The purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires from a room-temperature environment (300 K) through the cryostat walls to the calorimeters cells (89 K) while maintaining the electrical and cryogenic integrity of the system. The feedthrough wiring and filters operate at a maximum high voltage of 2.5 kV without danger of degradation by corona discharges or radiation at the Large Hadron Collider.
Voltages above a hundred kilo-volt will be required to generate the drift field of future very large liquid Argon Time Projection Chambers. The most delicate component is the feedthrough whose role is to safely deliver the very high voltage to the cathode through the thick insulating walls of the cryostat without compromising the purity of the argon inside. This requires a feedthrough that is typically meters long and carefully designed to be vacuum tight and have small heat input. Furthermore, all materials should be carefully chosen to allow operation in cryogenic conditions. In addition, el…
We present the optical data links for the ATLAS liquid argon calorimeter. The current status of the vertical cavity surface emitting laser failures, the up-to-date results in searching for the failure cause, experiences gained in the searching process, possible backup plans for the optical transmitters and the lessons learned are also discussed.
The high-luminosity phase of the Large Hadron Collider will provide 5-7 times greater luminosities than assumed in the original detector design. An improved trigger system requires an upgrade of the readout electronics of the ATLAS Liquid Argon Calorimeter. Concepts for the future readout of the 182,500 calorimeter cells at 40-80 MHz and 16-bit dynamic range and the developments of radiation-tolerant, low-noise, low-power, and high-bandwidth front-end electronic components, including preamplifiers and shapers, 14-bit ADCs, and 10-Gb/s laser diode array drivers, are presented in this paper.
Design, construction, commissioning and long term operational experience with the D0 Uranium/Liquid Argon calorimeter
D 0实验设计于20世纪80年代中期,并于1992年至2011年在费米实验室pp对撞机上运行。我描述了铀-液氩量热计及其读出电子,其在20世纪90年代后期进行了升级,以处理升级后的Tevatron在2001-2011年的第二次运行期间的更高亮度。我总结了20年来保持热量计的数据采集。我进一步描述了在此期间出现的一些问题,包括不同类型的噪声和只在中央量热计中看到的异常高压电流。
A Liquid-argon Trigger Digitizer Board (LTDB) is being developed to upgrade the ATLAS Liquid Argon Calorimeter Phase-I trigger electronics. The LTDB located at the front end needs to obtain the clock signals and be configured and monitored remotely from the back end. A clock and control system is being developed for the LTDB and the major functions of the system have been evaluated. The design and evaluation of the clock and control system are presented in this paper.
We have been developing a serializer application-specific integrated circuit (ASIC) based on a commercial 0.25-μm silicon-on-sapphire (SOS) CMOS technology for the ATLAS liquid argon calorimeter front-end electronics upgrade. The first prototype, a 5 Gbps 16:1 serializer has been designed, fabricated, and tested in lab environment and in a 200 MeV proton beam. The test results indicate that the first prototype meets the design goals. The second prototype, a double-lane, 8 Gbps per lane serializer is under development. The post-layout simulation indicates that 8 Gbps is achievable. In this pape…
In this paper, we present the design and test results of LOCx2, a transmitter ASIC for the ATLAS Liquid Argon Calorimeter trigger upgrade. LOCx2 consists of two channels and each channel encodes ADC data with an overhead of 14.3% and transmits serial data at 5.12 Gbps with a latency of less than 27.2 ns. LOCx2 is fabricated with a commercial 0.25-um Silicon-on-Sapphire CMOS technology and is packaged in a 100-pin QFN package. The power consumption of LOCx2 is about 843 mW.
