A 50 mK test bench for demonstration of the readout chain of Athena/X-IFU
Florent Castellani, Sophie Beaumont, François Pajot, Gilles Roudil, Joseph Adams, Simon Bandler, James Chervenak, Christophe Daniel, Edward V Denison, W Bertran… 展开作者
Florent Castellani, Sophie Beaumont, François Pajot, Gilles Roudil, Joseph Adams, Simon Bandler, James Chervenak, Christophe Daniel, Edward V Denison, W Bertrand Doriese, Michel Dupieux, Malcolm Durkin, Hervé Geoffray, Gene C Hilton, David Murat, Yann Parot, Philippe Peille, Damien Prêle, Laurent Ravera, Carl D Reintsema, Kazuhiro Sakai, Robert W Stevens, Joel N Ullom, Leila R Vale, Nicholas Wakeham
备注:
Proceedings-of-the-SPIE-The-International-Society-for-Optical-Engineering SPIE-Int. Soc. Opt. Eng, In press
The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It will provide unprecedented spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) in the 0.2-12 keV energy range thanks to its array of TES (Transition Edge Sensors) microcalorimeters of more than 2k pixel. The detection chain of the instrument is developed by an international collaboration: the detector array by NASA/GSFC, the cold electronics by NIST, the cold amplifier by VTT, the WFEE (Warm Front-End Electronics) by APC, the DRE (Digital Readout Electronics) by IRAP and a focal plane assembly by SRON. To assess the operation of the complete readout chain of the X-IFU, a 50 mK test bench based on a kilo-pixel array of microcalorimeters from NASA/GSFC has been developed at IRAP in collaboration with CNES. Validation of the test bench has been performed with an intermediate detection chain entirely from NIST and Goddard. Next planned activities include the integration of DRE and WFEE prototypes in order to perform an end-to-end demonstration of a complete X-IFU detection chain.
In the framework of the ESA Athena mission, the X-ray Integral Field Unit (X-IFU) instrument to be on board the X-ray Athena Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors aimed at providing spatially resolved high-resolution spectroscopy. As a part of the on-board Event Processor (EP), the reconstruction software will provide the energy, spatial location and arrival time of the incoming X-ray photons hitting the detector and inducing current pulses on it. Being the standard optimal filtering technique the chosen baseline reconstruction algorithm, …
Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer
Université de Toulouse(图卢兹大学);CNRS(法国国家科学研究中心);IRAP(天体物理研究所);Université de Genève(日内瓦大学);Università degli Studi di Palermo(巴勒莫大学);INAF/Osservatorio Astronomico di Palermo G.S.Vaiana(意大利国家天体物理研究所巴勒莫天文台);CNES(法国国家空间研究中心);Istituto di Astrofisica e Planetologia Spaziali(天体物理学与行星物理学研究所);SRON, Netherlands Institute for Space Research(荷兰空间研究所);Lawrence Livermore National Laboratory(劳伦斯利弗莫尔国家实验室);NASA/Goddard Space Flight Center(美国宇航局戈达德太空飞行中心)
The TES-based Cryogenic AntiCoincidence Detector of ATHENA X-IFU: Validation of the thermal end-to-end simulator towards the updated Demonstration Model (DM 1.1)
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an active area of 1 cm2; the low energy threshold of 20 keV; and the operation connected to a 50 mK thermal bath with a power dissipation less than 40 nW. Here we report the test performed on the first Cry…
The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system ach…
The ATHENA X-IFU development program foresees to build and characterize an instrument Demonstration Model (DM), in order to probe the system critical technologies before the mission adoption. In this respect, we are now developing the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC), which will be delivered to the Focal Plane Assembly (FPA) development team for the integration with the TES array. Before the delivery, we will characterize and test the CryoAC DM in our CryoLab at INAF/IAPS. In this paper we report the main results of the activities performed to improve our cryogenic t…
We present a test platform for the Athena X-IFU detection chain, which will serve as the first demonstration of the representative end-to-end detection and readout chain for the X-IFU, using prototypes of the future flight electronics and currently available subsystems. This test bench, housed in a commercial two-stage ADR cryostat, includes a focal plane array placed at the 50 mK cold stage of the ADR with a kilopixel array of transition-edge sensor microcalorimeter spectrometers and associated cold readout electronics. Prototype room temperature electronics for the X-IFU provide the readout,…
