We present the results of the first high-altitude balloon flight test of a concept for an advanced Compton telescope making use of modern scintillator materials with silicon photomultiplier (SiPM) readouts. There is a need in the fields of high-energy astronomy and solar physics for new medium-energy gamma-ray (~0.4 - 10 MeV) detectors capable of making sensitive observations. A fast scintillator- based Compton telescope with SiPM readouts is a promising solution to this instrumentation challenge, since the fast response of the scintillators permits the rejection of background via time-of-flight (ToF) discrimination. The Solar Compton Telescope (SolCompT) prototype was designed to demonstrate stable performance of this technology under balloon-flight conditions. The SolCompT instrument was a simple two-element Compton telescope, consisting of an approximately one-inch cylindrical stilbene crystal for a scattering detector and a one-inch cubic LaBr3:Ce crystal for a calorimeter detector. Both scintillator detectors were read out by 2 x 2 arrays of Hamamatsu S11828-3344 MPPC devices. Custom front-end electronics provided optimum signal rise time and linearity, and custom power supplies automatically adjusted the SiPM bias voltage to compensate for temperature-induced gain variations. A tagged calibration source, consisting of ~240 nCi of Co-60 embedded in plastic scintillator, was placed in the field of view and provided a known source of gamma rays to measure in flight. The SolCompT balloon payload was launched on 24 August 2014 from Fort Sumner, NM, and spent ~3.75 hours at a float altitude of ~123,000 feet. The instrument performed well throughout the flight. After correcting for small (~10%) residual gain variations, we measured an in-flight ToF resolution of ~760 ps (FWHM). Advanced scintillators with SiPM readouts continue to show great promise for future gamma-ray instruments.
Development of a Hard X-ray focal plane Compton Polarimeter: A compact polarimetric configuration with Scintillators and Si photomultipliers
宇宙源的X射线偏振测量提供了两个独特的参数,即偏振度和偏振角,可以探测致密物体附近的发射机制和几何形状。具体而言,硬X射线偏振测定法更有价值,因为预期源在较高能量下固有地高度偏振。随着NuSTAR硬X射线光学器件的成功实现,现在可以将康普顿偏振计设想为焦平面探测器。这样的配置很可能在具有宽能带的硬X射线中提供灵敏的偏振测量。我们正在研制一种焦平面硬X射线康普顿偏振计,它由一个塑料闪烁体作为主动散射体,周围是一个CsI(Tl)闪烁体圆柱阵列。散射体为5 mm直径和100 mm长的塑料闪烁体(BC 404),通过普通PMT观察。由塑料散射体散射的光子由16个CsI(Tl)倍增器(5 mm x 5 mm x 150 mm)的圆柱形阵列收集,其由Si光电倍增器(SiPM)读取。新一代SiPM的使用确保了仪器的紧凑性,这对于焦平面探测器的设计至关重要。这种偏振配置的预期灵敏度和塑性散射体的完整表征,特别是在较低能量下,已经在Chattopadhyay等人(Exp. Astron.35,391-412,2013; Astrophys. J.Suppl.212,12,2014)。在本文中,我们描述了耦合到SiPM的CsI(Tl)吸收剂。我们还提出了从完全组装配置的康普顿旋光计的实验结果。
The Department of Physics, The George Washington University(乔治华盛顿大学物理系);NASA Goddard Space Flight Center(美国国家航空航天局戈达德太空飞行中心);Center for Research and Exploration in Space Science and Technology, NASA/GSFC(NASA/GSFC空间科学与技术探索研究中心);University of Maryland at College Park(马里兰大学帕克分校);Catholic University of America(美利坚天主教大学);Wisconsin IceCube Particle Astrophysics Center, University of Wisconsin-Madison(威斯康星大学麦迪逊分校威斯康星IceCube粒子天体物理中心);Space Science Division, Naval Research Laboratory(海军研究实验室空间科学部);Technology Service Corporation(技术服务公司);Los Alamos National Laboratory(洛斯阿拉莫斯国家实验室);University of Maryland, Baltimore County(马里兰大学巴尔的摩县分校);George Mason University, resident at the Naval Research Laboratory(乔治梅森大学(驻海军研究实验室));Center for Space Sciences and Technology, University of Maryland, Baltimore County(马里兰大学巴尔的摩县分校空间科学与技术中心)