Two optical data link data transmission Application Specific Integrated Circuits (ASICs), the baseline and its backup, have been designed for the ATLAS Liquid Argon (LAr) Calorimeter Phase-I trigger upgrade. The latency of each ASIC and that of its corresponding receiver implemented in a back-end Field-Programmable Gate Array (FPGA) are critical specifications. In this paper, we present the latency measurements and simulation of two ASICs. The measurement results indicate that both ASICs achieve their design goals and meet the latency specifications. The consistency between the simulation and …
A prototype optical-link board has been developed for the ATLAS Liquid Argon Calorimeter Phase-2 upgrade. The board consists of 24 lpGBT chips and 8 VTRx+ modules and demonstrates the full optical link design of the future front-end board. The board has 22 simplex optical links to transmit detector data, which are emulated in FPGAs and injected through 6 FMC connectors, to the off-detector electronics. The board implements 2 duplex optical links for clocks, control, and monitoring with redundant design to improve the system reliability. Data transmission and all redundant designs have been ver…
A serializer ASIC and a VCSEL driver ASIC are needed for the front-end optical data transmission in the ATLAS liquid argon calorimeter readout phase-I upgrade. The baseline ASICs are the serializer LOCx2 and the VCSEL driver LOCld, designed in a 0.25-μm Silicon-on-Sapphire (SoS) CMOS technology and consumed 843 mW and 320 mW, respectively. Based on a 130-nm CMOS technology, we design two pin-to-pin-compatible backup ASICs, LOCx2-130 and LOCld-130. Their power consumptions are much lower then of their counterparts, whereas other performance, such as the latency, data rate, and radiation toleran…
We present the procedures and results of the quality control tests for the front-end optical link components in the ATLAS Liquid Argon Calorimeter Phase-1 upgrade. The components include a Vertical-Cavity Surface-Emitting Laser (VCSEL) driver ASIC LOCld, custom optical transmitter/transceiver modules MTx/MTRx, and a transmitter ASIC LOCx2. LOCld, MTx, and LOCx2 each contain two channels with the same structure, while MTRx has a transmitter channel and a receiver channel. Each channel is tested at 5.12 Gbps. A total of 5341 LOCld chips, 3275 MTx modules, 797 MTRx modules, and 3198 LOCx2 chips a…
The readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider requires a radiation-hard ADC. The design of a radiation-hard dual-channel 12-bit 40 MS/s pipeline ADC for this use is presented. The design consists of two pipeline A/D channels each with four Multiplying Digital-to-Analog Converters followed by 8-bit Successive-Approximation-Register analog-to-digital converters. The custom design, fabricated in a commercial 130 nm CMOS process, shows a performance of 67.9 dB SNDR at 10 MHz for a single channel at 40 MS/s, with a latency of 87.5 ns (to f…
This paper presents several component prototypes towards a low-latency, small-form-factor optical link designed for the ATLAS Liquid Argon Calorimeter Phase-I trigger upgrade. A prototype of the custom-made dual-channel optical transmitter module, the Miniature optical Transmitter (MTx), with separate transmitter optical sub-assemblies (TOSAs) has been demonstrated at data rates up to 8 Gbps per channel. A Vertical-Cavity Surface-Emitting Laser (VCSEL) driver ASIC has been developed and is used in the current MTx prototypes. A serializer ASIC prototype, operating at up to 8 Gbps per channel, h…
High voltage breakdown in liquid argon is an important concern in the design of liquid argon time projection chambers, which are often used as neutrino and dark matter detectors. We have made systematic measurements of breakdown voltages in liquid argon along insulators surrounding negative rod electrodes where the breakdown is initiated at the anode. The measurements were performed in an open cryostat filled with commercial grade liquid argon exposed to air, and not the ultra-pure argon required for electron drift. While not addressing all high voltage concerns in liquid argon, these measurem…
The liquid argon ionization current in a sampling calorimeter cell can be analyzed to determine the energy of detected particles. In practice, experimental artifacts such as pileup and electronic noise make the inference of energy from current a difficult process. The beam intensity of the Large Hadron Collider will be significantly increased during the Phase-II long shut down of 2025-2027. Signal processing techniques that are used to extract the energy of detected particles in the ATLAS detector will suffer a significant loss in performance under these conditions. This paper compares the pre…
A radiation-hard quad-channel 12-bit 40 MSPS pipeline analog-to-digital converter (ADC) has been designed for the trigger readout electronics Phase-I upgrade of the ATLAS Liquid Argon calorimeter, at the CERN Large Hadron Collider. The final version of the custom design, fabricated in a commercial 130 nm CMOS process, is presented and found to meet the system requirements for analog performance and radiation tolerance. The procedure for quality control of 17200 ADCs is described and the results are presented.
