ATHENA X-IFU的低温反符合探测器:AC-S9向验证模型的初步试验

The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary test of AC-S9 towards the Demonstration Model

Matteo D'Andrea, Claudio Macculi, Andrea Argan, Simone Lotti, Gabriele Minervini, Luigi Piro, Michele Biasotti, Valentina Ceriale, Giovanni Gallucci, Flavio Gat… 展开作者

Matteo D'Andrea, Claudio Macculi, Andrea Argan, Simone Lotti, Gabriele Minervini, Luigi Piro, Michele Biasotti, Valentina Ceriale, Giovanni Gallucci, Flavio Gatti, Guido Torrioli, Angela Volpe

摘要:

我们的团队正在开发ATHENA X射线积分场单元(X-IFU)的低温反符合探测器(CryoAC)。它是一个基于TES的4像素探测器,将放置在主TES阵列探测器下方不到1 mm处。我们现在正在生产CryoAC演示模型(DM):一个能够探测探测器关键技术的单像素原型,即在50 mK热浴下的操作,20 keV的阈值能量以及悬浮吸收体和热浴之间热导的再现性。该探测器将在INAF/IAPS的低温装置中进行集成和测试,然后交付给SRON以集成到X-IFU焦平面组件(FPA)DM中。在本文中,我们报告的CryoAC DM开发的状态,显示与最后开发的原型,即AC-S9获得的主要结果。这是一个类似DM的样品,我们在进行最终蚀刻工艺以悬浮硅吸收体之前对其进行了初步集成和测试。结果是有希望的DM,因为尽管由于没有最终的蚀刻(高的热容量,高的热导率,部分TES表面覆盖)的限制,我们已经能够操作的检测器TB = 50 mK和检测6 keV的光子,从而具有低的能量阈值完全符合我们的要求(20 keV)。

英文摘要:

Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now producing the CryoAC Demonstration Model (DM): a single pixel prototype able to probe the detector critical technologies, i.e. the operation at 50 mK thermal bath, the threshold energy at 20 keV and the reproducibility of the thermal conductance between the suspended absorber and the thermal bath. This detector will be integrated and tested in our cryogenic setup at INAF/IAPS, and then delivered to SRON for the integration in the X-IFU Focal Plane Assemby (FPA) DM. In this paper we report the status of the CryoAC DM development, showing the main result obtained with the last developed prototype, namely AC-S9. This is a DM-like sample, which we have preliminary integrated and tested before performing the final etching process to suspend the silicon absorber. The results are promising for the DM, since despite the limitations due to the absence of the final etching (high thermal capacity, high thermal conductance, partial TES surface coverage), we have been able to operate the detector with TB = 50 mK and to detect 6 keV photons, thus having a low energy threshold fully compatible with our requirement (20 keV).

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