Calice Si-W EM量热仪:2006年测试梁的初步结果

Calice Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006

C. Carloganu, A. -M. Magnan

摘要:

CALICE Si-W电磁量能器于2006年5月在DESY进行了电子束(1至6 GeV)测试,并于2006年8月和10月在CERN进行了电子(6至45 GeV)和强子(6至80 GeV)测试。在不同的入射角和三个光束撞击位置拍摄了数百万个事件。ECAL校准与μ子束进行,并显示出良好的均匀性,几乎所有的通道。可用的大量统计数据不仅可以验证ECAL的物理性能,还可以识别细微的硬件影响。

英文摘要:

The CALICE Si-W electromagnetic calorimeter has been tested with electron beams (1 to 6 GeV) at DESY in May 2006, as well as electrons (6 to 45 GeV) and hadrons (6 to 80 GeV) at CERN in August and October 2006. Several millions of events have been taken at different incident angles and three beam impact positions. The ECAL calibration is performed with muon beams and shows a good uniformity for nearly all channels. The large statistics available allows not only to characterise the ECAL physics performance, but also to identify subtle hardware effects.