Optimising the multiplex factor of the frequency domain multiplexed readout of the TES-based microcalorimeter imaging array for the X-IFU instrument on the Athena Xray observatory
The X-ray Integral Field Unit (X-IFU) that will be on board the Athena telescope will provide an unprecedented view of the intracluster medium (ICM) kinematics through the observation of gas velocity, $v$, and velocity dispersion, $w$, via centroid-shift and broadening of emission lines, respectively. The improvement of data quality and quantity requires an assessment of the systematics associated with this new data analysis, namely biases, statistical and systematic errors, and possible correlations between the different measured quantities. We have developed an end-to-end X-IFU simulator tha…
We present the design and implementation of a thermal model, developed in COMSOL, aiming to probe the wafer-scale thermal response arising from realistic rates and energies of cosmic rays at L2 impacting the detector wafer of Athena X-IFU. The wafer thermal model is a four-layer 2D model, where 2 layers represent the constituent materials (Si bulk and Si$_{3}$N$_{4}$ membrane), and 2 layers represent the Au metallization layer's phonon and electron temperatures. We base the simulation geometry on the current specifications for the X-IFU detector wafer, and simulate cosmic ray impacts using a s…
Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now producing the CryoAC Demonstration Model (DM): a single pixel prototype able to probe the detector critical technologies, i.e. the operation at 50 mK thermal bath, the threshold energy at 20 keV and the reproducibility of the thermal conductance between the suspended absorber and the thermal bath. This detector will be integrated and tested in our cryogenic s…
At low redshifts, the observed baryonic density falls far short of the total number of baryons predicted. Cosmological simulations suggest that these baryons reside in filamentary gas structures, known as the warm-hot intergalactic medium (WHIM). As a result of the high temperatures of these filaments, the matter is highly ionised such that it absorbs and emits far-UV and soft X-ray photons. Athena, the proposed European Space Agency X-ray observatory, aims to detect the `missing' baryons in the WHIM up to redshifts of $z=1$ through absorption in active galactic nuclei and gamma-ray burst afte…
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of ESA's Athena X-ray observatory. It will deliver X-ray data in the 0.2-12 keV band with an unprecedented spectral resolution of 2.5 eV up to 7 keV. During the observation of very bright X-ray sources, the X-IFU detectors will receive high photon rates. The count rate capability of the X-IFU will be improved by using the defocusing option, which will enable the observations of extremely bright sources with fluxes up to $\simeq 1$ Crab. In the defocused mode, the point spread function (PSF) of the telescope will be…
X-ray observations are limited by the background, due to intrinsic faintness or diffuse nature of the sources. The future Athena X-ray observatory has among its goals the characterization of these sources. We aim at characterizing the particle-induced background of the Athena microcalorimeter, in both its low (Soft Protons) and high (GCR) energy induced components, to assess the instrument capability to characterize background dominated sources such as the outskirts of clusters of galaxies. We compare two radiation environments, namely the L1 and L2 Lagrangian points, and derive indications ag…
The ATHENA X-ray Observatory is the second large-class mission in the ESA Cosmic Vision 2015-2025 science programme. One of the two on-board instruments is the X-IFU, an imaging spectrometer based on a large array of TES microcalorimeters. To reduce the particle-induced background, the spectrometer works in combination with a Cryogenic Anticoincidence detector (CryoAC), placed less than 1 mm below the TES array. The last CryoAC single-pixel prototypes, namely AC-S7 and AC-S8, are based on large area (1 cm2) Silicon absorbers sensed by 65 parallel-connected iridium TES. This design has been ado…
