Silicon microstrip detectors are widely used in experiments for space astronomy. Before the detector is assembled, extensive characterization of the silicon microstrip sensors is indispensable and challenging. This work electrically evaluates a series of sensor parameters, including the depletion voltage, bias resistance, metal strip resistance, total leakage current, strip leakage current, coupling capacitance, and interstrip capacitance. Two methods are used to accurately measure the strip leakage current, and the test results match each other well. In measuring the coupling capacitance, we extract the correct value based on a SPICE model and two-port network analysis. In addition, the expression of the measured bias resistance is deduced based on the SPICE model.
The DArk Matter Particle Explorer (DAMPE) is one of the four satellites within the Strategic Pioneer Research Program in Space Science of the Chinese Academy of Science (CAS). The Silicon-Tungsten Tracker (STK), which is composed of 768 singled-sided silicon microstrip detectors, is one of the four subdetectors in DAMPE, providing track reconstruction and charge identification for relativistic charged particles. The charge response of DAMPE silicon microstrip detectors is complicated, depending on the incident angle and impact position. A new charge reconstruction algorithm for the DAMPE silic…
We report recent results on the use of charge division to obtain a longitudinal coordinate from silicon strip detectors, and on sources of electronic readout noise for long, thin strips. These results hold promise for the design of Linear Collider charged particle tracking system composed of silicon microstrip sensors.
The D0 Run II silicon microstrip tracker (SMT) has 3 square meters of Si area. There are 792,576 channels read out by 6192 SVXIIe chips on 912 read out modules. The SMT provides track and vertex reconstruction capabilities over the full pseudorapidity coverage of the D0 detector. The full detector has been running successfully since April 2002. This presentation covers the experience in commissioning and operating, the recent electronics upgrade which improved stability of the SMT and estimates of the radiation damage.
A flexible apparatus for calibration of the absolute flux at the focal plane of the X-ray Source of a Powder Diffractometer, based on a fast scintillator counter, is presented. The measured fluxes, depending on the high voltage on the X-ray tube, were at the range 200 - 400 MHz, while an uncertainty in the flux of the order of 5% has been estimated. We also applied this calibration for radiation hardness study of a multichannel silicon microstrip X-Ray detector.
We summarize the R&D activities on a novel semitransparent microstrip sensor to be used on laser-based alignment systems for silicon trackers. The new sensor is used both for particle tracking and laser detection. The aim of this research line is to increase the optical transmittance (T) of Silicon microstrips detectors to infrared light, introducing minor modifications to the sensor design still suitable for its industrial production. The optical simulations used in the sensor design have been experimentally validated against several patterned material samples. This activities have been carri…
This paper reports the design, fabrication and characterization of single-sided silicon microstrip sensors with integrated biasing resistors and coupling capacitors, produced for the first time in India. We have first developed a prototype sensor on a four-inch wafer. After finding suitable test procedures for characterizing these AC coupled sensors, we have fine-tuned various process parameters in order to produce sensors with the desired specifications.
