Progress in the development of frequency domain multiplexing for the X-ray Integral Field Unit on board the Athena mission
H. Akamatsu, L. Gottardi, J. van der Kuur, C. P. de Vries, M. P. Bruijn, J. A. Chervenak, M. Kiviranta, A. J. van den Linden, B. D. Jackson, A. Miniussi, K. Rav… 展开作者
H. Akamatsu, L. Gottardi, J. van der Kuur, C. P. de Vries, M. P. Bruijn, J. A. Chervenak, M. Kiviranta, A. J. van den Linden, B. D. Jackson, A. Miniussi, K. Ravensberg, K. Sakai, S. J. Smith, N. Wakeham
备注:
7 pages, 5 figures. Published on Journal of Low Temperature Physics (2020)
Frequency domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC bias) at MHz frequencies. Using high-quality factor LC filters and room temperature electronics developed at SRON and low-noise two-stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have achieved a performance requested for the demonstration model (DM) with the single pixel AC bias ($ΔE=$1.8 eV) and 9 pixel multiplexing ($ΔE=$2.6 eV) modes. We have also demonstrated 14-pixel multiplexing with an average energy resolution of 3.3 eV, which is limited by non-fundamental issues related to FDM readout in our lab setup.
Athena is the large mission selected by ESA in 2013 to investigate the science theme "Hot and Energetic Universe" and presently scheduled for launch in 2028. One of the two instruments located at the focus of the 12 m-long Athena telescope is the X-ray Integral Field Unit (X-IFU). This is an array of TES micro-calorimeters that will be operated at temperatures of 50 mK in order to perform high resolution spectroscopy with an energy resolution down to 2.5 eV at energies < 7 keV. In order to cope with the large dynamical range of X-ray fluxes spanned by the celestial objects Athena will be obser…
We are developing the frequency domain multiplexing (FDM) read-out of transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field Unit (X-IFU) instrument on board of the future European X-Ray observatory Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a high quantum efficiency ($>$90 \%) and spectral resolution $ΔE$=2.5 eV $@$ 7 keV ($E/ΔE\sim$2800). FDM is currently the baseline readout system for the X-IFU instrument. Using high quality factor LC filters and room temperature electronics developed at SRON and low-noise two stage SQUID amplifiers provi…
The Advanced Telescope for High-Energy Astrophysics (Athena) has been selected by ESA as its second large-class mission. The future European X-ray observatory will study the hot and energetic Universe with its launch foreseen in 2028. Microcalorimeters based on superconducting Transition-edge sensor (TES) are the chosen technology for the detectors array of the X-ray Integral Field Unit (X-IFU) on board of Athena. The X-IFU is a 2-D imaging integral-field spectrometer operating in the soft X-ray band (0.3 -12 keV). The detector consists of an array of 3840 TESs coupled to X-ray absorbers and r…
In the framework of the ESA Athena mission, the X-ray Integral Field Unit (X-IFU) instrument to be on board the X-ray Athena Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors aimed at providing spatially resolved high-resolution spectroscopy. As a part of the on-board Event Processor (EP), the reconstruction software will provide the energy, spatial location and arrival time of the incoming X-ray photons hitting the detector and inducing current pulses on it. Being the standard optimal filtering technique the chosen baseline reconstruction algorithm, …
The TES-based Cryogenic AntiCoincidence Detector of ATHENA X-IFU: Validation of the thermal end-to-end simulator towards the updated Demonstration Model (DM 1.1)
X-ray transients are among the most enigmatic objects in the cosmic sky. The unpredictability and underlying nature of their transient behavior has prompted much study in recent years. While significant progress has been made in this field, a more complete understanding of such events is often hampered by the delay in the rapid follow-up of any transient event. An efficient way to mitigate this constraint would be to devise a way for near real time detection of such transient phenomena. The Athena/Wide Field Imager (WFI), with its $40' \times 40'$ field of view and large effective area, will d…
Both the interplanetary space and the Earth magnetosphere are populated by low energy ($\leq300$ keV) protons that are potentially able to scatter on the reflecting surface of Wolter-I optics of X-ray focusing telescopes and reach the focal plane. This phenomenon, depending on the X-ray instrumentation, can dramatically increase the background level, reducing the sensitivity or, in the most extreme cases, compromising the observation itself. The use of a magnetic diverter, deflecting protons away from the field of view, requires a detailed characterization of their angular and energy distribut…
We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray micro-calorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a 8$\times$8 and a 32$\times$32 "kilo-pixel" uniform array. The amount of crosstalk is evaluated as the ratio between the averaged crosstalk signal and the X-ray pulse amplitudes. The crosstalk ratios (CR) for our detectors are compliant with the requirements for future X-ray space missions, such as Athena X-IFU (CR$< 10^{-3}$ for first-neighbour pixels): we measu…