A Radiation-Hard Dual Channel 4-bit Pipeline for a 12-bit 40 MS/s ADC Prototype with extended Dynamic Range for the ATLAS Liquid Argon Calorimeter Readout Electronics Upgrade at the CERN LHC
The increased particle flux at the high luminosity phase of the Large Hadron Collider (HL-LHC), with instantaneous luminosities of up to 7.5 times the original design value, will have an impact on many sub-systems of the ATLAS detector. This contribution highlights the particular impacts on the ATLAS liquid argon calorimeter system, together with an overview of the various upgrade plans leading up to the HL-LHC. The higher luminosities are of particular importance for the forward calorimeters (FCal), where the expected increase in the ionization load poses a number of problems that can degrade…
An optical link system is being developed for the ATLAS Liquid Argon Calorimeter Phase-II upgrade. The optical link system is responsible for transmit the data of over 182 thousand detector channels from 1524 Front-End Boards (FEBs) through 26 optical fibers per FEB over 150 meters to the counting room and brings clocks, bunch crossing reset signals and slow control/monitoring signals back to the FEBs. The optical link system is based on the Low-Power GigaBit Transceivers (lpGBTs) and the Versatile optical Transceiver (VTRx+) modules, which both are being developed for the High-Luminosity LHC …
The ATLAS experiment at CERN measures energy of proton-proton (p-p) collisions with a repetition frequency of 40 MHz at the Large Hadron Collider (LHC). The readout electronics of liquid-argon (LAr) calorimeters are being prepared for high luminosity-LHC (HL-LHC) operation as part of the phase-II upgrade, anticipating a pileup of up to 200 simultaneous p-p interactions. The increase of the number of p-p interactions implies that calorimeter signals of up to 25 consecutive collisions overlap, making energy reconstruction more challenging. In order to achieve the goal of the HL-HLC, field-progra…
Firmware implementation of a recurrent neural network for the computation of the energy deposited in the liquid argon calorimeter of the ATLAS experiment
Quality control and quality assurance evaluation of ALFE2, a large-dynamic-range front-end ASIC de-veloped for the ATLAS Liquid Argon Calorimeter high-luminosity LHC upgrade
Physics Department, Brookhaven National Laboratory(布鲁克海文国家实验室物理系);Instrumentation Department, Brookhaven National Laboratory(布鲁克海文国家实验室仪器部);Department of Physics and Astronomy, Stony Brook University(石溪大学物理与天文系);IJCLab, Université Paris-Saclay, CNRS/IN2P3(巴黎萨克雷大学IJCLab,CNRS/IN2P3);ESAT-ADVISE, KU Leuven(荷语鲁汶大学ESAT-ADVISE);CERN(欧洲核子研究中心)
Some of the main neutrino oscillation and dark matter experiments have chosen time projection chambers (TPC) filled with liquid argon (LAr) as their technology for the next generation of detectors. Because of its typical drift length of several meters, relatively large cathode voltages are desirable to provide a sizeable drift field. Current designs are based on feedthroughs with high voltages (HV) limited to several hundred kV. The present work proposes a novel method to produce higher voltages inside the detector. It is based on a Van de Graaff HV generator where the charge transporting belt…
Optimised neural networks for online processing of ATLAS calorimeter data on FPGAs
Aix-Marseille Université(艾克斯-马赛大学);Technische Universität Dresden(德累斯顿工业大学);Institut für Kern- und Teilchenphysik, Technische Universität Dresden(德累斯顿工业大学核与粒子物理研究所)
The future proton-proton collider (FCC-hh) will deliver collisions at a center of mass energy up to $\sqrt{s}=100$ TeV at an unprecedented instantaneous luminosity of $L=3~10^{35}$ cm$^{-2}$s$^{-1}$, resulting in extremely challenging radiation and luminosity conditions. By delivering an integrated luminosity of few tens of ab$^{-1}$, the FCC-hh will provide an unrivalled discovery potential for new physics. Requiring high sensitivity for resonant searches at masses up to tens of TeV imposes strong constraints on the design of the calorimeters. Resonant searches in final states containing jets…
The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. Consequently, the background rejection at trigger level is improved through enhanced filtering algorithms utilizing the additional information for topological discrimination of electromagnetic and hadroni…
The LHC upgrade is planned to enhance the instantaneous luminosity during Run 3 from 2021 through 2023. The Phase-I upgrade of the trigger readout electronics for the ATLAS Liquid Argon (LAr) Calorimeters will be installed during the second long shutdown of LHC in 2019-2020. In this upgrade, the so-called super cells are introduced to provide higher granularity, higher resolution and longitudinal shower shape information from the LAr calorimeters to the level-1 trigger processors. A new LAr Trigger Digitizer Board (LTDB) will manipulate and digitize 320 channels of super cell signals, and tran…