New method for clustering thresholds determination in Microstrip Silicon Detector
University of Torino(都灵大学);University of Pisa(比萨大学);University of Napoli(那不勒斯大学);University of Rome La Sapienza(罗马第一大学);University of Foggia(福贾大学);University of Bologna(博洛尼亚大学);CNAO National Center for Oncological Hadrontherapy(CNAO国家肿瘤重离子治疗中心);GSI Helmholtzzentrum für Schwerionenforschung(德国重离子研究中心);Université de Strasbourg(斯特拉斯堡大学);University of Bari(巴里大学);University of Perugia(佩鲁贾大学);University of Miami(迈阿密大学);Trento Institute for Fundamental Physics and Applications, INFN(特伦托基础物理与应用研究所,意大利国家核物理研究所);University of Rome Tor Vergata(罗马第二大学);University of Piemonte Orientale(皮埃蒙特东方大学);INFN Laboratori Nazionali di Frascati(意大利国家核物理研究所弗拉斯卡蒂国家实验室);Nagoya University(名古屋大学);University of Trento(特伦托大学);University of Camerino(卡梅里诺大学);Technische Universität Darmstadt(达姆施塔特工业大学);University of Applied Sciences, Giessen(吉森应用科学大学);INFN, Gran Sasso National Laboratories(意大利国家核物理研究所格兰萨索国家实验室)
In next ten years, the Large Hadron Collider will be upgraded to the High Luminosity LHC (HL-LHC), resulting in ten time more integrated luminosity. To withstand the much harsher radiation and occupancy conditions of the HL-LHC, the inner tracker of the ATLAS detector must be redesigned and rebuilt completely. The design of the ATLAS Upgrade inner tracker (ITk) has already been defined. It consists of several layers of silicon particle detectors. The innermost layers will be composed of silicon pixel sensors, and the outer layers will consist of silicon microstrip sensors. This paper will focu…
The Semiconductor Tracker (SCT) is a silicon strip detector and one of the key precision tracking devices in the Inner Detector of the ATLAS experiment at CERN LHC. The completed SCT has been installed inside the ATLAS experimental cavern since 2007 and has been operational since then. Calibration data has been taken regularly and analyzed to determine the performance of the system. In this paper the current status of the SCT is reviewed, including results from data-taking periods in 2010 and 2011. We report on the operation of the detector including overviews on services, connectivity and obs…
A PC based high speed silicon microstrip beam telescope consisting of several independent modules is presented. Every module contains an AC-coupled double sided silicon microstrip sensor and a complete set of analog and digital signal processing electronics. A digital bus connects the modules with the DAQ PC. A trigger logic unit coordinates the operation of all modules of the telescope. The system architecture allows easy integration of any kind of device under test into the data acquisition chain. Signal digitization, pedestal correction, hit detection and zero suppression are done by hardwa…
The XAA1.2 is a custom ASIC chip for silicon microstrip detectors adapted by Ideas for the SuperAGILE instrument on board the AGILE space mission. The chip is equipped with 128 input channels, each one containing a charge preamplifier, shaper, peak detector and stretcher. The most important features of the ASIC are the extended linearity, low noise and low power consumption. The XAA1.2 underwent extensive laboratory testing in order to study its commandability and functionality and evaluate its scientific performances. In this paper we describe the XAA1.2 features, report the laboratory measur…
Gotthard-II is a 1-D microstrip detector specifically developed for the European X-ray Free-Electron Laser. It will not only be used in energy dispersive experiments but also as a beam diagnostic tool with additional logic to generate veto signals for the other 2-D detectors. Gotthard-II makes use of a silicon microstrip sensor with a pitch of either 50 μm or 25 μm and with 1280 or 2560 channels wire-bonded to adaptive gain switching readout chips. Built-in analog-to-digital converters and digital memories will be implemented in the readout chip for a continuous conversion and storage of frame…
In the context of the Silicon tracking for a Linear Collider (SiLC) R&D collaboration, a highly compact mixed-signal chip has been designed in 130nm CMOS technology intended to read Silicon strip detectors for the experiments at the future International Linear Collider. The chip includes eighty eight channels of a full analog signal processing chain and analog to digital conversion with the corresponding digital controls and readout channels. The chip is 5x10mm2 where the analog implementation represents 4/5 of the total Silicon area.
