A PET scanner based on silicon photomultipliers (SiPMs) has been widely used as an advanced nuclear medicine imaging technique that yields quantitative images of regional in vivo biology and biochemistry. The compact size of the SiPM allows direct one to one coupling between the scintillation crystal and the photosensor, yielding better timing and energy resolutions than the light sharing methods that have to be used in photomultiplier tube (PMT) PET systems. To decrease the volume of readout electronics, a front end multiplexer with position decoder is a common choice for the one to one system without a highly integrated application specific integrated circuit (ASIC). However, in this case we cannot measure each crystal's deposited energy inspired by an annihilation photon, so the inter-crystal scatter (ICS) events will lead to the crystal mispositioning and then deteriorate the detector intrinsic resolution. Besides, considering the events rejection within the energy window resulting from the gain dispersion and nonlinear outputs of the SiPMs, an energy correction mechanism is needed. Yet, lack of the information of each crystal's energy will introduce large energy correction error for the ICS events. For this issue, an online energy correction mechanism implemented on a Kintext-7 Field Programmable Gate Array (FPGA) device is presented in this paper. Experiments in the laboratory were performed using an 8 x 8 segmented LYSO crystals coupled with an 8 x 8 SiPM (J-series, from ON Semiconductor) array which is under 22Na point source excitation. Test results indicate that both the energy of the non-ICS and ICS events can be precisely corrected and the energy resolution is better than 12 %. We also applied this method to an actual clinical PET scanner under a 68Ge line source to verify its multi-channel reliability.
Fully Field Programmable Gate Array (FPGA)based digitizer for high-resolution time and energy measurement is an attractive low cost solution for the readout electronics in positron emission computed tomography (PET)detector. In recent years, the FPGA based time-digital converter (FPGA-TDC) has been widely used for time measurement in the commercial PET scanners. Yet, for the energy measurement, few studies have been reported on a fully FPGA based, large dynamic range and high resolution alternative to the commercial analog-digital converter (ADC). Our previous research presents a 25 Ms/s FPGA-…
The aim of this study is to design and evaluate a simple free running Analog-Digital Converter (ADC) based on the Field Programmable Gate Array (FPGA) device to accomplish the energy and position readout of the silicon photomultiplier (SiPM) array for application as PET scanners. This simple FPGA-ADC based on a carry chain Time-Digital Converter (TDC) implemented on a Kintex-7 FPGA consists of only one off-chip resistor so it has greater advantages in improving system integration and reducing cost than commercial chips. In this paper, a FPGA-ADC based front-end electronics prototype is present…
Small animal Positron Emission Tomography (PET) is dedicated to small animal imaging, which requires high position and energy precision, as well as good flexibility and efficiency of the electronics. This paper presents the design of a digital signal processing logic for a marmoset brain PET system based on LYSO crystal arrays, SiPMs, and the resistive network readout method. We implement 32-channel signal processing in a single Xilinx Artix-7 Field-Programmable Gate Array (FPGA). The logic is designed to support four online modes which are regular data processing mode, flood map construction …
We present an FPGA-based readout chip emulator board for the CMS Endcap Timing Layer (ETL) detector upgrade. The emulator board uses an Intel Cyclone 10 GX FPGA to emulate the digital functions of four Endcap Layer Readout Chips (ETROCs). Based on the actual ETROC design, the firmware is implemented and verified. The emulator board is being used for the ETROC digital design verification and system development.
