The ArDM experiment, a 1 ton liquid argon TPC/Calorimeter, is designed for the detection of dark matter particles which can scatter off the spinless argon nuclei. These events producing a recoiling nucleus will be discerned by their light to charge ratio, as well as the time structure of the scintillation light. The experiment is presently under construction and will be commissioned on surface at CERN. Here we describe the detector concept and give a short review on the main detector components.
The Argon Dark Matter (ArDM) experiment consists of a liquid argon (LAr) time projection chamber (TPC) sensitive to nuclear recoils resulting from scattering of hypothetical Weakly Interacting Massive Particles (WIMPs) on argon targets. With an active target of 850 kg, ArDM represents an important milestone in the quest for Dark Matter with LAr. We present the experimental apparatus currently installed underground at the Laboratorio Subterraneo de Canfranc (LSC), Spain. We show first data recorded during a single-phase commissioning run in 2015 (ArDM Run I), which overall confirm the good and …
We report on a measurement of the attenuation length for the scintillation light in the tonne size liquid argon target of the ArDM dark matter experiment. The data was recorded in the first underground operation of the experiment in single-phase operational mode. The results were achieved by comparing the light yield spectra from 39-Ar and 83m-Kr to a description of the ArDM setup with a model of full light ray tracing. A relatively low value close to 0.5 m was found for the attenuation length of the liquid argon bulk to its own scintillation light. We interpret this result as a presence of op…
ArDM-1t is the first operating ton-scale liquid argon detector for direct search of Dark Matter particles. Developed at CERN as Recognized Experiment RE18, the experiment has been approved in 2010 to be installed in the Spanish underground site LSC (Laboratorio Subterraneo de Canfranc). Under the label of LSC EXP-08-2010 the ArDM detector underwent an intensive period of technical completion and safety approval until the recent filling of the target vessel with almost 2 ton of liquid argon. This report describes the experimental achievements during commissioning of ArDM and the transition into…
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr. After successful operation on surface at CERN, the detector has been deployed underground and is presently commissioned at the Canfranc Underground Laboratory (LSC). In this paper, we describe the status of the installation and present first results on data collected in gas phase.
The ArDM experiment completed a single-phase commissioning run in 2015 with an active liquid argon target of nearly one tonne in mass. The analysis of the data and comparison to simulations allowed for a test of the crucial detector properties and confirmed the low background performance of the setup. The statistical rejection power for electron recoil events using the pulse shape discrimination method was estimated using data from a Cf-252 neutron calibration source. Electron and nuclear recoil band profiles were found to be well described by Gaussian distributions. Employing such a model we …
ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM on the surface at CERN. With a preliminary and incomplete set of PMTs, the light yield at zero electric field is found to be between 0.3-0.5 phe/keVee depending on the position within the detector vol…
Measuring the argon purity is critical for all Ar-based rare event research experiments. Mass spectrometry is typically used to assess the uranium and thorium contamination in samples of the materials used to build low-background detectors; however, this technique has the potential to provide other valuable information that is currently not exploited. We have shown that, by ICP-MS, it is possible to identify and quantify common chemical contaminants in argon. Preliminary tests were done with the gas extracted from the experiments MicroBooNE at FNAL and ArDM at LSC. In the former case, we evide…
The Argon Dark Matter experiment is a ton-scale double phase argon Time Projection Chamber designed for direct Dark Matter searches. It combines the detection of scintillation light together with the ionisation charge in order to discriminate the background (electron recoils) from the WIMP signals (nuclear recoils). After a successful operation on surface at CERN, the detector was recently installed in the underground Laboratorio Subterráneo de Canfranc, and the commissioning phase is ongoing. We describe the status of the installation and present first results from data collected underground …
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, including a 3 l prototype developed to test the charge readout system.
Our group from the University of Zurich is performing R&D work towards the design of a large liquid argon detector to detect Weakly Interacting Massive Particles (WIMPs). This project is developed within the DARWIN Collaboration funded by ASPERA to prepare a proposal for the next generation of WIMP searches using noble liquids. We are performing R&D to detect the VUV light from recoiling argon nuclei. Results obtained with one ton of liquid argon (ArDM prototype) and prospects using a monoenergetic neutron source are discussed.
