with the dose dependent damage parameters obtained from the test struc- tures the results of the measurements can be reproduced. This allows the optimization of the sensor design for the XFEL requirements.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