Small animal Positron Emission Tomography (PET) is dedicated to small animal imaging. Animals used in experiments, such as rats and monkeys, are often much smaller than human bodies, which requires higher position and energy precision of the PET imaging system. Besides, Flexibility, high efficiency are also the major demands of a practical PET system. These requires a high-quality analog front-end and a digital signal processing logic with high efficiency and compatibility of multiple data processing modes. The digital signal processing logic of the small animal PET system presented in this pa…
A prototype of DIRC-like Time-of-Flight detector (DTOF), including a pico-second time measurement electronics, is developed and tested preliminarily. The basic structure of DTOF is composed of a fused silica radiator connected to fast micro-channel plate PMTs (MCP-PMT), and readout by a dedicated FPGA (Field Programmable Gate Array) based front-end electronics. The full electronics chain consists of a programmable differential amplifier, a dual-threshold differential discriminator, and a timestamp Time-to-Digital convertor. By splitting a MCP-PMT output signal into two identical electronics ch…
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead we introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search and Region-Of-Response (ROR) reconstruction by the programmable logic and visualization by the integrat…
Scientific experiments rely on some type of measurements that provides the required data to extract aimed information or conclusions. Data production and analysis are therefore essential components at the heart of any scientific experimental application. Traditionally, efforts on detector development for photon sources have focused on the properties and performance of the detection front-ends. In many cases, the data acquisition chain as well as data processing, are treated as a complementary component of the detector system and added at a late stage of the project. In most of the cases, data …
The analog signals generated in the read-out electronics of radiation detectors are shaped prior to the digitization in order to improve the signal to noise ratio (SNR). The real amplitude of the analog signal is then obtained using digital filters, which provides information about the energy deposited in the detector. The classical digital filters have a good performance in ideal situations with Gaussian electronic noise and no pulse shape distortion. However, high-energy particle colliders, such as the Large Hadron Collider (LHC) at CERN, can produce multiple simultaneous radiation events, w…
The Jagiellonian positron emission tomograph (J-PET) is a multi-purpose device built out of plastic scintillators. With large acceptance and high angular resolution, it is suitable for the studies of various phenomena such as discrete symmetries in decay of positronium atom or entangled states of photons as well as medical imaging. J-PET enables the measurement of momenta together with photon polarization related observables. Large acceptance and high granularity of the J-PET detector enables measurement of ortho-positronium decays into three photons in the whole phase-space. In this paper we …
Lutetium (Lu) based scintillators such as LSO and LYSO, are widely used in modern PET detectors due to their high stopping power for 511 keV gamma rays, high light yield and short decay time. However, 2.6% of naturally occurring Lu is 176Lu, a long-lived radioactive element including a beta decay and three major simultaneous gamma decays. This phenomenon introduces random events to PET systems that affects the system performance. On the other hand, the advantages of intrinsic radiation of 176Lu (IRL) continues to be exploited. In this paper, research literatures about IRL in PET detectors are …
In this work, a serial on-line cluster reconstruction technique based on FPGA technology was developed to compress experiment data and reduce the dead time of data transmission and storage. At the same time, X-ray imaging experiment based on a two-dimensional positive sensitive triple GEM detector with an effective readout area of 10 cm*10 cm was done to demonstrate this technique with FPGA development board. The result showed that the reconstruction technology was practicality and efficient. It provides a new idea for data compression of large spectrometers.
PETALO (a Positron Emission Tof Apparatus based on Liquid xenOn) is a new approach for Positron Emission Tomography scanners, based on liquid xenon. The PETALO detector aims at capturing the light produced by the scintillation in LXe taking advantage of its uniform response and continuity. This strategy will lead to a geometrical distortion free behavior compared to other PET detectors. To this end, the sensors chosen for the light readout are SiPMs, which provide large area, high gain and very low noise. In order to take advantage of the unique PETALO detector characteristics a read-out archi…
A novel PET detector consisting of strips of polymer scintillators is being developed by the J-PET Collaboration. The map of efficiency and the map of geometrical acceptance of the 2-strip J-PET scanner are presented. Map of efficiency was determined using the Monte Carlo simulation software GATE based on GEANT4. Both maps were compared using method based on the chi2 test.
The aim of this work was to test the impact of the lightguides insertion in the J-PET detection system and to choose the best of available solutions. At the two strip J-PET test system a series of measurements was performed with different combinations concerning the length of the lightguides (3 mm and 3 cm) and scintillators (3, 15 and 30 cm), shape of lightguides (trapezoidal and cylindrical, with and without a cut matching the scintillator size) and optical connection between elements (optical gel and glue). It was proven that the insertion of the thin lightguide does not spoil the time reso…