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr with a charge imaging detector. The ionization charge is extracted from the liquid into the gas phase and there amplified by the use of a Large Electron Multiplier in order to reduce the detection threshold. Direct detection of the ionization charge with fine spatial granularity, combined with a measurement of the amplitude and time evolution of the associated primary scintillat…
The ArDM experiment, a 1 ton liquid argon TPC/Calorimeter, is designed for the detection of dark matter particles which can scatter off the spinless argon nucleus, producing nuclear recoils. These events will be discerned by their light to charge ratio, as well as the time structure of the scintillation light. The experiment is presently under construction and commissioning on surface at CERN. Cryogenic operation and light detection performance was recently confirmed in a test run of the full 1 ton liquid argon target under purely calorimetric operation and with a prototype light readout syste…
Next generation multi-ton scale noble liquid experiments have the unique opportunity to discover dark matter particles at the TeV scale, reaching the sensitivity of 10^-48 cm2 in the WIMP nucleon scattering cross-section. A prerequisite will be the reduction of radiogenic background sources to negligible levels. This is only possible if ultra pure high efficiency photosensors are available for the scintillation light readout. Current experiments (e.g. Xenon, LUX, Darkside, ArDM) use cryogenic PMTs as photosensors. An attractive alternative is represented by silicon photomultiplier arrays (SiPM…
Designs of high-voltage (HV) systems for creating a drift electric field in liquid argon TPCs are reviewed. In ongoing experiments systems capable of approx. 100 kV are realised for a drift field of 0.5-1 kV/cm over a length of up to 1.5 m. Two of them having different approaches are presented: (1) the ICARUS-T600 detector having a system consisting of an external power supply, HV feedthroughs and resistive voltage degraders and (2) the ArDM-1t detector having a cryogenic Greinacher HV multiplier inside the liquid argon volume. For a giant scale liquid argon TPC, a system providing 2 MV may be…
One of the most powerful techniques for direct detection of dark matter via elastic scattering of galactic WIMPs is the use of liquid argon time projection chambers. Atmospheric argon (AAr) has a naturally occurring radioactive isotope, \ar{}, of cosmogenic origin. The use of argon extracted from underground wells, deprived of \ar{}, is key to the physics potential of these experiments. The DarkSide-20k (DS-20k) dark matter search experiment will operate with 50 tonnes of radio-pure underground argon (UAr), extracted from the Urania plant in Cortez (USA) and purified in the Aria distillation p…
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $β$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprive…
DarkSide (DS) at Gran Sasso underground laboratory is a direct dark matter search program based on TPCs with liquid argon from underground sources. The DS-50 TPC, with 50 kg of liquid argon is installed inside active neutron and muon detectors. DS-50 has been taking data since Nov 2013, collecting more than 10^7 events with atmospheric argon. This data represents an exposure to the largest background, beta decays of 39Ar, comparable to the full 3 y run of DS-50 with underground argon. When analysed with a threshold that would give a sensitivity in the full run of about 10^-45 cm2 at a WIMP mas…
In this paper we describe the design, construction, and operation of a first large area double-phase liquid argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the readout consists of a $40\times 76$ cm$^2$ LEM and 2D projective anode to multiply and collect drifting charges. Scintillation light is detected by means of cryogenic PMTs positioned below the cathode. To record both charge and light signals, we have developed a compact acquisition system, which is scalable up to ton-scale detectors with thousands of charge read…
DarkSide-20k (DS-20k) will exploit the physical and chemical properties of liquid argon housed within a large dual-phase time project chamber (TPC) in its direct search for dark matter. The TPC will utilize a compact, integrated design with many novel features to enable the \SI{20}{t} fiducial volume of underground argon. Underground Argon (UAr) is sourced from underground CO$_2$ wells and depleted in the radioactive isotope $^{39}$Ar, greatly enhancing the experimental sensitivity to dark matter interactions. Sourcing and transporting the $\mathcal{O}$(\SI{100}{t}) of UAr for DS-20k is costly…
A brief outline of Dark Matter detection experiments using liquid argon technology is presented. The Pulse Shape background discrimination method (PSD) is described and the example of its use in 2.3 l R&D detector is given. Methods of calculating sensitivity of a Dark Matter detector are discussed and used to estimate the possible improvement of sensitivity after introduction of isotopically depleted liquid argon.
