The high intensity and high repetition rate of the European X-ray Free-Electron Laser, presently under construction in Hamburg, requires silicon sensors which can stand X-ray doses of up to 1 GGy for 3 years of operation at high bias voltage. Within the AGIPD Collaboration the X-ray-radiation damage in MOS Capacitors and Gate-Controlled Diodes fabricated by four vendors on high-ohmic n-type silicon with two crystal orientations and dif- ferent technological parameters, has been studied for doses between 1 kGy and 1 GGy. The extracted values of oxide-charge and surface-current densi- ties have been used in TCAD simulations, and the layout and technological parameters of the AGIPD pixel sensor optimized. It is found that the op- timized layout for high X-ray doses is significantly different from the one for non-irradiated sensors. First sensors and test structures have been de-livered in early 2013. Measurement results for X-ray doses of 0 to 10 MGy and their comparison to simulations are presented. They demonstrate that the optimization has been successful and that the sensors fulfill the required specifications.
The Adaptive Gain Integrating Pixel Detector (AGIPD) is an x-ray imager, custom designed for the European x-ray Free-Electron Laser (XFEL). It is a fast, low noise integrating detector, with an adaptive gain amplifier per pixel. This has an equivalent noise of less than 1 keV when detecting single photons and, when switched into another gain state, a dynamic range of more than 10$^4$ photons of 12 keV. In burst mode the system is able to store 352 images while running at up to 6.5 MHz, which is compatible with the 4.5 MHz frame rate at the European XFEL. The AGIPD system was installed and comm…
The European X-ray Free Electron Laser (XFEL) is a new research facility currently under construction in Hamburg, Germany. With a pulse length of less than 100 fs and an extremely high luminosity of 27000 flashes per second the European XFEL will have a unique time structure that demands the development of new detectors tailored to the requirements imposed by the experiments while complying with the machine specific operation parameters. The Adaptive Gain Integrating Pixel Detector (AGIPD) is one response to the need for large 2D detectors, able to cope with the 4.5 MHz frame rate, as well as …
A systematic experimental study of the main challenges for silicon-pixel sensors at the European XFEL is presented. The high instantaneous density of X-rays and the high repetition rate of the XFEL pulses result in signal distortions due to the plasma effect and in severe radiation damage. The main parameters of X-ray-radiation damage have been determined and their impact on p+n sensors investigated. These studies form the basis of the optimized design of a pixel-sensor for experimentation at the European XFEL.
We present experimental data illustrating how heat load affects the performance of a cryogenically cooled monochromator under intense X-ray Free-Electron Laser pulses. The measurements are in good agreement with a depth-uniform model of X-ray dynamical diffraction taking beam absorption and heat deformation of the crystals into account.
For experiments at the European X-Ray Free-Electron Laser (XFEL) the Adaptive Gain Integrating Pixel Detector (AGIPD) is under development. The particular requirements for the detector are a high dynamic range of 0, 1 - to more than 10E4 12.4 keV photons per pixel within an XFEL pulse duration of < 100 fs, and a radiation tolerance of doses up to 1 GGy for 3 years of operation. The detector will have 1024 x 1024 p+ pixels with a pixel size of 200 um x 200 um and will be manufactured on 500 um thick n-type silicon. The design value for the operating voltage is 500 V, however, for special applic…
The LUXE experiment aims at studying strong-field QED in electron-laser and photon-laser interactions, with the $16.5$ GeV electron beam of the European XFEL and a laser beam with power of up to $350$ TW. The strong-field QED processes are expected to have production rates ranging from $10^{-3}$ to $10^9$ per $10$ Hz bunch crossing. Additionally, these measurements must be performed in a low-energy, high-radiation background. The LUXE experiment will utilise various detector technologies to overcome these challenges.