The TT-PET collaboration is developing a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. The electronics exhibit an equivalent noise charge below 600 e- RMS and a pulse rise time of less than 2 ns, in accordance with the simulations. The pixels with a capacitance of 0.8 pF were measured to …
This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration aims to integrate Time-Of-Flight PET with ultrasound endoscopy in a novel multimodal device, capable to support the development of new biomarkers for prostate and pancreatic tumors. The detector consists in two parts: a PET head mounted on an ultrasound probe and an external PET plate. The challenging goal of 1 mm spatial resolution for the PET image requir…
The complexity of the hardware and the amount of data collected during the PET imaging process require application of modern methods of efficient data organization and processing. In this article we will discuss the data structures and the flow of collected data from the novel TOF-PET medical scanner which is being developed at the Jagiellonian University. The developed data format reflects: registration process of the gamma quanta emitted from positron-electron annihilation, Front-End Electronic (FEE) structure and required input information for the image reconstruction. In addition, the syst…
Positron Emission Tomography (PET) using time-of-flight information, which can greatly improve the quality of the reconstructed image, has recently become an exciting topic. In this work, 3.2mm*3.2mm*25mm finger-like LYSO crystals were used to make a 5*5 array, coupled to the Hamamatsu H8500 photomultiplier tube (PMT) as a detector. A fast leading-edge discriminator was designed for the LYSO-H8500 detector. Average coincidence time resolution FWHM of 330 ps was obtained for the LYSO detector with a reference BaF2 detector, whose time resolution for 511 keV γ-rays was FWHM 150 ps. Time resoluti…
This work presents the design and preliminary performance of a highly-multiplexed superconducting detector readout. The readout system is implemented on the Xilinx ZCU111 RFSoC Evaluation Board. The current design uses 12% of the DSPs, 60% of the LUTs, 20% of the FFs, and 30% of the BRAM and makes timing at 512 MHz. The system uses two integrated ADCs and DACs running at 4.096 GSPS to read out 2,048 superconducting detectors. This work targets a 2x increase in the number of superconducting detectors processed per board with 80% less power than previous readout schemes. The open-source design l…
Jagiellonian Positron Emission Tomograph (J-PET) is a multi-purpose detector which will be used for search for discrete symmetries violations in the decays of positronium atoms and for investigations with positronium atoms in life-sciences and medical diagnostics. In this article we present three methods for determination of the beam profile of collimated annihilation gamma quanta. Precise monitoring of this profile is essential for time and energy calibration of the J-PET detector and for the determination of the library of model signals used in the hit-time and hit-position reconstruction. W…
Novel Positron Emission Tomography system, based on plastic scintillators, is developed by the J-PET collaboration. In order to optimize geometrical configuration of built device, advanced computer simulations are performed. Detailed study is presented of background given by accidental coincidences and multiple scattering of gamma quanta.
We report on the development of a novel FPGA-based Time-to-Digital Converter and its implementation in a detection chain that records the coordinates of single particles along three dimensions. The detector is composed of Micro-Channel Plates mounted on top of a cross delay line and connected to fast electronics. We demonstrate continuous recording of the timing signals from the cross delay line at rates up to 4.1x10^6 per second and three-dimensional reconstruction of the coordinates up to 3.2x10^6 particles per second. From the imaging of a calibrated structure we measure the in-plane resolu…
In the upgrade of ATLAS experiment, the front-end electronics components are subjected to a large radiation background. Meanwhile high speed optical links are required for the data transmission between the on-detector and off-detector electronics. The GBT architecture and the Versatile Link (VL) project are designed by CERN to support the 4.8 Gbps line rate bidirectional high-speed data transmission which is called GBT link. In the ATLAS upgrade, besides the link with on-detector, the GBT link is also used between different off-detector systems. The GBTX ASIC is designed for the on-detector fr…
On-detector digital electronics in High-Energy Physics experiments is increasingly being implemented by means of SRAM-based FPGA, due to their capabilities of reconfiguration, real-time processing and multi-gigabit data transfer. Radiation-induced single event upsets in the configuration hinder the correct operation, since they may alter the programmed routing paths and logic functions. In most trigger and data acquisition systems, data from several front-end modules are concentrated into a single board, which then transmits data to back-end electronics for acquisition and triggering. Since th…
Liquid argon time projection chambers (LArTPCs) have been proposed as neutrino detectors that combine both large sizes to maximize the number of neutrino interactions and detailed recording of the interaction. The readout of thousands of channels at MHz sampling rates produce images of the neutrino-nucleus interaction with millimeter-scale resolution, enabling the identification of the resulting particles and offering multiple handles to measure their energies at the expense of large data rates. Continuous acquisition of the LArTPC data is required to enable the use of high-latency triggers fo…
Monolithic crystals are examined as an alternative to segmented scintillator arrays in positron emission tomography (PET). Monoliths provide good energy, timing and spatial resolution including intrinsic depth of interaction (DOI) encoding. DOI allows reducing parallax errors (radial astigmatism) at off-center positions within a PET ring. We present a novel DOI-estimation approach based on the supervised machine learning algorithm gradient tree boosting (GTB). GTB builds predictive regression models based on sequential binary comparisons (decision trees). GTB models have been shown to be imple…