Liquid Argon Time Projection Chambers are planned to comprise a central role in the future of the U.S. High Energy Physics neutrino program. In particular, this detector technology will form the basis for the 40 kton Deep Underground Neutrino Experiment (DUNE). In this paper we take as a starting point the dual phase far detector design proposed by the DUNE experiment and ask what changes are necessary to allow one of the four 10 kt modules to be sensitive to heavy Weakly Interacting Massive Particle (WIMP) dark matter. We show that with control over backgrounds and the use of low radioactivit…
Particle detectors based on liquid argon are now recognised as an attractive technology for dark matter direct detection and coherent elastic neutrino-nucleus scattering measurement. A program using a dual-phase liquid argon detector with a fiducial mass of 200~kg to detect coherent elastic neutrino-nucleus scattering at Taishan Nuclear Power Plant has been proposed. SiPMs will be used as the photon sensor because of their high radio-purity and high photon detection efficiency. S13370-6050CN SiPM, made by Hamamatsu, is a candidate for the detector. In this paper, the characterisation of S13370…
The scintillation yield for recoil Ar ions of 5 to 250 keV energy in liquid argon have been evaluated for direct dark matter searches. Lindhard theory is taken for estimating nuclear quenching. A theoretical model based on a biexcitonic diffusion-reaction mechanism is performed for electronic (scintillation) quenching. The electronic LET (linear energy transfer) is evaluated and used to obtain the initial track structure due to recoil Ar ions. The results are compared with experimental values reported for nuclear recoils from neutrons. The behavior of scintillation and ionization on the field …
Future large liquid argon direct dark matter detectors can benefit greatly from an efficient surface background rejection technique. To aid the development of these large scale detectors a test stand, Argon-1, has been constructed at Carleton University, Ottawa, Canada, in the noble liquid detector development lab. It aims to test a novel surface background rejection technique using a thin layer of slow scintillating material at the surface of the vessel. Through pulse-shape discrimination of the slow light from the scintillating layer, events from the surface of the detector can be discrimina…
DarkSide-50 is the first physics detector of the DarkSide dark matter search program. The detector features a dual-phase underground-argon Time Projection Chamber (TPC) of 50 kg active mass surrounded by an organic liquid-scintillator neutron veto (30 tons) and a water-Cherenkov muon detector (1000 tons). The TPC is currently fully shielded and operating underground at Gran Sasso National Laboratory. A first run of 1422 kg-day exposure with atmospheric argon represents the most sensitive dark matter search using a liquid argon target. The TPC is now filled with underground argon, greatly reduc…
DarkSide is a staged experimental project based on radiopure argon aiming at direct dark matter detection. The DarkSide-50 (DS-50) detector is currently operating underground at the Gran Sasso National Laboratory. DS-50 detector is a dual-phase, 50 kg, liquid argon time-projection-chamber readout by 38 cryogenic PMTs (Hamamatsu R11065), surrounded by an active liquid scintillator veto and contained in a water Cherenkov detector acting as a muon veto. DS-50 has been been operating continuously since 2013, first with atmospheric argon and subsequently filled in 2015 with argon from an undergroun…
One major background in direct searches for weakly interacting massive particles (WIMPs) comes from the deposition of radon progeny on detector surfaces. The most dangerous surface background is the $^{206}$Pb recoils produced by $^{210}$Po decays. In this letter, we report the first characterization of this background in liquid argon. The scintillation signal of low energy Pb recoils is measured to be highly quenched in argon, and we estimate that the 103keV $^{206}$Pb recoil background will produce a signal equal to that of a ~5keV (30keV) electron recoil ($^{40}$Ar recoil). In addition, we …
Enhanced Dark Matter Sensitivity using a Hybrid SiPM-SNSPD-Qubit Detector in Liquid Argon
