arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2105.02178physics.ins-det
收藏

利用硅跟踪器诊断超短X射线脉冲

Diagnostics for ultrashort X-ray pulses using silicon trackers

Jiaxing Wen, Minghai Yu, Yuchi Wu, Ming Zeng, Bo Zhang, Jirong Cang, Yuge Zhang, Ge Ma, Yue Yang, Wenbo Mo, Zongqing Zhao

摘要:

激光等离子体产生的X射线光谱是非常重要的,它表征了等离子体中的电子动力学,是应用的基础。然而,现有的激光等离子体基X射线脉冲光谱诊断方法的精度和效率都不高,特别是在几百keV的范围内。本文提出并论证了一种基于电子径迹探测的激光等离子体产生的X射线脉冲光谱测量方法。激光等离子体产生的X射线在多像素硅跟踪器中散射。从探测器的响应中可以提取康普顿电子的能量和散射方向,从而可以重建X射线的光谱。模拟结果表明,对于12 $\rm μ$ m像素间距和500 $\rm μ$ m耗尽区厚度的绝缘体上硅像素探测器,该方法对200 ~ 550 keV X射线的能量分辨率约为20%.还显示了基于Timepix 3探测器的原理验证实验的结果。

英文摘要:

The spectrum of laser-plasma generated X-rays is very important, it characterizes electron dynamics in plasma and is basic for applications. However, the accuracies and efficiencies of existing methods to diagnose the spectrum of laser-plasma based X-ray pulse are not very high, especially in the range of several hundred keV. In this study, a new method based on electron tracks detection to measure the spectrum of laser-plasma produced X-ray pulses is proposed and demonstrated. Laser-plasma generated X-rays are scattered in a multi-pixel silicon tracker. Energies and scattering directions of Compton electrons can be extracted from the response of the detector, and then the spectrum of X-rays can be reconstructed. Simulations indicate that the energy resolution of this method is approximately 20% for X-rays from 200 to 550 keV for a silicon-on-insulator pixel detector with 12 $\rm μ$m pixel pitch and 500 $\rm μ$m depletion region thickness. The results of a proof-of-principle experiment based on a Timepix3 detector are also shown.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