Frequency domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC bias) at MHz frequencies. Using high-quality factor LC filters and room temperature electronics developed at SRON and low-noise two-stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have achieved a performance requested for the demonstration model (DM…
ATHENA is a large-class ESA mission selected for launch in 2031. It is designed to address the science theme "The Hot and Energetic Universe", performing X-ray observations (0.2-12 keV) at the L2 Sun-Earth Lagrangian point. The X-IFU is one of the two instruments of the payload. It is a cryogenic spectrometer providing spatially resolved high-resolution spectroscopy. The core of the instrument is a large array of TES microcalorimeters, operated at a 50 mK thermal bath. The X-IFU performances would be strongly degraded by the particle background expected in the L2 environment, thus advanced red…
Global warming imposes us to reflect on the way we carry research, embarking on the obligation to minimize the environmental impact of our research programs, with the reduction of our travel footprint being one of the easiest actions to implement, thanks to the advance of digital technology. The X-ray Integral Field Unit (X-IFU), the cryogenic spectrometer of the Athena space X-ray observatory of the European Space Agency will be developed by a large international consortium. The travel footprint associated with the development of the X-IFU is to be minimized. For that purpose, a travel footpr…
Active Galactic Nuclei (AGN) display complex X-ray spectra which exhibit a variety of emission and absorption features, that are commonly interpreted as a combination of i) a relativistically smeared reflection component, resulting from the irradiation of an accretion disk by a compact hard X-ray source, ii) one or several warm/ionized absorption components produced by AGN-driven outflows crossing our line of sight, and iii) a non relativistic reflection component produced by more distant material. Disentangling these components via detailed model fitting can thus be used to constrain the blac…
With its array of 3840 Transition Edge Sensors (TESs) operated at 90 mK, the X-Ray Integral Field Unit (X-IFU) on board the ESA L2 mission Athena will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV bandpass. The in-flight performance of the X-IFU will be strongly affected by the calibration of the instrument. Uncertainties in the knowledge of the overall system, from the filter transmission to the energy scale, may introduce systematic errors in the data, which could potentially compromise science objectives - notably those involving li…
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5' equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray back…
The Athena X-Ray Integral Field Unit (X-IFU) will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV energy band. It will comprise an array of 3840 superconducting Transition Edge Sensors (TESs) operated at 90 mK, with an absolute energy scale accuracy of 0.4 eV. Slight changes in the TES operating environment can cause significant variations in its energy response function, which may result in degradation of the detector's energy resolution, and eventually in systematic errors in the absolute energy scale if not properly corrected. These c…
The properties (temperature, density, chemical composition, velocity) of hot astrophysical plasma and the physical processes affecting them (heating/cooling, turbulence, shocks, acceleration) can be probed by high resolution X-ray spectroscopy, to be complemented by high spatial resolution imaging. The paper presents a status of the ESA's Advanced Telescope for High Energy Astrophysics (Athena) mission, particularly focusing on the science performance of its two focal plane instruments for the studies of extended X-ray sources: the Wide Field Imager (WFI) and the X-ray Integral Field Unit (X-I…
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement…
We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray micro-calorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a 8$\times$8 and a 32$\times$32 "kilo-pixel" uniform array. The amount of crosstalk is evaluated as the ratio between the averaged crosstalk signal and the X-ray pulse amplitudes. The crosstalk ratios (CR) for our detectors are compliant with the requirements for future X-ray space missions, such as Athena X-IFU (CR$< 10^{-3}$ for first-neighbour pixels): we measu…