The Xilinx ZCU111 Radio Frequency System on Chip (RFSoC) is a promising solution for reading out large arrays of microwave kinetic inductance detectors (MKIDs). The board boasts eight on-chip 12-bit / 4.096 GSPS analogue-to-digital converters (ADCs) and eight 14-bit / 6.554 GSPS digital-to-analogue converters (DACs), as well as field programmable gate array (FPGA) resources of 930,000 logic cells and 4,272 digital signal processing (DSP) slices. While this is sufficient data converter bandwidth for the readout of 8,000 MKIDs, with a 2 MHz channel-spacing, and a 1 MHz sampling rate (per channel…
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250μm squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with different wiring topology to mitigate the self-magnetic field. The design is tailored to optimise the performance under Frequency Domain Multiplexing. In this paper we review the main design feature of th…
We analyzed the unexposed to the sky outFOV region of the MOS2 detector on board XMM-Newton covering 15 years of data amounting to 255 Ms. We show convincing evidence that the origin of the unfocused background in XMM-Newton is due to energetic protons, electrons and hard X-ray photons. Galactic Cosmic Rays are the main contributors as shown by the tight correlation (2.6% of total scatter) with 1 GeV protons data of the SOHO EPHIN detector. Tight correlations are found with a proxy of the Chandra background rate, revealing the common source of background for detectors in similar orbits, and wi…
Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer
Université de Toulouse(图卢兹大学);CNRS(法国国家科学研究中心);IRAP(天体物理研究所);Université de Genève(日内瓦大学);Università degli Studi di Palermo(巴勒莫大学);INAF/Osservatorio Astronomico di Palermo G.S.Vaiana(意大利国家天体物理研究所巴勒莫天文台);CNES(法国国家空间研究中心);Istituto di Astrofisica e Planetologia Spaziali(天体物理学与行星物理学研究所);SRON, Netherlands Institute for Space Research(荷兰空间研究所);Lawrence Livermore National Laboratory(劳伦斯利弗莫尔国家实验室);NASA/Goddard Space Flight Center(美国宇航局戈达德太空飞行中心)
Athena is a space-based X-ray observatory intended for exploration of the hot and energetic universe. One of the science instruments on Athena will be the X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer, based on a large cryogenic imaging array of Transition Edge Sensors (TES) based microcalorimeters operating at a temperature of 100mK. The imaging array consists of 3800 pixels providing 2.5 eV spectral resolution, and covers a field of view with a diameter of of 5 arc minutes. Multiplexed readout of the cryogenic microcalorimeter array is essential to comply with …
We report our most recent progress and demonstration of a frequency domain multiplexing (FDM) readout technology for transition-edge sensor (TES) arrays, both of which we have been developing, in the framework of the X-IFU instrument on board the future Athena X-ray telescope. Using Ti/Au TES micro-calorimeters, high-Q LC filters and analog/digital electronics developed at SRON and low-noise two-stage SQUID amplifiers from VTT Finland, we demonstrated feasibility of our FDM readout technology, with the simultaneous readout of 37 pixels with an energy resolution at of 2.23 eV at an energy of 6 …
The X-ray integral field unit for the Athena mission consists of a microcalorimeter transition edge sensor pixel array. Incoming photons generate pulses which are analyzed in terms of energy, in order to assemble the X-ray spectrum. Usually this is done by means of optimal filtering in either time or frequency domain. In this paper we investigate an alternative method by means of principle component analysis. This method attempts to find the main components of an orthogonal set of functions to describe the data. We show, based on simulations, what the influence of various instrumental effects …
Digital Frequency-Domain Multiplexing (DfMux) is a technique that uses MHz superconducting resonators and Superconducting Quantum Interference Device (SQUID) arrays to read out sets of Transition Edge Sensors. DfMux has been used by several Cosmic Microwave Background experiments, including most recently POLARBEAR-2 and SPT-3G with multiplexing factors as high as 68, and is the baseline readout technology for the planned satellite mission LiteBIRD. Here, we present recent work focused on improving DfMux readout noise, reducing parasitic impedance, and improving sensor operation. We have achiev…
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate…
We present a characterization of the sensitivity of TES X-ray micro-calorimeters to environmental conditions under frequency-domain multiplexing (FDM) readout. In the FDM scheme, each TES in a readout chain is in series with a LC band-pass filter and AC biased with an independent carrier at MHz range. Using TES arrays, cold readout circuitry and warm electronics fabricated at SRON and SQUIDs produced at VTT Finland, we characterize the sensitivity of the detectors to bias voltage, bath temperature and magnetic field. We compare our results with the requirements for the Athena X-IFU instrument,…
The next generation of space-based mm-wave telescopes, such as JAXA's LiteBIRD mission, require focal planes with thousands of detectors in order to achieve their science goals. Digital frequency-domain multiplexing (dfmux) techniques allow detector counts to scale without a linear growth in wire harnessing, sub-Kelvin refrigerator loads, and other scaling problems. In this paper, we introduce Technology Readiness Level 5 (TRL5) electronics suitable for biasing and readout of LiteBIRD's Transition Edge Sensor (TES) bolometers using dfmux techniques. These electronics sit between the spacecraft…