The algorithms for position reconstruction in silicon micro-strip detectors are studied, and the signals of a minimum ionizing particle are simulated. The center-of-gravity distributions of the data events allow the fine tuning of the signal forms and of the strip response functions. In the sensors with floating strips the response function turns out to roughly approximate the response of a triangular function for the size of the signal involved. The simulations are extended to non orthogonal incidence. In these directions, and in general for all the asymmetric signal distributions, the standa…
Beam Test Characterization of Silicon Microstrip Detector Flight-Model Ladders for the AMS-02 Upgrade
Institute of High Energy Physics(高能物理研究所);University of Chinese Academy of Sciences(中国科学院大学);INFN Sezione di Perugia(佩鲁贾国家核物理研究所分部);Massachusetts Institute of Technology (MIT)(麻省理工学院);Institute of Physics, Academia Sinica(台湾中央研究院物理研究所)
An experimental set up, dedicated to isolate an error present in the $η$-algorithm, gave an unexpected result. The average of a center of gravity algorithm at orthogonal particle incidence turns out to be non zero. This non zero average signals an asymmetry in the response function of the strips, and introduces a further parameter in the corrections: the shift of the strip response center of gravity respect its geometrical position. A strategy to extract this parameter from a standard data set is discussed. Some simulations with various asymmetric response functions are explored for this test.…
We present a design for an array of kinetic inductance detectors (KIDs) integrated with phased array antennas for imaging at 150 GHz under high background conditions. The microstrip geometry KID detectors are projected to achieve photon noise limited sensitivity with larger than 100 pW absorbed optical power. Both the microstrip KIDs and the antenna feed network make use of a low-loss amorphous silicon dielectric. A new aspect of the antenna implementation is the use of a NbTiN microstrip feed network to facilitate impedance matching to the 50 Ohm antenna. The array has 256 pixels on a 6-inch …
We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.
Within CERN RD50 Collaboration, MCz Si was identified as a best material for the detector used in the high luminosity collider experiments. The n in p Si detectors were utmost radiation hard detectors, which can be used for the phase 2 upgrade plan of the new Compact Muon Solenoid tracker detector in 2026. The choice of n or p-MCz Si material depends upon the high electrical charge collection efficiency performance of these detectors over n or p-FZSi detectors. The bulk radiation damage model for n, p-MCz Si need to develop for the designing, development and optimization of the advanced detect…
We discuss results on the use of charge division to estimate the longitudinal position of charge deposition in silicon microstrip sensors, and on the intrinsic noise limitation of microstrip sensors in the limit of long, narrow strips. We find a resolution of \pm6% of the length of the sensor for a 10cm-long sensor. We also find that network effects significantly reduce sensor readout noise relative to naive expectations that arise from treating the detector resistance and capacitance as single discrete electronic components.
A lot of R & D work is carried out in the CERN RD50 Collaboration to find out the best material for the Si detectors that can be used in the harsh radiation environment of HL-LHC, n and p-MCz Si was identified as one of the prime candidates as a material for strip detector that can be chosen the phase 2 upgrade plan of the new Compact Muon Solenoid tracker detector in 2026. For the very first time, in this work, an advanced four level deep-trap mixed irradiation model for p-MCz Si is proposed by the comparison of experimental data on the full depletion voltage and leakage current to the Shockl…
While the tracking detectors of the ATLAS and CMS experiments have shown excellent performance in Run 1 of LHC data taking, and are expected to continue to do so during LHC operation at design luminosity, both experiments will have to exchange their tracking systems when the LHC is upgraded to the high-luminosity LHC (HL-LHC) around the year 2024. The new tracking systems need to operate in an environment in which both the hit densities and the radiation damage will be about an order of magnitude higher than today. In addition, the new trackers need to contribute to the first level trigger in …
We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell $^{\circledR}$ lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.
This paper describes the mechanical design, the readout chain, the production, testing and the installation of the Silicon Microstrip Tracker of the D0 experiment at the Fermilab Tevatron collider. In addition, description of the performance of the detector during the experiment data collection between 2001 and 2010 is provided.
The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential through a sizable increase in the luminosity up to 6*10^34 cm^-2 s^-1. A consequence of this increased luminosity is the expected radiation damage at 3000 fb^-1 after ten years of operation, requiring the tracking detectors to withstand fluences to over 1*10^16 1 MeV n_eq/cm^2 . In order to cope with the consequent increased readout rates, a complete re-design of the current ATLAS Inner Detector (ID) is being developed as the Inner Tracker (ITk). Two proposed detectors for the ATLAS strip track…
In September 2008 the Slim5 collaboration submitted a low material budget silicon demonstrator to test with 12 GeV/c protons, at the PS-T9 test-beam at CERN. Inside the reference telescope, two different detectors were placed as device under test (DUT). The first was a 4k-Pixel Matrix of Deep N Well MAPS, developed in a 130 nm CMOS Technology, providing digital sparsified readout. The other one was a high resistivity double sided silicon detector, with short strips at 45-degree angle to the detector's edge, read out by the FSSR2 chip. The FSSR2 is a 128 channel data-driven fast readout chip de…
We report on progress in the development of the LSTFE2 prototype front-end ASIC geared towards the readout of silicon microstrip sensors in a Linear Collider detector. We also discuss progress in the design of the back-end digital architecture for this readout scheme.