Laboratory of Advanced Technologies and Instruments, IRSRA(IRSRA先进技术与仪器实验室);Institute of Theoretical Physics, INRC(INRC理论物理研究所);Energy Research Center, Al-Nahrain University(纳海林大学能源研究中心);Laboratory of Quantum Information, JINNR(JINNR量子信息实验室)
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination technique, and the measurement of the residual 39Ar contamination in underground argon, ~3 orders of magnitude lower with respect to atmospheric argon. These results rely on the accurate simulation of the d…
The China Dark Matter Experiment (CDEX) is a low background experiment at China Jinping Underground Laboratory (CJPL) designed to directly detect dark matter with a high-purity Germanium (HPGe) detector. In the second phase CDEX-10 with a 10 kg Germanium array detector system, the liquid argon (LAr) anti-compton active shielding and cooling system is proposed. For purpose of studying the properties of LAr detector, a prototype with an active volume of 7 liters of liquid argon was built and operated. The photoelectron yields, as a critically important parameter for the prototype detector, have …
Possible evidence for the production of Ar$_2^{*-}$ metastable negative molecular ions in gaseous argon of two-phase detectors for dark matter searches
A technique using layered wavelength shifting, scintillating and non-scintillating films is presented to achieve discrimination of surface $α$ events from low-energy nuclear recoils in liquid argon detectors. A discrimination power greater than $10^{8}$, similar to the discrimination possible for electronic recoils in argon, can be achieved by adding a 50 micron layer of scintillator with a suitably slow decay time, approximately 300 ns or greater, to a wavelength-shifter coated surface. The technique would allow suppression of surface $α$ events in a very large next-generation argon dark matt…
The MiniCLEAN dark matter experiment will exploit a single-phase liquid-argon detector instrumented with 92 photomultiplier tubes placed in the cryogen temperature with 4-$π$ coverage of a 500 kg (150 kg) target (fiducial) mass. The detector design strategy emphasizes scalability to target masses of order 10 tons or more. The detector is designed also for a liquid neon target that allows for an independent verification of signal and background and a test of the expected dependence of the WIMP-nucleus interaction rate. For MiniCLEAN, PMT stability and calibration are essential. The \textit{In-s…
In recent years, dark matter direct detection experiments have spurred interest in the Migdal effect, where it is employed to extend their sensitivity to lower dark matter masses. Given the lack of observation of the Migdal effect, the calculation of the signal is subject to large theoretical uncertainties. It is therefore desirable to attempt a first measurement of the Migdal effect, and to test the theoretical predictions of the Migdal effect for the calibration of the experimental response to a potential dark matter signal. In this work, we explore the feasibility of observing the Migdal ef…
Particle detectors based on liquid argon (LAr) have recently become recognized as an extremely attractive technology for the direct detection of dark matter as well as the measurement of coherent elastic neutrino-nucleus scattering (CE$ν$NS). The Chinese argon group at Institute of High Energy Physics has been studying the LAr detector technology and a LAr detector has been operating steadily. A program of using a dual phase LAr detector to measure the CE$ν$NS at Taishang Nuclear Power Plant has been proposed and the R\&D work is ongoing. Considering the requirements of ultra-low radio-purity …
A two-phase argon detector has high discrimination power between electron recoil and nuclear recoil events based on the pulse shape discrimination and the ionization/scintillation ratio (S2/S1). This character is very suitable for the dark matter search to establish the low background experiment. However, the basic properties of S2/S1 of argon are not well known, as compared with xenon. We report the evaluation of S2/S1 properties with a two-phase detector at drift-fields of 0.2-3.0 kV/cm. Finally, the discrimination power against electron recoil background of S2/S1 is discussed.