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically designed electronics, composed of 20 readout boards and hosted in three microTCA crates, has been developed. The implemented solution and the achieved performances are presented in this paper. We find t…
Our understanding of the background of the EPIC/pn camera onboard XMM-Newton is incomplete. This affects the study of extended sources and can influence the predictions of the background of future X-ray missions. We provide new results based on the analysis of the largest data set ever used. We focus on the unconcentrated component of the EPIC/pn background - supposedly related to cosmic rays interacting with the telescope. We find that the out-field of view region of the pn detector is actually exposed to the sky. After cleaning from the sky contamination, the unconcentrated background does n…
A digital frequency multiplexing (DfMUX) system has been developed and used to tune large arrays of transition edge sensor (TES) bolometers read out with SQUID arrays for mm-wavelength cosmology telescopes. The DfMUX system multiplexes the input bias voltages and output currents for several bolometers on a single set of cryogenic wires. Multiplexing reduces the heat load on the camera's sub-Kelvin cryogenic detector stage. In this paper we describe the algorithms and software used to set up and optimize the operation of the bolometric camera. The algorithms are implemented on soft processors e…
We propose a concept of multiplexing lobster-eye (MuLE) optics to achieve significant reductions in the number of focal plane imagers in lobster-eye (LE) wide-field X-ray monitors. In the MuLE configuration, an LE mirror is divided into several segments and the X-rays reflected on each of these segments are focused on a single image sensor in a multiplexed configuration. If each LE segment assumes a different rotation angle, the azimuthal rotation angle of a cross-like image reconstructed from a point source by the LE optics identifies the specific segment that focuses the X-rays on the imager…
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5' equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray back…
NASA Goddard Space Flight Center(美国宇航局戈达德太空飞行中心);NASA Jet Propulsion Laboratory(美国宇航局喷气推进实验室);School of Earth and Space Exploration, Arizona State University(亚利桑那州立大学地球与空间探索学院);Department of Physics, Arizona State University(亚利桑那州立大学物理系)
THESEUS is a space mission concept, currently under Phase A study by ESA as candidate M5 mission, aiming at exploiting Gamma-Ray Bursts for investigating the early Universe and at providing a substantial advancement of multi-messenger and time-domain astrophysics. In addition to fully exploiting high-redshift GRBs for cosmology (pop-III stars, cosmic re-ionization, SFR and metallicity evolution up to the "cosmic dawn"), THESEUS will allow the identification and study of the electromagnetic counterparts to sources of gravitational waves which will be routinely detected in the late '20s / early …
Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led by ESA and foreseen to be launched in 2031. In this contribution, we report on the development and the characterization of a uniform 32$\times$32 pixel array with (length$\times $width) 140$\times$30 …
The X-ray Integral Field Unit (X-IFU) is the cryogenic imaging spectrometer on board the future X-ray observatory \textsl{Athena}. With a hexagonal array of 3840 AC-biased Transition Edge Sensors (TES), it will provide narrow-field observations (5$^{\prime}$ equivalent diameter) with unprecedented high spectral resolution (2.5 eV up to 7 keV) over the 0.2 - 12 keV bandpass. Throughout its observations, the X-IFU will face various sources of X-ray background. Specifically, the so-called Non-X-ray Background (NXB) caused by the interaction of high-energy cosmic rays with the instrument, may lead…
We are developing a kilo-pixels Ti/Au TES array as a backup option for Athena X-IFU. Here we report on single-pixel performance of a 32$\times$32 array operated in a Frequency Division Multiplexing (FDM) readout system, with bias frequencies in the range 1-5 MHz. We have tested the pixels response at several photon energies, by means of a $^{55}$Fe radioactive source (emitting Mn-K$α$ at 5.9 keV) and a Modulated X-ray Source (MXS, providing Cr-K$α$ at 5.4 keV and Cu-K$α$ at 8.0 keV). First, we report the procedure used to perform the detector energy scale calibration, usually achieving a calib…
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on board of the Japanese space mission SPICA. The FDM prototype of the instrument requires critical and complex optimizations. For single pixel characterization under AC bias we are developing a simple FDM system working in the frequency range from 1 to 5 MHz, based on the open loop read-out of a linearized two-stage SQUID amplifier and high Q lithographic LC resonators. We describe the details of the experimental set-up required to achieve low powe…
THESEUS is a space mission concept aimed at exploiting Gamma-Ray Bursts for investigating the early Universe and at providing a substantial advancement of multi-messenger and time-domain astrophysics. These goals will be achieved through a unique combination of instruments allowing GRB and X-ray transient detection over a broad field of view (more than 1sr) with 0.5-1 arcmin localization, an energy band extending from several MeV down to 0.3 keV and high sensitivity to transient sources in the soft X-ray domain, as well as on-board prompt (few minutes) follow-up with a 0.7 m class IR telescope…