Among the top priorities for high-energy astronomy in the coming decade are sensitive surveys in the hard X-ray/soft γ-ray (10-600 keV) and medium-energy γ-ray (0.2-80 MeV) bands. Historically, observations in the soft and medium energy γ-ray bands have been conducted using detectors based on inorganic scintillators read out by photo-multiplier tubes (PMTs). These observations were limited by the modest energy and time resolution of traditional scintillator materials (e.g. NaI and CsI), and by the demands on mission resources imposed by the bulky, fragile, high-voltage PMTs. Recent technologic…
Large-area silicon photomultipliers (SiPMs) are desired in many applications where large surfaces have to be covered. For instance, a large area SiPM has been developed by Hamamatsu Photonics in collaboration with the University of Geneva, to equip gamma-ray cameras employed in imaging atmospheric Cherenkov telescopes. Being the sensor about 1 cm$^2$, a suitable preamplification electronics has been investigated in this work, which can deal with long pulses induced by the large capacitance of the sensor. The so-called Multiple Use SiPM Integrated Circuit (MUSIC), developed by the ICCUB (Univer…
We have examined the effects of embedded pitch adapters on signal formation in n-substrate silicon microstrip sensors with data from beam tests and simulation. According to simulation, the presence of the pitch adapter metal layer changes the electric field inside the sensor, resulting in slowed signal formation on the nearby strips and a pick-up effect on the pitch adapter. This can result in an inefficiency to detect particles passing through the pitch adapter region. All these effects have been observed in the beam test data.
University of Tübingen(图宾根大学);GSI Helmholtzzentrum für Schwerionenforschung GmbH(亥姆霍兹重离子研究中心有限责任公司)
We describe a setup for optical quality assurance of silicon microstrip sensors. Pattern recognition algorithms were developed to analyze microscopic scans of the sensors for defects. It is shown that the software has a recognition and classification rate of $>$~90\% for defects like scratches, shorts, broken metal lines etc. We have demonstrated that advanced image processing based on neural network techniques is able to further improve the recognition and defect classification rate.
The single-mirror small-size telescope (SST-1M) is one of the three proposed designs for the small-size telescopes (SSTs) of the Cherenkov Telescope Array (CTA) project. The SST-1M will be equipped with a 4 m-diameter segmented mirror dish and an innovative fully digital camera based on silicon photo-multipliers (SiPMs). Since the SST sub-array will consist of up to 70 telescopes, the challenge is not only to build a telescope with excellent performance, but also to design it so that its components can be commissioned, assembled and tested by industry. In this paper we review the basic steps t…
This paper presents a first study of the performance of a novel 2D position-sensitive microstrip detector, where the resistive charge division method was implemented by replacing the metallic electrodes with resistive electrodes made of polycrystalline silicon. A characterization of two proof-of-concept prototypes with different values of the electrode resistivity was carried out using a pulsed Near Infra-Red laser. The experimental data were compared with the electrical simulation of the sensor equivalent circuit coupled to simple electronics readout circuits. The good agreement between exper…
This paper reports on the design optimization done for Double Sided silicon microStrip Detectors(DSSDs) to reduce the Equivalent Noise Charge (ENC) and to maximize the breakdown voltage and Charge Collection Efficiency. Various isolation techniques have been explored and a detailed comparison has been studied to optimize the detector performance. For the evaluation of the performance of the silicon detectors, a radiation damage model has been included. The neutron fluence is expected to be 2x10^{13}n_{eq} cm$^{-2}$ per year for five years of expected CBM run with intermediate periods of warm m…
The Belle II experiment at the SuperKEKB collider in Japan is designed to indirectly probe new physics using approximately 50 times the data recorded by its predecessor. An accurate determination of the decay-point position of subatomic particles such as beauty and charm hadrons as well as a precise measurement of low-momentum charged particles will play a key role in this pursuit. These will be accomplished by an inner tracking device comprising two layers of pixelated silicon detector and four layers of silicon vertex detector based on double-sided microstrip sensors. We describe herein the …
The alignment procedure of the Silicon Microstrip Tracker, SMT, and the Central Fiber Tracker, CFT, is described. Alignment uncertainties and resulting systematic errors in physics analyses are addressed.
