Single photon avalanche diode (SPAD) arrays have proven themselves as serious candidates for time of flight positron emission tomography (PET). Discrete readout schemes mitigate the low-noise requirements of analog schemes and offer very fine control over threshold levels and timing pickup strategies. A high optical fill factor is paramount to timing performance in such detectors, and consequently space is limited for closely integrated electronics. Nonetheless, a production, daily used PET scanner must minimize bandwidth usage, data volume, data analysis time and power consumption and therefore requires a real-time readout and data processing architecture as close to the detector as possible. We propose a fully digital, embedded real-time readout architecture for SPAD-based detector. The readout circuit is located directly under the SPAD array instead of within or beside it to remove the fill factor versus circuit capabilities tradeoff. The overall real-time engine reduces transmitted data by a factor of 8 in standard operational mode. Combined with small local memory buffers, this significantly reduces overall acquisition dead time. A prototype device featuring individual readout for 6 scintillator channels was fabricated. Timing readout is provided by a first photon discriminator and a 31 ps time to digital discriminator, while energy reading and event packaging is done using standard logic in real-time. The dedicated serial output line supports a sustained rate of 170k counts per second (CPS) in waveform mode, while the standard operational mode supports 2.2 MCPS.
Study on Timing Performance of a Readout Circuit for SiPM
近年来,SiPM光电器件在基于飞行时间的正电子发射断层成像(TOF-PET)领域引起了广泛关注。利用它们构造具有良好符合时间分辨率(CTR)的PET探测器一直是研究的热点之一。本文设计了一种基于共基极电流放大器结构的SiPM读出前置放大器,并在前置放大器的基础上引入了零极点(PZ)补偿网络,研究了影响PET探测器时序性能的主要因素。通过实验测量,我们发现CTR与放大器带宽、SiPM偏置电压、比较器阈值以及PZ网络参数有很大关系。测试装置有两个检测器,一个带有与Hamamatsu SiPM(S12642-0404)耦合的LYSO晶体(3 mm 3 mm 10 mm),另一个带有与PMT-R9800耦合的LaBr 3。通过对读出电路的优化设计,得到了两个探测器之间的CTR为266 ps的半高宽。测试结果为下一步读出ASIC芯片的设计提供了指导。
PETALO read-out: A novel approach for data acquisition systems in PET applications
PETALO(a Positron Emission Tof Apparatus based on Liquid XenOn)是一种基于液体氙的正电子发射断层成像新方法。PETALO探测器的目的是利用其均匀的响应和连续性来捕获由闪烁产生的光。与其他PET探测器相比,该策略将导致无几何失真行为。为此,选择用于光读出的传感器是SiPM,其提供大面积、高增益和非常低的噪声。为了利用PETALO探测器的独特特性,读出架构必须设计为满足以下规格:与探测器相关的电子设备(前端和读出本身)必须在探测器尺寸方面完全可扩展。读出方案必须与探测器的非分段结构兼容。飞行时间(TOF)的能力必须在扫描器级别得到保证,也就是说,前端和读出电子设备不应降低LIFE时间性能。在这些程序中,引入了一种新的读出概念,它与PETALO等完全连续的介质探测器兼容。结果表明,该系统是可行的,与快速压缩技术的引入,以进一步降低数据带宽的要求。
Miniaturized high-frequency sine wave gating InGaAs/InP single-photon detector
高频选通InGaAs/InP单光子探测器(SPD)广泛用于需要在近红外区域中进行单光子探测的应用,例如量子密钥分发。减小SPD的尺寸是实际应用的迫切需要,这有利于进一步实现系统集成。在此,我们将介绍据我们所知最紧凑的高频正弦波选通(SWG)InGaAs/InP SPD。设计并制作了优化半导体结构的InGaAs/InP单光子雪崩二极管(SPAD),并将SPAD芯片和微型热电制冷器封装在尺寸为12.5 mm $\times$ 22 mm $\times$ 10 mm的蝶形封装内。我们实现了SWG SPD的单片读出电路,以取代先前设计的板-水平整合。最后,将SPAD器件、单片读出电路和附属电路集成到一个尺寸为13 cm $\times$ 8 cm $\times$ 4 cm的模块中。与2012年设计的1.25 GHz SWG InGaAs/InP SPD模块(25 cm $\times$ 10 cm $\times$ 33 cm)相比,我们的小型化SPD体积减小了95%。在243K、1.25GHz选通率、100ns延迟时间条件下,探测器的光子探测效率为30%,暗计数率为2.0kcps,后脉冲概率为8.8%。此外,我们进行了一个多星期的稳定性测试,结果表明,小型化的SPD模块的高可靠性。