Gotthard-II is a 1-D microstrip detector specifically developed for the European X-ray Free-Electron Laser. It will not only be used in energy dispersive experiments but also as a beam diagnostic tool with additional logic to generate veto signals for the other 2-D detectors. Gotthard-II makes use of a silicon microstrip sensor with a pitch of either 50 μm or 25 μm and with 1280 or 2560 channels wire-bonded to adaptive gain switching readout chips. Built-in analog-to-digital converters and digital memories will be implemented in the readout chip for a continuous conversion and storage of frame…
A new, modular toolkit for creating simulations of 2D X-ray pixel detectors, X-CSIT (X-ray Camera SImulation Toolkit), is being developed. The toolkit uses three sequential simulations of detector processes which model photon interactions, electron charge cloud spreading with a high charge density plasma model and common electronic components used in detector readout. In addition, because of the wide variety in pixel detector design, X-CSIT has been designed as a modular platform so that existing functions can be modified or additional functionality added if the specific design of a detector d…
The LUXE experiment aims at studying high-field QED in electron-laser and photon-laser interactions, with the 16.5 GeV electron beam of the European XFEL and a laser beam with power of up to 350 TW. The experiment will measure the spectra of electrons and photons in non-linear Compton scattering where production rates in excess of $10^9$ are expected per 1 Hz bunch crossing. At the same time positrons from pair creation in either the two-step trident process or the Breit-Wheeler process will be measured, where the expected rates range from $10^{-3}$ to $10^3$ per bunch crossing, depending on t…
The European X-ray Free Electron Laser (XFEL), currently being constructed in Hamburg and planning to be operational in 2017 for users, will deliver 27,000 fully coherent, high brilliance X-ray pulses per second with duration less than 100 fs. The unique features of the X-ray beam pose major challenges for detectors used at the European XFEL for imaging experiments, in particular a radiation tolerance of silicon sensors for doses up to 1 GGy for 3 years of operation at an operating voltage above 500 V. One of the detectors under development at the European XFEL is the Adaptive Gain Integrating…
Gotthard-II is a charge-integrating microstrip detector developed for experiments and diagnostics at free-electron lasers using hard X-rays of 5 keV - 20 keV. Thanks to its excellent single photon sensitivity, large dynamic range as well as high frame rate of 4.5 MHz in burst mode, its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), beam diagnostics, as well as veto signal generation for pixel detectors. The Gotthard-II ASIC has been designed and fabricated using UMC-110 nm technology. The final ASIC…
The European XFEL is an extremely brilliant Free Electron Laser Source with a very demanding pulse structure: trains of 2700 X-Ray pulses are repeated at 10 Hz. The pulses inside the train are spaced by 220 ns and each one contains up to $10^{12}$ photons of 12.4 keV, while being $\le 100$ fs in length. AGIPD, the Adaptive Gain Integrating Pixel Detector, is a hybrid pixel detector developed by DESY, PSI, and the Universities of Bonn and Hamburg to cope with these properties. It is a fast, low noise integrating detector, with single photon sensitivity (for $\text{E}_γ \ge 6$ keV) and a large d…
The LUXE experiment (Laser Und XFEL Experiment) is a new experiment in planning at DESY Hamburg using the electron beam of the European XFEL (Eu.XFEL). LUXE is intended to study collisions between a high-intensity optical laser and up to 16.5 GeV electrons from the Eu.XFEL electron beam, or, alternatively, high-energy secondary photons. The physics objective of LUXE are processes of Quantum Electrodynamics (QED) at the strong-field frontier, where QED is non-perturbative. The design of the experimental setup and the different detectors are presented.
The LUXE experiment aims at studying high-field QED in electron-laser and photon-laser interactions, with the 16.5 GeV electron beam of the European XFEL and a laser beam with power of up to 350 TW. The experiment will measure the spectra of electrons and photons in non-linear Compton scattering where production rates in excess of $10^9$ are expected per 1 Hz bunch crossing. At the same time positrons from pair creation in either the two-step trident process or the Breit--Wheeler process will be measured, where the expected rates range from $10^{-3}$ to $10^4$ per bunch crossing, depending on …
The LUXE experiment aims at studying high-field QED in electron-laser and photon-laser interactions, with the 16.5 GeV electron beam of the European XFEL and a laser beam with power of up to 350 TW. The experiment will measure the spectra of electrons, positrons and photons in expected ranges of 10$^{-3}$ to 10$^9$ per 1 Hz bunch crossing, depending on the laser power and focus. These measurements have to be performed in the presence of low-energy high radiation-background. To meet these challenges, for high-rate electron and photon fluxes, the experiment will use Cherenkov radiation detectors…
A silicon pixel detector with fine pitch size of 19x19 um, developed base on SOI (silicon on insulator) technology, was tested under the illumination of infrared laser pulses. As an alternative way to particle beam tests, the laser pulses were tuned to very short duration and small transverse profile to simulate the tracks of MIPs (minimum ionization particles) in silicon. Hit cluster sizes were measured with focused laser pulses propagating through the SOI detector perpendicular to its surface and most of the induced charge was found to be collected inside the seed pixel. For the first time, …