ATLAS experiment, designed to probe the interactions of particles emerging out of proton proton collisions at energies of up to 14 TeV, will assume operation at the Large Hadron Collider (LHC) at CERN in 2007. This paper discusses the assembly and the quality control tests of forward detector modules for the ATLAS silicon microstrip detector assembled at the Instituto de Fisica Corpuscular (IFIC) in Valencia. The construction and testing procedures are outlined and the laboratory equipment is briefly described. Emphasis is given on the module quality achieved in terms of mechanical and electri…
The Belle II experiment, which is situated at the interaction point of the SuperKEKB $e^+e^{-}$ collider at KEK, Tsukuba, Japan, is expected to collect data corresponding to an integrated luminosity of 50~ab$^{- 1}$. This data set will be sensitive to beyond-the-standard-model physics via precision measurements and searches for very rare decays. At its heart lies a six-layer vertex detector consisting of two layers of pixel detectors (PXD) and four layers of double-sided silicon microstrip detectors (SVD). Precise vertexing as provided by this device is essential for measurements of time-depen…
We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800-1400 nm band. Previous large optical and near-IR MKID arrays were fabricated using substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays, however, suffered from severe non-uniformities in the TiN critical temperat…
Gotthard-II is a silicon microstrip detector developed for the European X-ray Free-Electron Laser (XFEL.EU). Its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), energy dispersive experiments at 4.5 MHz frame rate, beam diagnostics, as well as veto signal generation for pixel detectors. Gotthard-II uses a silicon microstrip sensor with a pitch of 50 $μ$m or 25 $μ$m and with 1280 or 2560 channels wire-bonded to readout chips (ROCs). In the ROC, an adaptive gain switching pre-amplifier (PRE), a fully di…
As the start up date for LHC approaches, the detectors are readying for data taking. Here a review will be given on the construction phase with insights into the various difficulties encountered during the process. An overview will also be given of the commissioning strategy and results obtained so far. The CMS tracker is the largest silicon microstrip detector ever built. Consisting of three main subsystems, Inner Barrel and Disks, Outer Barrel and End Caps, it is 5.4m long and is 2.4m in diameter. Total detector surface is an unprecedented 200m^2 with more than 15000 detector modules. The va…
We have investigated the depletion voltage changes, the leakage current increase and the charge collection efficiency of a silicon microstrip detector identical to those used in the inner layers of the BaBar Silicon Vertex Tracker (SVT) after heavy non-uniform irradiation. A full SVT module with the front-end electronics connected has been irradiated with a 0.9 GeV electron beam up to a peak fluence of 3.5 x 10^14 e^-/cm^2, well beyond the level causing substrate type inversion. We irradiated one of the two sensors composing the module with a non-uniform profile with sigma=1.4 mm that simulate…
The First G-APD Cherenkov telescope (FACT) is the first telescope using silicon photon detectors (G-APD aka. SiPM). The use of Silicon devices promise a higher photon detection efficiency, more robustness and higher precision than photo-multiplier tubes. Since the properties of G-APDs depend on auxiliary parameters like temperature, a feedback system adapting the applied voltage accordingly is mandatory. In this presentation, the feedback system, developed and in operation for FACT, is presented. Using the extraction of a single photon-equivalent (pe) spectrum as a reference, it can be proven …
LHCb is a forward spectrometer experiment dedicated to the study of new physics in the decays of beauty and charm hadrons produced in proton collisions at the Large Hadron Collider (LHC) at CERN. The VErtex LOcator (VELO) is the microstrip silicon detector surrounding the interaction point, providing tracking and vertexing measurements. The upgrade of the LHCb experiment, planned for 2018, will increase the luminosity up to $\rm 2\times10^{33}\ cm^{-2}s^{-1}$ and will perform the readout as a trigger-less system with an event rate of 40 MHz. Extremely non-uniform radiation doses will reach up …