Measurement of the free ion yield and estimate of the electron mobility of Trimethyl-Bismuth (TMBi)
European Institute for Molecular Imaging, University of Münster(明斯特大学欧洲分子成像研究所);Institute for Nuclear Physics, University of Münster(明斯特大学核物理研究所);BioMAPs, Service Hospitalier Frédéric Joliot, CEA, CNRS, Inserm, Université Paris-Saclay(萨克雷大学CEA/CNRS/Inserm弗雷德里克·约里奥医院生物医学平台)
108 ps coincidence time resolution through optimized scintillators, photodetectors, readout electronics, and DOI-based timing correction in orthogonally stacked detector configurations
Central Research Laboratory, Hamamatsu Photonics K. K.(滨松光子株式会社中央研究实验室)
Development of a high-granularity, high-precision timing readout electronics system for large-area MRPC detectors
Institute of Nuclear and Particle Physics, School of Physics and Astronomy, Shanghai Jiao Tong University(上海交通大学物理与天文学院核粒子物理研究所);Key Laboratory for Particle Astrophysics and Cosmology (MoE), Shanghai Key Laboratory for Particle Physics and Cosmology(教育部粒子天体物理与宇宙学重点实验室,上海粒子物理与宇宙学重点实验室);Institut de Physique des 2 Infinis de Lyon, Lyon University(里昂大学里昂双无限物理研究所);Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所)
本研究针对含2400个2*2 cm pad通道的大面积MRPC探测器,研发了由FEBs、时钟模块、DAQ聚合器及PETIROC2B ASIC组成的高粒度高精度定时读出系统,其单通道时间分辨率达33 ps RMS,可应用于多种定时探测器场景。
An FPGA Based energy correction method for one-to-one coupled PET detector: model and evaluation
基于硅光电倍增器(SiPMs)的PET扫描器已经被广泛用作先进的核医学成像技术,其产生局部体内生物学和生物化学的定量图像。SiPM的紧凑尺寸允许闪烁晶体和光电传感器之间的直接一对一耦合,从而产生比必须在光电倍增管(PMT)PET系统中使用的光共享方法更好的定时和能量分辨率。为了减小读出电子设备的体积,具有位置解码器的前端多路复用器是没有高度集成的专用集成电路(ASIC)的一对一系统的常见选择。然而,在这种情况下,我们不能测量每个晶体的沉积能量激发的湮灭光子,所以晶间散射(ICS)事件将导致晶体错位,然后恶化探测器的固有分辨率。此外,考虑到SiPM的增益色散和非线性输出导致的能量窗口内的事件拒绝,需要能量校正机制。然而,缺乏每个晶体的能量信息将引入大的能量校正误差的ICS事件。针对这一问题,本文提出了一种在Kintext-7现场可编程门阵列(FPGA)器件上实现的在线能量校正机制。实验室中的实验使用8 X 8分段LYSO晶体与8 X 8 SiPM(J系列,来自ON Semiconductor)阵列耦合进行,该阵列在22 Na点源激发下。测试结果表明,非ICS和ICS事件的能量都可以精确校正,能量分辨率优于12%。我们还将此方法应用于实际的临床PET扫描仪下的68 Ge线源,以验证其多通道的可靠性。
Characterisation of the LAPPD, a large area microchannel-plate PMT
Faculty of Chemistry and Chemical Engineering, University of Maribor(马里博尔大学化学与化工学院);Jožef Stefan Institute(约瑟夫斯特凡研究所);Faculty of Mathematics and Physics, University of Ljubljana(卢布尔雅那大学数学与物理学院)
Assessment of a high-resolution candidate detector for prostate time-of-flight positron emission tomography
我们报告使用22 Na源上的MRI兼容的TOF-PET直肠内前列腺探头的探测器元件进行测量,与深度的相互作用的灵敏度。它由LYSO闪烁体晶体制成,用Lumirror包裹,通过硅光电倍增器在两端读出。通过对数据分析过程的详细描述,我们表明我们的结果指向400 ps的重合分辨时间,同时,相互作用深度分辨率为1 mm。这些吸引人的特征,以及微小的1.5 mm x 1.5 mm x 10 mm晶体尺寸,对于原型探针的实现来说非常有希望。
Investigating the Timing Behavior of Compton Scattering in BGO for Time-of-Flight PET
Seoul National University(首尔大学);University of California, Davis(加州大学戴维斯分校);Fondazione Bruno Kessler(布鲁诺·凯斯勒基金会);Brightonix Imaging Inc.(Brightonix成像公司)
Light-Based Fast Timing in Bulk CsPbBr3 Crystals for TOF-PET and Proton Range Verification
University of California at Davis (UCD)(加州大学戴维斯分校);I3N-Physics Department, University of Aveiro(阿威罗大学I3N物理系);Actinia, Inc(Actinia公司);Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室);Institut de Fı́sica d’Altes Energies - Barcelona Institute of Science and Technology(高能物理研究所-巴塞罗那科学技术学院)