The Linear Collider Flavour Identification (LCFI) collaboration studies CCD detectors for quark flavour identification in the framework of a future linear e+e- collider. The flavour identification is based on precision reconstruction of charged tracks very close to the interaction point. Therefore, this detector will be exposed to a high level of radiation and thus an important aspect of the vertex detector development are radiation hardness studies. Results of detailed simulations of the charged transport properties of a CCD prototype chip are reported and compared with initial measurements. The simulation program allows to study the effect of radiation damage after the exposure of the detector to a realistic radiation dose, which is expected in the environment of detector operation at a future LC.
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) for the vertex detector of a future Linear Collider. The CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating speed. A test stand for measuring the charge transfer inefficiency (CTI) of a prototy…
Results of detailed simulations of the charge transfer inefficiency of a prototype serial readout CCD chip are reported. The effect of radiation damage on the chip operating in a particle detector at high frequency at a future accelerator is studied, specifically the creation of two electron trap levels, 0.17 eV and 0.44 eV below the bottom of the conduction band. Good agreement is found between simulations using the ISE-TCAD DESSIS program and an analytical model for the former level but not for the latter. Optimum operation is predicted to be at about 250 K where the effects of the traps is …
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) for the vertex detector of a future Linear Collider. The CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating speed. An Analytic Model has been developed for the determination of the charge trans…
We have investigated the radiation damage effects on a CCD to be employed in the Japanese X-ray astronomy mission including the Monitor of All-sky X-ray Image (MAXI) onboard the International Space Station (ISS). Since low energy protons release their energy mainly at the charge transfer channel, resulting a decrease of the charge transfer efficiency, we thus focused on the low energy protons in our experiments. A 171 keV to 3.91 MeV proton beam was irradiated to a given device. We measured the degradation of the charge transfer inefficiency (CTI) as a function of incremental fluence. A 292 ke…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) Collaboration has been developing Column-Parallel CCDs for the vertex detector of a future Linear Collider which can be read out many times faster than standard CCDs. The most recent studies are of devices designed to reduce both the CCD's intergate capacitance and the clock voltages necessary to driv…
Results of detailed simulations of the charge transfer inefficiency of a prototype CCD chip are reported. The effect of radiation damage in a particle detector operating at a future accelerator is studied by examining two electron trap levels, 0.17 eV and 0.44 eV below the bottom of the conduction band. Good agreement is found between simulations using the ISE-TCAD DESSIS program and an analytical model for the 0.17 eV level. Optimum operation is predicted to be at about 250 K where the effect of the traps is minimal which is approximately independent of readout frequency. This work has been c…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) for the vertex detector of the International Linear Collider (ILC). The CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating speed. The results of detailed simulations of the charge transfer inef…
The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. The vertex detector is located near the interaction point, thus high radiation tolerance is required. Charge transfer efficiency of CCD is degraded by radiation damage which makes traps in pixels. We measured charge transfer inefficiency (CTI) of a neutron irradiated FPCCD prototype. We observed a degradation of CTI compared with non-irradiated CCD. To improve the CTI of irradiated CCD, we performed the fat-zero charge injection to fill the traps. In this paper, we report a status of CTI improve…
Throughout a typical Earth orbit a satellite is constantly bombarded by radiation with trapped and solar protons being of particular concern as they gradually damage the focal plane devices throughout the mission and degrade their performance. To understand the impact the damage has on CCDs and how it varies with their thermal history a proton radiation campaign has been carried out using a CCD280. The CCD is irradiated at 153 K and gradually warmed to 188 K in 5 K increments with Fe55 X-ray, dark current and trap pumping images taken at 153 K after each anneal step. The results show that desp…
After launch, the Advanced CCD Imaging Spectrometer (ACIS), a focal plane instrument on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. An effect of the damage was to increase the charge transfer inefficiency (CTI) of the front illuminated CCDs. As part of the initial damage assessment, the focal plane was warmed from the operating temperature of -100C to +30C which unexpectedly further increased the CTI. We report results of ACIS CCD irradiation experiments in the lab aimed at better understanding this…
We report the radiation hardness of a p-channel CCD developed for the X-ray CCD camera onboard the XRISM satellite. This CCD has basically the same characteristics as the one used in the previous Hitomi satellite, but newly employs a notch structure of potential for signal charges by increasing the implant concentration in the channel. The new device was exposed up to approximately $7.9 \times 10^{10} \mathrm{~protons~cm^{-2}}$ at 100 MeV. The charge transfer inefficiency was estimated as a function of proton fluence with an ${}^{55} \mathrm{Fe}$ source. A device without the notch structure wa…
Fine pixel CCD (FPCCD) is one of the candidate sensor technologies for the vertex detector used for experiments at the International Linear Collider (ILC). A vertex detector system for the International Large Detector (ILD) using FPCCD sensors has been designed. We report on the R&D status of FPCCD sensors, as well as the vertex detector design for ILD.