Low-noise, position-sensitive Silicon Drift Detectors (SDDs) are particularly useful for experiments in which a good energy resolution combined with a large sensitive area is required, as in the case of X-ray astronomy space missions and medical applications. This paper presents the experimental characterization of VEGA, a custom Application Specific Integrated Circuit (ASIC) used as the front-end electronics for XDXL-2, a large-area (30.5 cm^2) SDD prototype. The ASICs were integrated on a specifically developed PCB hosting also the detector. Results on the ASIC noise performances, both stand…
Segmented silicon detectors (micropixel and microstrip) are the main type of detectors used in the inner trackers of Large Hadron Collider (LHC) experiments at CERN. Due to the high luminosity and eventual high fluence, detectors with fast response to fit the short shaping time of 20 ns and sufficient radiation hardness are required. Measurements carried out at the Ioffe Institute have shown a reversal of the pulse polarity in the detector response to short-range charge injection. Since the measured negative signal is about 30-60% of the peak positive signal, the effect strongly reduces the CC…
We have carried out a detailed programme to explore the superconducting characteristics of reactive DC-magnetron sputtered NbN. The basic principle is to ignite a plasma using argon, and then to introduce a small additional nitrogen flow to achieve the nitridation of a Nb target. Subsequent sputtering leads to the deposition of NbN onto the host substrate. The characteristics of a sputtered film depend on a number of parameters: argon pressure, nitrogen flow rate and time-evolution profile, substrate material, etc. Crucially, the hysteresis in the target voltage as a function of the nitrogen f…
We have been developing monolithic active pixel sensors for X-rays based on the silicon-on-insulator technology. Our device consists of a low-resistivity Si layer for readout CMOS electronics, a high-resistivity Si sensor layer, and a SiO$_2$ layer between them. This configuration allows us both high-speed readout circuits and a thick (on the order of $100~μ{\rm m}$) depletion layer in a monolithic device. Each pixel circuit contains a trigger output function, with which we can achieve a time resolution of $\lesssim 10~μ{\rm s}$. One of our key development items is improvement of the energy re…
We have carried out a detailed programme to explore the superconducting characteristics of reactive DC-magnetron sputtered NbN. The basic principle is to ignite a plasma using argon, and then to introduce a small additional nitrogen flow to achieve the nitridation of a Nb target. Subsequent sputtering leads to the deposition of NbN onto the host substrate. The characteristics of a sputtered film depend on a number of parameters: argon pressure, nitrogen flow rate and time-evolution profile, substrate material, etc. Crucially, the hysteresis in the target voltage as a function of the nitrogen f…
The Collider Detector at Fermilab (CDF) pursues a broad physics program at Fermilab's Tevatron collider. Between Run II commissioning in early 2001 and the end of operations in September 2011, the Tevatron delivered 12 fb-1 of integrated luminosity of p-pbar collisions at sqrt(s)=1.96 TeV. Many physics analyses undertaken by CDF require heavy flavor tagging with large charged particle tracking acceptance. To realize these goals, in 2001 CDF installed eight layers of silicon microstrip detectors around its interaction region. These detectors were designed for 2--5 years of operation, radiation …
We present the results of the first high-altitude balloon flight test of a concept for an advanced Compton telescope making use of modern scintillator materials with silicon photomultiplier (SiPM) readouts. There is a need in the fields of high-energy astronomy and solar physics for new medium-energy gamma-ray (~0.4 - 10 MeV) detectors capable of making sensitive observations. A fast scintillator- based Compton telescope with SiPM readouts is a promising solution to this instrumentation challenge, since the fast response of the scintillators permits the rejection of background via time-of-flig…