The European X-ray Free Electron Laser (EuXFEL) is a research facility providing spatially coherent X-ray flashes in the energy range from 0.25keV to 25keV of unprecedented brilliance and with unique time structure: X-ray pulses with a 4.5 MHz repetition rate arranged in trains with 2700 pulses every 100 ms. The facility operates three photon beamlines called SASE 1, SASE 2 and SASE 3. Each of the beamlines is hosting two scientific experiments. The SASE 1 beamline started its user operation in September 2017, followed by successful first lasing at the SASE 2 beamline in May 2018. Early user e…
Building the European Spallation Source (ESS), the most powerful neutron source in the world, requires significant technological advances at most fronts of instrument component design. Detectors are not an exception. The existing implementations at current neutron scattering facilities are at their performance limits and sometimes barely cover the scientific needs. At full operation the ESS will yield unprecedented neutron brilliance. This means that one of the most challenging aspects for the new detector designs is the increased rate capability and in particular the peak instantaneous rate c…
The ePix detector family provides multiple variants of hybrid pixel detectors to support a wide range of applications at free electron laser facilities. We present the results of a systematic study of the influence of radiation induced damage on the performance and lifetime of an ePix100a detector module using a direct attenuated beam of the EuXFEL at 9 keV photon energy and an average power of 10 $μ$W. An area of 20 x 20 pixels was irradiated with an average photon flux of approx. 7 x $10^{9}$ photons/s to a dose of approximately 760$\pm$65 kGy at the location of the Si/SiO$_2$ interfaces in …
First measurements are presented from a newly commissioned two-photon absorption (TPA) setup at Nikhef. The characterisation of the various components of the system is discussed. Two planar silicon sensors, one being electron collecting and one hole collecting, are characterised with detailed measurements of the charge collection and time resolution. The TPA spot is determined to have a radius of 0.975(11) $μ\text{m}$ and length of 23.8 $μ\text{m}$ in silicon. The trigger time resolution of the system is shown to be maximally 30.4 ps. For both sensors, uniform charge collection is observed ove…
We propose the use of germanium-on-silicon technology for indirect time-of-flight based three-dimensional sensing, and demonstrate a novel lock-in pixel featuring high quantum efficiency and large frequency bandwidth. Compared to silicon pixels, germanium-on-silicon pixels simultaneously maintain a high quantum efficiency and a high demodulation contrast deep into GHz frequency regime, which enable consistently superior depth accuracy in both indoor and outdoor scenarios. Physical model, numerical simulation, device fabrication and characterization, system performance comparison, and laser saf…
We performed an experimental study to determine the pixel recovery time of various Multi Pixel Photon Counters (MPPCs) in order to characterize their rate capability and double-hit resolution. The recovery time constant and its dependence on the operating voltage has been evaluated by measuring the photosensor response to two consecutive laser pulses with varying relative time differences of a few ns (2-3 ns) up to some 100 ns using a waveform analysis technique. A Monte Carlo simulation tool is being developed to model the MPPC recovery process and interpret experimental data. In this context…
The European XFEL, currently under construction, will produce a coherent X-ray pulse every 222 ns in pulse trains of up to 2700 pulses. In conjunction with the fast 2D area detectors currently under development, it will be possible to perform X-ray Photon Correlation Spectroscopy (XPCS) experiments on sub-microsecond timescales with non-ergodic systems. A case study for the Adaptive Gain Integrating Pixel Detector (AGIPD) at the European XFEL employing the intensity autocorrelation technique was performed using the detector simulation tool HORUS. As optimum results from XPCS experiments are ob…
The European X-ray Free Electron Laser (XFEL.EU) is currently being commissioned in Schenefeld, Germany. From 2017 onwards it will provide spatially coherent X-rays of energies between 0.25\,keV and 25\,keV with a unique timing structure. One of the detectors foreseen at XFEL.EU for the soft X-ray regime (energies below 6\,keV) is a quasi column-parallel readout FastCCD developed by Lawrence Berkeley National Lab (LBNL) specifically for the XFEL.EU requirements. Its sensor has 1920$\times$960 pixels of 30\,$μ$m $\times$30\,$μ$m size with a beam hole in the middle of the sensor. The camera can …
The European X-ray Free Electron Laser is a high-intensity X-ray light source currently being constructed in the area of Hamburg, that will provide spatially coherent X-rays in the energy range between $0.25\,\mathrm{keV}$ and $25\,\mathrm{keV}$. The machine will deliver $10\,\mathrm{trains/s}$, consisting of up to $2700\,\mathrm{pulses}$, with a $4.5\,\mathrm{MHz}$ repetition rate. The LPD, DSSC and AGIPD detectors are being developed to provide high dynamic-range Mpixel imaging capabilities at the mentioned repetition rates. A consequence of these detector characteristics is that they genera…
The spectrum of laser-plasma generated X-rays is very important, it characterizes electron dynamics in plasma and is basic for applications. However, the accuracies and efficiencies of existing methods to diagnose the spectrum of laser-plasma based X-ray pulse are not very high, especially in the range of several hundred keV. In this study, a new method based on electron tracks detection to measure the spectrum of laser-plasma produced X-ray pulses is proposed and demonstrated. Laser-plasma generated X-rays are scattered in a multi-pixel silicon tracker. Energies and scattering directions of C…
This paper presents the results of the characterisation of a pixel sensor manufactured in OKI 0.2 micron SOI technology integrated on a high-resistivity substrate, and featuring several pixel cell layouts for charge collection optimisation. The sensor is tested with short IR laser pulses, X-rays and 200 GeV pions. We report results on charge collection, particle detection efficiency and single point resolution.
