arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2610.13564physics.ins-det
收藏

三甲基铋(TMBi)的自由离子产额测量与电子迁移率估算

Measurement of the free ion yield and estimate of the electron mobility of Trimethyl-Bismuth (TMBi)

European Institute for Molecular Imaging, University of Münster(明斯特大学欧洲分子成像研究所);Institute for Nuclear Physics, University of Münster(明斯特大学核物理研究所);BioMAPs, Service Hospitalier Frédéric Joliot, CEA, CNRS, Inserm, Université Paris-Saclay(萨克雷大学CEA/CNRS/Inserm弗雷德里克·约里奥医院生物医学平台)

B. Gerke, V. Hannen, S. Peters, C. Huhmann, V. Sharyy, D. Yvon, K. Schäfers, C. Weinheimer

AI总结:

本文测量了液态TMBi的零场自由离子产额并估算其电子迁移率,发现其性能逊于TMSi,质疑其用于PET探测器的适用性,同时提出TMPb或为可行替代方案。

摘要:

本文研究了液态三甲基铋(Trimethyl-Bismuth,TMBi)的物理特性,该特性与填充TMBi的正电子发射断层成像(Positron-Emission-Tomography,PET)探测器的电荷读出相关。高光电效率以及通过探测液态中产生的切伦科夫光实现快定时的可能性,均有利于TMBi在PET系统中的应用。然而,为获得高位置和能量分辨率,还需对511 keV光子吸收产生的电荷信号进行读出,为此液态必须不含电负性和离子杂质。本研究开发了一种蒸馏技术作为去除此类杂质的可行方法之一,并提供了该清洁方法的效率测量结果。高效电荷读出的相关参数为液态的自由离子产额和电子迁移率。我们报告了TMBi中零场自由离子产额的新测量结果,并利用该结果估算了电子迁移率。与四甲基-n化合物(如TMSi)相比,TMBi的零场自由离子产额相当低,且预期电子迁移率低得多,这对三甲基分子TMBi用作PET探测器液态的适用性提出了质疑,但我们也提出论据表明四甲基分子TMPb可能是一种有趣的替代方案。

英文摘要:

This paper investigates the physical characteristics of the liquid Trimethyl-Bismuth (TMBi) relevant for charge readout in potential TMBi filled detectors for Positron-Emission-Tomography (PET) instruments. The high photo-efficiency and the possibility of fast timing by detection of Cherenkov light created in the liquid are both favorable for use of TMBi in a PET system. However, to obtain a high position and energy resolution also a readout of the charge signal created due to the absorption of a 511 keV photon is required. For this purpose the liquid has to be clean of electro-negative and ionic impurities. A distillation technique was developed within this study as one of the possible methods to remove such impurities and a measurement on the efficiency of this cleaning method is provided. The relevant quantities for an efficient charge readout are the free ion yield and the electron mobility of the liquid. We report on a new measurement of the zero-field free ion yield in TMBi and, using that result, produce an estimate of the electron mobility. The rather low zero-field free ion yield and its much lower expected electron mobility compared to tetramethyl-n compounds like TMSi question the use of the trimethyl molecule TMBi for a PET detector liquid. But we are also giving arguments that the tetramethyl molecule TMPb could be an interesting alternative.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