First study of radiation hardness of lead tungstate crystals at low temperatures
P. A. Semenov, A. V. Uzunian, A. M. Davidenko, A. A. Derevschikov, Y. M. Goncharenko, V. A. Kachanov, V. Y. Khodyrev, A. P. Meschanin, N. G. Minaev, V. V. Mocha… 展开作者
P. A. Semenov, A. V. Uzunian, A. M. Davidenko, A. A. Derevschikov, Y. M. Goncharenko, V. A. Kachanov, V. Y. Khodyrev, A. P. Meschanin, N. G. Minaev, V. V. Mochalov, Y. M. Melnick, A. V. Ryazantsev, A. N. Vasiliev, S. F. Burachas, M. S. Ippolitov, V. Manko, A. A. Vasiliev, A. V. Mochalov, R. Novotny, G. Tamulaitis
The electromagnetic calorimeter of PANDA at the FAIR facility will rely on an operation of lead tungstate (PWO) scintillation crystals at temperatures near -25 deg.C to provide sufficient resolution for photons in the energy range from 8 GeV down to 10 MeV. Radiation hardness of PWO crystals was studied at the IHEP (Protvino) irradiation facility in the temperature range from room temperature down to -25 deg.C. These studies have indicated a significantly different behaviour in the time evolution of the damaging processes well below room temperature. Different signal loss levels at the same dose rate, but at different temperatures were observed. The effect of a deep suppression of the crystal recovery process at temperatures below
0 deg.C has been seen.
In the context of the ClearMind project, we measured the scintillating properties, as induced from from gamma ray interactions, of today available PbWO4 crystal. We measured scintillation s yields and time constants by measuring the signal shape measured on a fast photo-multiplier and deconvoluting it from the instrumental effects. For the doped crystals at room temperature, we measured a fast scintillation component, with time constants of 2 ns, 55 percent of the total light yield, and a slow component of 6 ns. We observe a significant increase of the light yield for the slow component when t…
Eight production quality PbWO4 crystals of CMS have been irradiated in a 20 GeV/c proton beam up to fluences of 5.4E13cm-2. The damage recovery in these crystals has been followed for over a year. Comparative irradiations with 60Co photons have been performed on seven other crystals using a dose rate of 1 kGy/h. In proton irradiated crystals the light transmission band-edge shifts and the induced absorption length is proportional to the inverse of the 4th power of the wavelength. In gamma-irradiated crystals the band-edge does not shift but formation of absorption bands is seen clearly. The ab…
Commissioning of the large-scale lead tungstate scintillating calorimeter
Thomas Jefferson National Accelerator Facility(托马斯·杰斐逊国家加速器设施);University of North Carolina at Wilmington(北卡罗来纳大学温斯顿-塞勒姆分校);A. I. Alikhanian National Science Laboratory (Yerevan Physics Institute)(A.I.阿利哈尼扬国家科学实验室(埃里温物理研究所))
Fast hadrons have been observed to cause a cumulative damage in Lead Tungstate and LYSO crystals. The underlying mechanism has been proven to be the creation of fission tracks, which act as scattering centres, thus reducing the light collection efficiency. For calorimetry applications in an environment where large, fast hadron fluences are anticipated, predictions about damage in crystals are of great importance for making an informed choice of technology. In the study presented here, simulations using the FLUKA package have been performed on Lead Tungstate, LYSO and Cerium Fluoride, and their…
The Chinese large-area violet-light-sensitive silicon photodiode PIN is one of the candidates of the lead tungstate crystal detector readout component of the photon spectrometer in the large heavy ion collision experiment. The PIN diode was assembled with the lead tungstate crystal and the low-noise preamplifier into a complete detector unit. The beam test was carried out on the SPS accelerator at CERN. The energy resolution was measured with the electron beam energy ranging from 5 to 40 GeV. The summation correction method was discussed, and an excellent linearity of the nominal beam energy v…
Application of sequence learning for predicting radiation damage of the CMS electromagnetic calorimeter
Facultad de Ciencias, Universidad Nacional Autónoma de México(墨西哥国立自治大学理学院);Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México(墨西哥国立自治大学核科学研究所)
We measured a considerable increase of the emitted radiation by 120 GeV/c electrons in an axially oriented lead tungstate scintillator crystal, if compared to the case in which the sample was not aligned with the beam direction. This enhancement resulted from the interaction of particles with the strong crystalline electromagnetic field. The data collected at the external lines of CERN SPS were critically compared to Monte Carlo simulations based on the Baier Katkov quasiclassical method, highlighting a reduction of the scintillator radiation length by a factor of five in case of beam alignmen…
The 75,848 lead tungstate crystals in CMS experiment at the CERN Large Hadron Collider are used to measure the energy of electrons and photons produced in the proton-proton collisions. The optical transparency of the crystals degrades slowly with radiation dose due to the beam-beam collisions. The transparency of each crystal is monitored with a laser monitoring system that tracks changes in the optical properties of the crystals due to radiation from the collision products. Predicting the optical transparency of the crystals, both in the short-term and in the long-term, is a critical task for…
Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation
Future HEP experiments present stringent challenges to inorganic scintillators in both fast timing response and radiation tolerance. This paper reports recent progress in developing ultrafast inorganic scintillators with sub-ns decay time for future precision timing detectors and high-rate experiments. Performance of fast and ultrafast crystals with mass production capability are compared to CsI crystals which are used for the Mu2e calorimeter. Examples are LYSO:Ce, BaF2 and BaF2:Y, which are considered for Mu2e-II. Crystal radiation hardness against gamma-rays and hadrons is reported. Current…