We demonstrate X-ray phase contrast microscopy performed at the European X-ray Free-Electron Laser sampled at 1.128 MHz rate. We have applied this method to image stochastic processes induced by an optical laser incident on water-filled capillaries with micrometer scale spatial resolution. The generated high speed water jet, cavitation formation and annihilation in water and glass, as well as glass explosions are observed. The comparison between XFEL and previous synchrotron MHz microscopy shows the superior contrast and spatial resolution at the XFEL over the synchrotron. This work opens up n…
The superposition of several optical beams with large mutual angles results in sub-micrometer periodic patterns with a complex intensity, phase and polarization structure. For high-resolution imaging thereof, one often employs optical super-resolution methods such as scanning nano-particle imaging. Here, we report that by using a conventional arrayed image sensor in combination with 2D Fourier analysis, the periodicities of light fields much smaller than the pixel size can be resolved in a simple and compact setup, with a resolution far beyond the Nyquist limit set by the pixel size. We demons…
This paper presents the design and test results of a prototype monolithic pixel sensor manufactured in deep-submicron fully-depleted Silicon-On-Insulator (SOI) CMOS technology. In the SOI technology, a thin layer of integrated electronics is insulated from a (high-resistivity) silicon substrate by a buried oxide. Vias etched through the oxide allow to contact the substrate from the electronics layer, so that pixel implants can be created and a reverse bias can be applied. The prototype chip, manufactured in OKI 0.15 micron SOI process, features both analog and digital pixels on a 10 micron pit…
X-ray Free Electron Lasers (XFELs) have been proven to generate short and powerful radiation pulses allowing for a wide class of novel experiments. If an XFEL facility supports the generation of two X-ray pulses with different wavelengths and controllable delay, the range of possible experiments is broadened even further to include X-ray-pump/X-ray-probe applications. In this work we discuss the possibility of applying a simple and cost-effective method for producing two-color pulses at the SASE3 soft X-ray beamline of the European XFEL. The technique is based on the installation of a magnetic…
Experiments at the European X-ray Free Electron Laser (XFEL) require silicon pixel sensors which can withstand X-ray doses up to 1 GGy. For the investigation of X-ray radiation damage up to these high doses, MOS capacitors and gate-controlled diodes built on high resistivity n-doped silicon with crystal orientations <100> and <111> produced by two vendors, CiS and Hamamatsu, have been irradiated with 12 keV X-rays at the DESY DORIS III synchrotron light source. Using capacitance/conductance-voltage, current-voltage and thermal dielectric relaxation current measurements, the surface densities o…
A monolithic pixel sensor in deep-submicron Silicon-On-Insulator (SOI) CMOS technology has been designed, manufactured and characterised. This technology is of significant interest for applications in particle tracking and imaging. The prototype chip features pixels of 10 micron pitch arrayed in two analog sections and one digital section with a comparator and a latch integrated in each pixel. The prototype response has been tested with infrared lasers and with the 1.35 GeV electron beam extracted from the injection booster at the LBNL Advanced Light Source. Results from irradiation tests with…
For operation at the High Luminosity Large Hadron Collider (LHC), the ATLAS experiment is building a new all-silicon inner tracker (ITk). The production and testing of thousands of silicon pixel and strip modules is required to cover the estimated 180 m$^{2}$ of the total surface area. A compact, affordable and robust module characterization system is required for in-situ testing prior any test beam campaign or installation. A test bench setup based on an infrared laser was developed at IJCLab, allowing also for the use of micro-metric precision scanning with a radioactive source. A detailed s…
The LUXE experiment (Laser Und XFEL Experiment) is a new experiment in planning at DESY Hamburg using the electron beam of the European XFEL. LUXE is intended to study collisions between a high-intensity optical laser and up to 16.5 GeV electrons from the Eu.XFEL electron beam, or, alternatively, high-energy secondary photons. The physics objective of LUXE are processes of Quantum Electrodynamics (QED) at the strong-field frontier, where QED is non-perturbative. This manifests itself in the creation of physical electron-positron pairs from the QED vacuum. LUXE intends to measure the positron p…