We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 $\pm$ 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper …
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics includ…
The dynamics of the positive ions created by particle interactions inside argon time projection chambers plays an important role in characterizing the next generation of massive detectors planned for the direct search for dark matter and the study of neutrino properties. We have constructed a 1 L liquid argon chamber (ARION: ARgon ION experiment) with a high voltage pulse generator capable of injecting, in a controlled manner, a sizeable ion current into the drift region. This chamber is capable of reproducing a volume charge similar to that found in large detectors, allowing its effects to be…
Cryogenic performance and long-term stability of Hamamatsu R8520-506 photomultiplier tubes in liquid argon
Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);University of Chinese Academy of Sciences(中国科学院大学);Zhengzhou University(郑州大学)
In the last decade, Direct Dark Matter searches has become a very active research program, spawning dozens of projects world wide and leading to contradictory results. It is on this stage that the Dark matter Experiment with liquid Argon and Pulse shape discrimination (DEAP) is about to enter. With a 3600~kg liquid argon target and a 1000~kg fiducial mass, it is designed to run background free during 3 years, reaching an unprecedented sensitivity of 10$^{-46}$~cm$^2$ for a WIMP mass of 100 GeV. In order to achieve this impressive feat, the collaboration followed a two-pronged approach: a caref…
Proportional electroluminescence (EL) in noble gases is a physical process routinely used in two-phase (liquid-gas) detectors for low-energy astroparticle-physics experiments. In this work, the time properties of visible-light EL in two-phase argon detectors have been systematically studied for the first time. In particular, two unusual slow components in the EL signal, with their contributions and time constants increasing with electric field, were observed. This puzzling property is not expected in any of the known mechanisms of photon and electron emission in two-phase media. Time constants…
A study of the dynamics of the positive charges in liquid argon has been carried out in the context of the future massive time projection chambers proposed for dark matter and neutrino physics. Given their small mobility coefficient in liquid argon, the ions spend a considerably longer time in the active volume with respect to the electrons. The positive charge density can be additionally increased by the injection, in the liquid volume, of the ions produced by the electron multiplying devices located in gas argon. The impact of the ion current on the uniformity of the field has been evaluated…
Decays of radioisotopes on inner detector surfaces can pose a major background concern for the direct detection of dark matter. While these backgrounds are conventionally mitigated with position cuts, these cuts reduce the exposure of the detector by decreasing the sensitive mass, and uncertainty in position determination may make it impossible to adequately remove such events in certain detectors. In this paper, we provide a new technique for substantially reducing these surface backgrounds in liquid argon (LAr) detectors, independent of position cuts. These detectors typically use a coating …
The China Dark Matter Experiment (CDEX) Collaboration will carry out a direct search for weakly interacting massive particles with germanium detectors. Liquid argon will be utilized as an anti-Compton and cooling material for the germanium detectors. A low-background and large-area photomultiplier tube (PMT) immersed in liquid argon will be used to read out the light signal from the argon. In this paper we carry out a careful evaluation on the performance of the PMT operating at both room and cryogenic temperatures. Based on the single photoelectron response model, the absolute gain and resolu…
Gas Electroluminescence in a Dual Phase Xenon-Doped Argon Detector
Lawrence Livermore National Laboratory(劳伦斯利弗莫尔国家实验室);University of California Davis(加州大学戴维斯分校);University of California San Diego(加州大学圣地亚哥分校);University of California Riverside(加州大学河滨分校)
We examine the sensitivity of a large scale two-phase liquid argon detector to the directionality of the dark matter signal. This study was performed under the assumption that, above 50 keV of recoil energy, one can determine (with some resolution) the direction of the recoil nucleus without head-tail discrimination, as suggested by past studies that proposed to exploit the dependence of columnar recombination on the angle between the recoil nucleus direction and the electric field. In this paper we study the differential interaction recoil rate as a function of the recoil direction angle with…
The propagation velocity of scintillation light in liquid argon $v_{g}$ at $λ\sim 128$~nm wavelength, has been measured for the first time in a dedicated experimental setup at CERN.\\ The obtained result $\frac{1}{v_{g}} = 7.46 \pm 0.08$~ns/m , is then used to derive the value of the refractive index (n) and the Rayleigh scattering length ($\mathcal{L}$) for liquid argon in the VUV region. For $λ= 128$~nm we found $n= 1.358 \pm 0.003$ and $\mathcal{L}= 99.1 \pm 2.3$~cm. The measured values are of interest for a variety of experiments searching for rare events like neutrino and dark matter inte…
Liquid argon-based scintillation detectors are important for dark matter searches and neutrino physics. Argon scintillation light is in the vacuum ultraviolet region, making it hard to be detected by conventional means. Polyethylene naphthalate (PEN), an optically transparent thermoplastic polyester commercially available as large area sheets or rolls, is proposed as an alternative wavelength shifter to the commonly-used tetraphenyl butadiene (TPB). By combining the existing literature data and spectrometer measurements relative to TPB, we conclude that the fluorescence yield and timing of bot…
At present, a two-phase argon detector is being developed in our laboratory for dark matter search and low-energy neutrino experiments. To calibrate its energy scale a $^{109}$Cd gamma-ray source was used. In this work a detailed emission spectrum of the $^{109}$Cd source was measured using YAP:Ce scintillator and high-purity germanium (HPGe) detectors. It is shown that the $^{109}$Cd source, equipped with a W substrate and a Cu filter, can provide a complete set of gamma-ray lines, ranging from 8 to 90 keV, for the energy calibration of two-phase detectors. These measurements allowed us to su…