We present the design and implementation of a thermal model, developed in COMSOL, aiming to probe the wafer-scale thermal response arising from realistic rates and energies of cosmic rays at L2 impacting the detector wafer of Athena X-IFU. The wafer thermal model is a four-layer 2D model, where 2 layers represent the constituent materials (Si bulk and Si$_{3}$N$_{4}$ membrane), and 2 layers represent the Au metallization layer's phonon and electron temperatures. We base the simulation geometry on the current specifications for the X-IFU detector wafer, and simulate cosmic ray impacts using a simple power injection into the Si bulk. We measure the temperature at the point of the instrument's most central TES detector. By probing the response of the system and pulse characteristics as a function of the thermal input energy and location, we reconstruct cosmic ray pulses in Python. By utilizing this code, along with the results of the GEANT4 simulations produced for X-IFU, we produce realistic time-ordered data (TOD) of the temperature seen by the central TES, which we use to simulate the degradation of the energy resolution of the instrument in space-like conditions on this wafer. We find a degradation to the energy resolution of 7 keV X-rays of $\approx$0.04 eV. By modifying wafer parameters and comparing the simulated TOD, this study is a valuable tool for probing design changes on the thermal background seen by the detectors.
At low redshifts, the observed baryonic density falls far short of the total number of baryons predicted. Cosmological simulations suggest that these baryons reside in filamentary gas structures, known as the warm-hot intergalactic medium (WHIM). As a result of the high temperatures of these filaments, the matter is highly ionised such that it absorbs and emits far-UV and soft X-ray photons. Athena, the proposed European Space Agency X-ray observatory, aims to detect the `missing' baryons in the WHIM up to redshifts of $z=1$ through absorption in active galactic nuclei and gamma-ray burst afte…
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of ESA's Athena X-ray observatory. It will deliver X-ray data in the 0.2-12 keV band with an unprecedented spectral resolution of 2.5 eV up to 7 keV. During the observation of very bright X-ray sources, the X-IFU detectors will receive high photon rates. The count rate capability of the X-IFU will be improved by using the defocusing option, which will enable the observations of extremely bright sources with fluxes up to $\simeq 1$ Crab. In the defocused mode, the point spread function (PSF) of the telescope will be…
In the framework of the ESA Athena mission, the X-ray Integral Field Unit (X-IFU) instrument to be on board the X-ray Athena Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors aimed at providing spatially resolved high-resolution spectroscopy. As a part of the on-board Event Processor (EP), the reconstruction software will provide the energy, spatial location and arrival time of the incoming X-ray photons hitting the detector and inducing current pulses on it. Being the standard optimal filtering technique the chosen baseline reconstruction algorithm, …
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an active area of 1 cm2; the low energy threshold of 20 keV; and the operation connected to a 50 mK thermal bath with a power dissipation less than 40 nW. Here we report the test performed on the first Cry…
The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system ach…
X-ray observations are limited by the background, due to intrinsic faintness or diffuse nature of the sources. The future Athena X-ray observatory has among its goals the characterization of these sources. We aim at characterizing the particle-induced background of the Athena microcalorimeter, in both its low (Soft Protons) and high (GCR) energy induced components, to assess the instrument capability to characterize background dominated sources such as the outskirts of clusters of galaxies. We compare two radiation environments, namely the L1 and L2 Lagrangian points, and derive indications ag…
Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer
Université de Toulouse(图卢兹大学);CNRS(法国国家科学研究中心);IRAP(天体物理研究所);Université de Genève(日内瓦大学);Università degli Studi di Palermo(巴勒莫大学);INAF/Osservatorio Astronomico di Palermo G.S.Vaiana(意大利国家天体物理研究所巴勒莫天文台);CNES(法国国家空间研究中心);Istituto di Astrofisica e Planetologia Spaziali(天体物理学与行星物理学研究所);SRON, Netherlands Institute for Space Research(荷兰空间研究所);Lawrence Livermore National Laboratory(劳伦斯利弗莫尔国家实验室);NASA/Goddard Space Flight Center(美国宇航局戈达德太空飞行中心)
The TES-based Cryogenic AntiCoincidence Detector of ATHENA X-IFU: Validation of the thermal end-to-end simulator towards the updated Demonstration Model (DM 1.1)