Dynamic x-ray studies may reach temporal resolutions limited by only the x-ray pulse duration if the detector is fast enough to segregate synchrotron pulses. An analog integrating pixel array detector with in-pixel storage and temporal resolution of around 150 ns, sufficient to isolate pulses, is presented. Analog integration minimizes count-rate limitations and in-pixel storage captures successive pulses. Fundamental tests of noise and linearity as well as high-speed laser measurements are shown. The detector resolved individual bunch trains at the Cornell High Energy Synchrotron Source (CHES…
Laser Und XFEL Experiment (LUXE), is a new High Energy and Laser Physics experiment planned to be installed in DESY. It will study the interactions of a very-intense Laser beam with the high-energy, high-quality electron beams from the European XFEL accelerator, to measure characteristics of non-perturbative quantum electrodynamics.
Single photon sensitivity is an important property of certain detection systems. This work investigated the single photon sensitivity of the Adaptive Gain Integrating Pixel Detector (AGIPD) and its dependence on possible detector noise values. Due to special requirements at the European X-ray Free Electron Laser (XFEL) the AGIPD finds the number of photons absorbed in each pixel by integrating the total signal. Photon counting is done off line on a thresholded data set. It was shown that AGIPD will be sensitive to single photons of 8 keV energy or more (detection efficiency $\gg$ 50%, less tha…
In this work we investigated a method to determine time walk in an active silicon pixel sensor prototype using Edge-TCT with infrared laser charge injection. Samples were investigated before and after neutron irradiation to 5e14 neq/cm2. Threshold, noise and calibration of the analogue front end were determined with external charge injection. A spatially sensitive measurement of collected charge and time walk was carried out with Edge-TCT, showing a uniform charge collection and output delay in pixel centre. On pixel edges charge sharing was observed due to finite beam width resulting in small…
Electrons are emerging as a strong complement to X-rays for diffraction based studies. In this paper we investigate the performance of a JUNGFRAU detector with 320 um thick silicon sensor at a pulsed electron source. Originally developed for X-ray detection at free electron lasers, JUNGFRAU features a dynamic range of 120 MeV/pixel (implemented with in-pixel gain switching) which translated to about 1200 incident electrons per pixel and frame in the MeV region. We preset basic characteristics such as energy deposited per incident particle, resulting cluster size and spatial resolution along wi…
Monolithic active pixel sensors (MAPS) are now well established as a technology for tracking charged particles, especially when low material budget is desirable. For such applications, sensors focus on spatial resolution and pixels with digital output or modest charge measurement ability are well suited. Within the European Union STRONG-2020 project, which focuses on experiments using hadrons, the TIIMM (Tracking and Ions Identifications with Minimal Material budget) joint research activity intends to expand granular MAPS capacity to energy-loss (ΔE) measurement for ion species identification.…
The LUXE experiment (Laser Und XFEL Experiment) is a new experiment in planning at DESY Hamburg using the electron beam of the European XFEL. At LUXE, the aim is to study collisions between a high-intensity optical laser and up to $16.5\,$GeV electrons from the Eu.XFEL electron beam, or, alternatively, high-energy secondary photons. The physics objectives of LUXE are to measure processes of Quantum Electrodynamics (QED) at the strong-field frontier, where QED is non-perturbative. This manifests itself in the creation of physical electron-positron pairs from the QED vacuum. LUXE intends to meas…
This Letter of Intent describes LUXE (Laser Und XFEL Experiment), an experiment that aims to use the high-quality and high-energy electron beam of the European XFEL and a powerful laser. The scientific objective of the experiment is to study quantum electrodynamics processes in the regime of strong fields. High-energy electrons, accelerated by the European XFEL linear accelerator, and high-energy photons, produced via Bremsstrahlung of those beam electrons, colliding with a laser beam shall experience an electric field up to three times larger than the Schwinger critical field (the field at wh…
