用于精密测量的亚阿托法拉电容传感器噪声与热性能及其在引力波探测器中的应用

Noise and Thermal Performance of a Sub-Attofarad Capacitance Sensor for Precision Measurements, with Applications in Gravitational Wave Detectors

S. Saraf, S. Buchman, C. Y. Lui, S. Wang, J. Lipa

AI总结:

本文介绍了一种基于无间隙MnZn铁氧体磁芯的交流谐振电容桥传感器,在293K和120K下分别达到0.225和0.118 aF/√Hz的灵敏度,优于同类电容桥,适用于空间引力波探测。

摘要:

我们描述了一种精密交流谐振电容桥(RCB)传感器的设计原理、制造和表征。该传感器基于带有实心(无间隙)MnZn铁氧体磁芯的谐振差分平面印刷电路板变压器,在293 K温度下,约120 kHz谐振频率和1 Hz傅里叶测量频率下,短期灵敏度为0.225 ± 0.005 aF/√Hz。在120 K时,RCB的短期噪声灵敏度为0.118 ± 0.005 aF/√Hz。我们将无间隙配置与五种不同的RCB进行了比较;其中三种磁芯间隙为65微米,两种磁芯间隙为130微米。它们在室温下的平均短期噪声灵敏度分别为0.30 ± 0.01 aF/√Hz和0.45 ± 0.01 aF/√Hz,而在120 K低温下运行这些变压器时,平均灵敏度分别为0.23 ± 0.01 aF/√Hz和0.36 ± 0.01 aF/√Hz。对三种间隙类型各一个磁芯进行了多小时的室温运行,证明了其长期灵敏度的稳定性:无间隙(40小时持续时间)为0.234 ± 0.005 aF/√Hz,65微米和130微米间隙(28小时持续时间)分别为0.338 ± 0.009 aF/√Hz和0.435 ± 0.010 aF/√Hz。在0.1 mHz(空间引力波探测器的关键频率)下,相应的灵敏度分别为0.25 ± 0.02 aF/√Hz、0.35 ± 0.02 aF/√Hz和0.53 ± 0.07 aF/√Hz。使用无间隙变压器配置在325 K至349 K温度范围内的测量进一步验证了噪声模型对温度和磁导率的依赖性。我们的无间隙磁芯RCB的性能与计算性能值相匹配,并且与为类似应用开发的电容桥相比,信噪比提高了两倍或更多。通过冷却至120 K,噪声进一步降低了约两倍。

英文摘要:

We describe the design principles, fabrication, and characterization of a precision AC resonant capacitance bridge (RCB) sensor, based on a resonant differential planar printed circuit board transformer with a solid (ungapped) MnZn ferrite core, demonstrating a short-term sensitivity at 293 K of 0.225 +/- 0.005 aF/rtHz, at around 120 kHz resonance frequency and 1 Hz Fourier measurement frequency. At 120 K the RCB short term noise sensitivity is 0.118 +/- 0.005 aF/rtHz. We compare the ungapped configuration to five different RCBs; three with a core gap of 65 um and two with a core gap of 130 um. Their average room temperature short term noise sensitivities are 0.30 +/- 0.01 aF/rtHz and 0.45 +/- 0.01 aF/rtHz, while the cryogenic operation of these transformers at 120 K resulted in averaged sensitivities of 0.23 +/- 0.01 aF/rtHz and of 0.36 +/- 0.01 aF/rtHz respectively. Multi-hour room temperature runs, with one core of each of the three gap types, proved the stability of their long-term sensitivities of 0.234 +/- 0.005 aF/rtHz, 0.338 +/- 0.009 aF/rtHz, and 0.435 +/- 0.010 aF/rtHz for the ungapped (40-hour duration) and the 65 um and 130 um (28-hour duration) cores respectively. At 0.1 mHz, a critical frequency for space gravitational wave detectors, the respective sensitivities are 0.25 +/- 0.02 aF/rtHz, 0.35 +/- 0.02 aF/rtHz, and 0.53 +/- 0.07 aF/rtHz. Measurements with the ungapped transformer configuration for temperatures from 325 K to 349 K further validate the dependence of the noise model on the temperature and permeability. The performance of our RCB with an ungapped core matches the calculated performance value and shows an improvement in signal-to-noise of two or more compared with capacitance bridges developed for similar applications. A further factor of about two noise reduction is achieved by cooling to 120 K.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