We present a test platform for the Athena X-IFU detection chain, which will serve as the first demonstration of the representative end-to-end detection and readout chain for the X-IFU, using prototypes of the future flight electronics and currently available subsystems. This test bench, housed in a commercial two-stage ADR cryostat, includes a focal plane array placed at the 50 mK cold stage of the ADR with a kilopixel array of transition-edge sensor microcalorimeter spectrometers and associated cold readout electronics. Prototype room temperature electronics for the X-IFU provide the readout,…
Optimising the multiplex factor of the frequency domain multiplexed readout of the TES-based microcalorimeter imaging array for the X-IFU instrument on the Athena Xray observatory
The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It will provide unprecedented spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) in the 0.2-12 keV energy range thanks to its array of TES (Transition Edge Sensors) microcalorimeters of more than 2k pixel. The detection chain of the instrument is developed by an international collaboration: the detector array by NASA/GSFC, the cold electroni…
Global warming imposes us to reflect on the way we carry research, embarking on the obligation to minimize the environmental impact of our research programs, with the reduction of our travel footprint being one of the easiest actions to implement, thanks to the advance of digital technology. The X-ray Integral Field Unit (X-IFU), the cryogenic spectrometer of the Athena space X-ray observatory of the European Space Agency will be developed by a large international consortium. The travel footprint associated with the development of the X-IFU is to be minimized. For that purpose, a travel footpr…
Active Galactic Nuclei (AGN) display complex X-ray spectra which exhibit a variety of emission and absorption features, that are commonly interpreted as a combination of i) a relativistically smeared reflection component, resulting from the irradiation of an accretion disk by a compact hard X-ray source, ii) one or several warm/ionized absorption components produced by AGN-driven outflows crossing our line of sight, and iii) a non relativistic reflection component produced by more distant material. Disentangling these components via detailed model fitting can thus be used to constrain the blac…
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement…
ATHENA is a large-class ESA mission selected for launch in 2031. It is designed to address the science theme "The Hot and Energetic Universe", performing X-ray observations (0.2-12 keV) at the L2 Sun-Earth Lagrangian point. The X-IFU is one of the two instruments of the payload. It is a cryogenic spectrometer providing spatially resolved high-resolution spectroscopy. The core of the instrument is a large array of TES microcalorimeters, operated at a 50 mK thermal bath. The X-IFU performances would be strongly degraded by the particle background expected in the L2 environment, thus advanced red…
We give an overview of the SImulation of X-ray TElescopes (SIXTE) software package, a generic, mission-independent Monte Carlo simulation toolkit for X-ray astronomical instrumentation. The package is based on a modular approach for the source definition, the description of the optics, and the detector type such that new missions can be easily implemented. The targets to be simulated are stored in a flexible input format called SIMPUT. Based on this source definition, a sample of photons is produced and then propagated through the optics. In order to model the detection process, the software t…
In the early 2030s, ESAs new X-ray observatory, Athena, is scheduled to be launched. It will carry two main instruments, one of which is the X-ray Integral Field Unit (X-IFU), an X-ray imaging spectrometer, which will consist of an array of several thousand transition-edge sensors (TESs) with a proposed energy resolution of 2.5 eV for photon energies up to 7 keV. At SRON we develop the backup TES array based on Ti/Au bilayers with a transition temperature just below 100 mK. In this contribution we will give a broad overview of the properties and capabilities of these state-of-the-art detectors…
Thermalization of a SQUID chip at cryogenic temperature: Thermal conductance measurement for GE 7031 Varnish Glue, Apiezon N Grease and Rubber Cement between 20 and 200 mK
针对 ATHENA X-IFU CryoAC 研发,本文在低于 20 mK 的稀释制冷机冷级上测量 2 mm × 2 mm SQUID 芯片经三种低温粘接材料固定后的热导率,并通过多次热循环考察退化效应。
Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led by ESA and foreseen to be launched in 2031. In this contribution, we report on the development and the characterization of a uniform 32$\times$32 pixel array with (length$\times $width) 140$\times$30 …