arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2009.06148physics.ins-det
收藏

用于ATLAS液氩量热计读数升级的两个低功耗光学数据传输ASIC

Two low-power optical data transmission ASICs for the ATLAS Liquid Argon Calorimeter readout upgrade

Le Xiao, Wei Zhou, Quan Sun, Binwei Deng, Datao Gong, Di Guo, Huiqin He, Suen Hou, Chonghan Liu, Tiankuan Liu, James Thomas, Jian Wang, Annie C. Xiang, Dongxu Y… 展开作者

Le Xiao, Wei Zhou, Quan Sun, Binwei Deng, Datao Gong, Di Guo, Huiqin He, Suen Hou, Chonghan Liu, Tiankuan Liu, James Thomas, Jian Wang, Annie C. Xiang, Dongxu Yang, Jingbo Ye, Xiandong Zhao

摘要:

ATLAS液氩量热计第一阶段升级中,前端光学数据传输需要串行化ASIC和VCSEL驱动ASIC。基准ASIC是串行器LOCx 2和VCSEL驱动器LOCld,采用0.25 μm硅蓝宝石(SoS)CMOS技术设计,功耗分别为843 mW和320 mW。基于130 nm CMOS工艺,我们设计了两个引脚到引脚兼容的备份ASIC,LOCx 2 -130和LOCld-130。它们的功耗比同类产品低得多,而其他性能,如延迟,数据速率和辐射耐受性,满足第一阶段升级的要求。我们提出了LOCx 2 -130和LOCld-130的设计。最后给出了LOCx 2 -130的测试结果。

英文摘要:

A serializer ASIC and a VCSEL driver ASIC are needed for the front-end optical data transmission in the ATLAS liquid argon calorimeter readout phase-I upgrade. The baseline ASICs are the serializer LOCx2 and the VCSEL driver LOCld, designed in a 0.25-μm Silicon-on-Sapphire (SoS) CMOS technology and consumed 843 mW and 320 mW, respectively. Based on a 130-nm CMOS technology, we design two pin-to-pin-compatible backup ASICs, LOCx2-130 and LOCld-130. Their power consumptions are much lower then of their counterparts, whereas other performance, such as the latency, data rate, and radiation tolerance, meet the phase-I upgrade requirements. We present the design of LOCx2-130 and LOCld-130. The test results of LOCx2-130 are also presented.