The X-ray free-electron lasers that became available during the last decade, like the European XFEL (EuXFEL), place high demands on their instrumentation. Especially at low photon energies below $1\,\text{keV}$, detectors with high sensitivity, and consequently low noise and high quantum efficiency, are required to enable facility users to fully exploit the scientific potential of the photon source. A 1-Megapixel pnCCD detector with a $1024\times 1024$ pixel format has been installed and commissioned for imaging applications at the Nano-Sized Quantum System (NQS) station of the Small Quantum S…
The European X-ray Free Electron Laser (XFEL.EU) will provide every 0.1 s a train of 2700 spatially coherent ultrashort X-ray pulses at 4.5 MHz repetition rate. The Small Quantum Systems (SQS) instrument and the Spectroscopy and Coherent Scattering instrument (SCS) operate with soft X-rays between 0.5 keV - 6keV. The DEPFET Sensor with Signal Compression (DSSC) detector is being developed to meet the requirements set by these two XFEL.EU instruments. The DSSC imager is a 1 mega-pixel camera able to store up to 800 single-pulse images per train. The so-called ladder is the basic unit of the DSS…
The European X-ray Free Electron Laser (XFEL) will deliver 27000 fully coherent, high brilliance X-ray pulses per second each with a duration below 100 fs. This will allow the recording of diffraction patterns of single molecules and the study of ultra-fast processes. One of the detector systems under development for the XFEL is the Adaptive Gain Integrating Pixel Detector (AGIPD), which consists of a pixel array with readout ASICs bump-bonded to a silicon sensor with pixels of 200 μm \times 200 μm. The particular requirements for the detector are a high dynamic range (0, 1 up to 10E5 12 keV p…
The LUXE experiment (LASER Und XFEL Experiment) is a new experiment in planning at DESY Hamburg using the electron beam of the European XFEL. LUXE is intended to study collisions between a high-intensity optical laser and 16.5 GeV electrons from the XFEL electron beam, as well as collisions between the optical LASER and high-energy secondary photons. The physics objective of LUXE are processes of Quantum Electrodynamics (QED) at the strong-field frontier, where the electromagnetic field of the laser is above the Schwinger limit. In this regime, QED is non-perturbative. This manifests itself in…
Several charge integrating CMOS pixel front-ends utilizing charge removal techniques have been fabricated to extend dynamic range for x-ray diffraction applications at synchrotron sources and x-ray free electron lasers (XFELs). The pixels described herein build on the Mixed Mode Pixel Array Detector (MM-PAD) framework, developed previously by our group to perform high dynamic range imaging. These new pixels boast several orders of magnitude improvement in maximum flux over the MM-PAD, which is capable of measuring a sustained flux in excess of 10$^{8}$ x-rays/pixel/second while maintaining sen…
Femtosecond transient soft X-ray Absorption Spectroscopy (XAS) is a very promising technique that can be employed at X-ray Free Electron Lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here we present a dedicated setup for soft X-rays available at the Spectroscopy & Coherent Scattering (SCS) instrument at the European X-ray Free Electron Laser (EuXFEL). It consists of a beam-splitting off-axis zone plate (BOZ) used in transmission to create three copies of the incoming beam, which are used to measure the transmitted intensity through the excited and u…
We present the first characterization results of Timespot1, an ASIC designed in CMOS 28 nm technology, featuring a $32 \times 32$ pixel matrix with a pitch of $55 ~ μm$. Timespot1 is the first small-size prototype, conceived to readout fine-pitch pixels with single-hit time resolution below $50 ~ ps_\text{rms}$ and input rates of several hundreds of kilohertz per pixel. Such experimental conditions will be typical of the next generation of high-luminosity collider experiments, from the LHC run5 and beyond. Each pixel of the ASIC includes a charge amplifier, a discriminator, and a Time-to-Digit…
The European X-ray Free Electron Laser (XFEL.EU) will provide unprecedented peak brilliance and ultra-short and spatially coherent X-ray pulses in an energy range of 0.25 to 25 keV . The pulse timing structure is unique with a burst of 2700 pulses of 100 fs length at a temporal distance of 220 ns followed by a 99.4 ms gap. To make optimal use of this timing structure and energy range a great variety of detectors are being developed for use at XFEL.EU, including 2D X-ray imaging cameras that are able to detect images at a rate of 4.5 MHz, provide dynamic ranges up to 10$^5$ photons per pulse pe…