Fine pixel CCD (FPCCD) is one of the candidate sensor technologies for the vertex detector used for experiments at the International Linear Collider (ILC). FPCCD vertex detector is supposed to be cooled down to -40 degree for improvement of radiation immunity. For this purpose, a two-phase CO2 cooling system using a gas compressor for CO2 circulation is being developed at KEK. The status of this R&D is presented in this article.
One of the major physics goals at the ILC is the precise measurement of the Higgs coupling constants to b-quarks and c-quarks. To achieve this measurement, we need a high-performance vertex detector leading to precise flavor tagging. For this purpose, we are developing the Fine Pixel CCD (FPCCD) vertex detector. In this paper, we will report on the development status of FPCCDTrackFinder, a new track finder improving tracking efficiency, especially in the low $p_t$ region, and an evaluation result of the flavor tagging performance with FPCCDTrackFinder in the FPCCD vertex detector.
Charge Coupled Devices (CCDs) have been successfully used in several low energy X-ray astronomical satellite over the past two decades. Their high energy resolution and high spatial resolution make them an perfect tool for low energy astronomy, such as formation of galaxy clusters and environment of black holes. The Low Energy X-ray Telescope (LE) group is developing Swept Charge Device (SCD) for the Hard X-ray Modulation Telescope (HXMT) satellite. SCD is a special low energy X-ray CCD, which could be read out a thousand times faster than traditional CCDs, simultaneously keeping excellent ene…
We are developing the vertex detector with a fine pixel CCD (FPCCD) for the international linear collider (ILC), whose pixel size is $5 \times 5$ $μ$m$^{2}$. To evaluate the performance of the FPCCD vertex detector and optimize its design, development of the software dedicated for the FPCCD is necessary. We, therefore, started to develop the software for FPCCD. In this article, the status of the study is reported.
As a candidate of the vertex detector for experiments at ILC, fully depleted fine pixel CCDs (FPCCDs) are under development. We describe the basic concept of the FPCCD and report on preliminary results of the performance study of the first prototype FPCCD sensors.
We develop the vertex detector for the international linear collider (ILC) using the FPCCD (Fine Pixel CCD), whose pixel size is 5 x 5 um2. Together with the FPCCD sensor, a prototype of the readout ASIC was developed in 2008. The readout ASIC was confirmed to work correctly at slow readout speed (1.5 Mpix/sec). In this letter, we describe the status of the performance study for the readout ASIC.
One of candidates for the International Linear Collider(ILC)'s vertex detector is the Fine Pixel CCD (FPCCD) with a pixel size of 5 \times 5 (\mum^2). Sensor and readout systems are currently being studied and prototypes have been developed. In this paper we will report on the performance of latest developed readout ASIC prototype as well as the outline of the design strategy for the next ASIC prototype.
Fine pixel CCD (FPCCD) is an option for the sensor used for the ILC vertex detector to reduce the pixel occupancy due to the high background rate near the interaction point. In this paper, we report on the R&D status of FPCCD sensors and the R&D plan for the sensors and the cooling system.
The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. It will be located near interaction point and require high radiation tolerance. It will thus be operated at -40 degree C to improve radiation tolerance. In this paper, we report on the status of neutron radiation tests, on a cooling system using two-phase CO2 with a gas compressor for circulation, and on the mechanical structure of the FPCCD ladders.
We investigate the possibility of tracking individual hydrogen micro-spheres from an internal pellet target. Such a method aims to provide the primary vertex of a reaction to within about 100 micrometres, without utilizing any detector response. Apart from background considerations the knowledge of the reaction vertex may be essential for the reconstruction of many physics channels. This is in particular true for the study of the Psi(3770) decay into D-mesons planned at the PANDA detector at the future FAIR facility. Here, the reconstruction of displaced vertices is especially difficult since …