ArDM氩暗物质探测器波长移动涂层反射器的研制

Development of wavelength shifter coated reflectors for the ArDM argon dark matter detector

The ArDM Collaboration, V. Boccone, P. K. Lightfoot, K. Mavrokoridis, C. Regenfus, C. Amsler, A. Badertscher, A. Bueno, H. Cabrera, M. C. Carmona-Benitez, M. Da… 展开作者

The ArDM Collaboration, V. Boccone, P. K. Lightfoot, K. Mavrokoridis, C. Regenfus, C. Amsler, A. Badertscher, A. Bueno, H. Cabrera, M. C. Carmona-Benitez, M. Daniel, E. J. Daw, U. Degunda, A. Dell'Antone, A. Gendotti, L. Epprecht, S. Horikawa, L. Kaufmann, L. Knecht, M. Laffranchi, C. Lazzaro, D. Lussi, J. Lozano, A. Marchionni, A. Melgarejo, P. Mijakowski, G. Natterer, S. Navas-Concha, P. Otyugova, M. de Prado, P. Przewlocki, F. Resnati, M. Robinson, J. Rochet, L. Romero, E. Rondio, A. Rubbia, N. J. C. Spooner, T. Strauss, J. Ulbricht, T. Viant

摘要:

为了优化ArDM 1吨液氩暗物质探测器中光读出的设计,在几个小的设置中研究了一系列反射器和WLS涂层组合,其中氩闪烁光由气体中的放射源在常温常压下产生,并通过四苯基丁二烯(TPB)转移到蓝色区域。通过喷涂和真空蒸发将各种厚度的TPB沉积到镜面3 M { \small \texttrademark }-箔和漫射Tetratex{ \small \textregistered }(TTX)基底上。比较每个反射器和TPB涂层组合的光输出。使用分光辐射计在200和650 nm之间的波长范围内独立地测量TPB涂覆的反射器的反射系数。还研究了PMT窗口上的WLS涂层。这些测量被用来定义ArDM实验的光反射器的参数。将15个大的$120\times 25$ cm $^2$ TTX片材涂覆并组装在检测器中。氩气中的测量报告提供了很好的证据,满足光收集的实验要求。

英文摘要:

To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were deposited by spraying and vacuum evaporation onto specular 3M{\small\texttrademark}-foil and diffuse Tetratex{\small\textregistered} (TTX) substrates. Light yields of each reflector and TPB coating combination were compared. Reflection coefficients of TPB coated reflectors were independently measured using a spectroradiometer in a wavelength range between 200 and 650 nm. WLS coating on the PMT window was also studied. These measurements were used to define the parameters of the light reflectors of the ArDM experiment. Fifteen large $120\times 25$ cm$^2$ TTX sheets were coated and assembled in the detector. Measurements in argon gas are reported providing good evidence of fulfilling the light collection requirements of the experiment.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