ATLAS液氩电磁量能器的响应均匀性

Response Uniformity of the ATLAS Liquid Argon Electromagnetic Calorimeter

M. Aharrouche, J. Colas, L. Di Ciaccio, M. El Kacimi, O. Gaumer, M. Gouanere, D. Goujdami, R. Lafaye, S. Laplace, C. Le Maner, L. Neukermans, P. Perrodo, L. Pog… 展开作者

M. Aharrouche, J. Colas, L. Di Ciaccio, M. El Kacimi, O. Gaumer, M. Gouanere, D. Goujdami, R. Lafaye, S. Laplace, C. Le Maner, L. Neukermans, P. Perrodo, L. Poggioli, D. Prieur, H. Przysiezniak, G. Sauvage, I. Wingerter-Seez, R. Zitoun, F. Lanni, L. Lu, H. Ma, S. Rajago palan, H. Takai, A. Belymam, D. Benchekroun, M. Hakimi, A. Hoummada, Y. Gao, R. Stroynowsk, M. Aleksa, T. Carli, P. Fassnacht, F. Gianotti, L. Hervas, W. Lampl, J. Collot, J. Y. Ho stachy, F. Ledroit-Guillon, F. Malek, P. Martin, S. Viret, M. Leltchouk, J. A. Parsons, S. Simion, F. Barreiro, J. Del Peso, L. Labarga, C. Oliver, S. Rodier, P. Barrillon, C. Bench ouk, F. Djama, F. Hubaut, E. Monnier, P. Pralavorio, D. Sauvage, C. Serfon, S. Tisserant, J. Toth, D. Banfi, L. Carminati, D. Cavalli, G. Costa, M. Delmastro, M. Fanti, L. Mandell, M. Mazzanti, G. F. Tartarelli, K. Kotov, A. Maslennikov, G. Pospelov, Yu. Tikhonov, C. Bourdarios, L. Fayard, D. Fournier, L. Iconomidou-Fayard, M. Kado, G. Parrour, P. Puzo, D. Rousseau, R. Sacco, L. Serin, G. Unal, D. Zerwas, B. Dekhissi, J. Derkaoui, A. El Kharrim, F. Maaroufi, W. Cleland, D. Lacour, B. Laforge, I. Nikolic-Audit, Ph. Schwemling, H. Gha zlane, R. Cherkaoui El Moursli, A. Idrissi Fakhr-Eddine, M. Boonekamp, N. Kerschen, B. Man soulie, P. Meyer, J. Schwindlingy, B. Lund-Jensen

摘要:

完成了ATLAS电磁式液氩量能器模块的组装和插入低温恒温器的工作。在生产期间,四个桶和三个端盖模块暴露于测试束,以评估其性能,确定生产质量和再现性,并仔细检查从读出和校准电子设备到信号和能量重建的完整能量重建链。还可以检查热量计的完整蒙特卡罗模拟。对该方法的均匀性、分辨率和常数项的提取进行了分析。典型的非均匀性为0.5%和典型的全球常数项为0.6%的桶和端盖模块进行测量。

英文摘要:

The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