In the early 2030s, ESAs new X-ray observatory, Athena, is scheduled to be launched. It will carry two main instruments, one of which is the X-ray Integral Field Unit (X-IFU), an X-ray imaging spectrometer, which will consist of an array of several thousand transition-edge sensors (TESs) with a proposed energy resolution of 2.5 eV for photon energies up to 7 keV. At SRON we develop the backup TES array based on Ti/Au bilayers with a transition temperature just below 100 mK. In this contribution we will give a broad overview of the properties and capabilities of these state-of-the-art detectors…
We present a characterization of the sensitivity of TES X-ray micro-calorimeters to environmental conditions under frequency-domain multiplexing (FDM) readout. In the FDM scheme, each TES in a readout chain is in series with a LC band-pass filter and AC biased with an independent carrier at MHz range. Using TES arrays, cold readout circuitry and warm electronics fabricated at SRON and SQUIDs produced at VTT Finland, we characterize the sensitivity of the detectors to bias voltage, bath temperature and magnetic field. We compare our results with the requirements for the Athena X-IFU instrument,…
We report our most recent progress and demonstration of a frequency domain multiplexing (FDM) readout technology for transition-edge sensor (TES) arrays, both of which we have been developing, in the framework of the X-IFU instrument on board the future Athena X-ray telescope. Using Ti/Au TES micro-calorimeters, high-Q LC filters and analog/digital electronics developed at SRON and low-noise two-stage SQUID amplifiers from VTT Finland, we demonstrated feasibility of our FDM readout technology, with the simultaneous readout of 37 pixels with an energy resolution at of 2.23 eV at an energy of 6 …
We are developing a kilo-pixels Ti/Au TES array as a backup option for Athena X-IFU. Here we report on single-pixel performance of a 32$\times$32 array operated in a Frequency Division Multiplexing (FDM) readout system, with bias frequencies in the range 1-5 MHz. We have tested the pixels response at several photon energies, by means of a $^{55}$Fe radioactive source (emitting Mn-K$α$ at 5.9 keV) and a Modulated X-ray Source (MXS, providing Cr-K$α$ at 5.4 keV and Cu-K$α$ at 8.0 keV). First, we report the procedure used to perform the detector energy scale calibration, usually achieving a calib…
Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led by ESA and foreseen to be launched in 2031. In this contribution, we report on the development and the characterization of a uniform 32$\times$32 pixel array with (length$\times $width) 140$\times$30 …
The Dyn-Atmo Survey: High-contrast Imaging Spectroscopy of the Substellar Companion HD 13724 B with the JWST NIRSpec IFU
Space Telescope Science Institute(太空望远镜科学研究所);Trinity College Dublin, The University of Dublin(都柏林三一学院,都柏林大学);European Space Agency (ESA)(欧洲空间局(ESA));Amherst College(阿默斯特学院);American Museum of Natural History(美国自然历史博物馆);University of Texas at Austin(德克萨斯大学奥斯汀分校);University of California, San Diego(加利福尼亚大学圣地亚哥分校);Northwestern University(西北大学);University of California, Santa Barbara(加利福尼亚大学圣塔芭芭拉分校);University of California, Santa Cruz(加利福尼亚大学圣克鲁兹分校);University of Massachusetts Amherst(马萨诸塞大学阿默斯特分校);Johns Hopkins University(约翰斯·霍普金斯大学);Smith College(史密斯学院);University of California, Los Angeles(加利福尼亚大学洛杉矶分校)
Simulation-based inference with neural posterior estimation applied to X-ray spectral fitting II -- High-resolution spectroscopy with the X-ray Integral Field Unit
In this multi-messenger astronomy era, all the observational probes are improving their sensitivities and overall performance. The Focusing on Relativistic universe and Cosmic Evolution (FORCE) mission, the product of a JAXA/NASA collaboration, will reach a 10 times higher sensitivity in the hard X-ray band ($E >$ 10~keV) in comparison with any previous hard X-ray missions, and provide simultaneous soft X-ray coverage. FORCE aims to be launched in the early 2030s, providing a perfect hard X-ray complement to the ESA flagship mission Athena. FORCE will be the most powerful X-ray probe for disco…