A mini-PET style detector system is being developed for a plant imaging application with a compact array of silicon photomultipliers (SiPM) replacing position sensitive photomultipliers (PSPMT). In addition to compactness, the use of SiPMs will allow imaging setups involving high strength MRI-type magnetic fields. The latter will allow for better position resolution of the initial positron annihilations in the plant tissue. In the present work, prototype arrays are tested for the uniformity of their response as it is known that PSPMTs require significant gain compensation on the individual cha…
PET provides in vivo molecular and functional imaging capability that is crucial to studying the interaction of plant with changing environment at the whole-plant level. We have developed a dedicated plant PET imager that features high spatial resolution, housed in a fully controlled environment provided by a plant growth chamber (PGC). The system currently contains two types of detector modules: 84 microPET R4 block detectors with 2.2 mm crystals to provide a large detecting area; and 32 Inveon block detectors with 1.5 mm crystals to provide higher spatial resolution. Outputs of the four micr…
We present a custom implementation of a 2D Convolutional Neural Network (CNN) as a viable application for real-time data selection in high-resolution and high-rate particle imaging detectors, making use of hardware acceleration in high-end Field Programmable Gate Arrays (FPGAs). To meet FPGA resource constraints, a two-layer CNN is optimized for accuracy and latency with KerasTuner, and network \textit{quantization} is further used to minimize the computing resource utilization of the network. We use "High Level Synthesis for Machine Learning" (\textit{hls4ml}) tools to test CNN deployment on …
To measure light emission pattern in scintillator, higher sensitivity and faster response are required to photo detector. Such as single photon avalanche diode (SPAD), conventional pixelated photo detector is operated at Geiger avalanche multiplication. However higher gain of SPAD seems very attractive, photon detection efficiency per unit area is low. This weak point is mainly caused by Geiger avalanche mechanism. To overcome these difficulties, we designed Pixelated Linear Avalanche Integration Detector using Silicon on Insulator technology (SOI-Plaid). To avoid dark count noise and dead tim…
The aim of this work is to show the potential capabilities of monolithic crystals coupled to large SiPM arrays, to be considered as detector blocks for PET scanners enabling Time Of Flight (TOF) capabilities. Monolithic blocks allow one to decode the 3D photon impact position. This approach, along with TOF information, can be of high interest in clinical Positron emission tomography (PET) applications where a typical ring configuration is used. In this manuscript, we evaluate an ASIC- based readout for digitizing all signals coming from analog photosensors. Validation results with one-to-one c…
New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating medium and UV-sensitive silicon photomultipliers for scintillation readout. The scintillation time in liquid xenon is fast enough to register time-of-flight information for each detected coincidence, and sufficient scintillation is produced with low enough fluctuations to obtain good energy resolution. The present simulation study examines a full-body-sized…
The effect of the intrinsic lutetium radioactivity on the detection performances of a LYSO based in-beam PET prototype used for quality control of hadron therapy treatments is studied. This radioactivity leads to a background that degrades the measurement of the $β$ + signal. In particular, it prevents the measurement of faint signals originating from low activity $β$ + sources. This paper presents a method to estimate the minimum $β$ + activity that can be measured for any acquisition time taking into account the non-extensible dead time of the detector. This method is illustrated with experi…
We are investigating a prototype virtual pinhole positron emission tomography (VP-PET) system for small animal imaging applications. The PET detector modules were made up of 1.3 mm lutetium-yttrium oxyorthosilicate (LYSO) arrays, and the insert detectors consists of 0.6 mm pixelated Cadmium Zinc Telluride (CdZnTe). To validate the imaging experiment, we conducted a Monte Carlo simulation for the VP-PET system in Geant4 Application for Emission Tomography (GATE). For a point source of Na-22 with 0.5 mm diameter, the filtered back-projection (FBP) algorithm reconstructed PET image shows a resolu…
A novel FPGA based online tracking algorithm for helix track reconstruction in a solenoidal field, developed for the PANDA spectrometer, is described. Employing the Straw Tube Tracker detector with 4636 straw tubes, the algorithm includes a complex track finder, and a track fitter. Implemented in VHDL, the algorithm is tested on a Xilinx Virtex-4 FX60 FPGA chip with different types of events, at different event rates. A processing time of 7 $μ$s per event for an average of 6 charged tracks is obtained. The momentum resolution is about 3\% (4\%) for $p_t$ ($p_z$) at 1 GeV/c. Comparing to the al…
J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on the feasibility of such polarization measurements of photons from the decay of positronium with the J-PET and explore the physical limitations for the resolution of the polarization determination of …
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of analysis of the positron lifetime measured in the porous polymer. The obtained results prove that J-PET is capable of performing simultaneous imaging of the density distribution of annihilation points as…
Novel TOF-PET scanner solutions demand, apart from the state of the art detectors, software for fast processing of the gathered data, monitoring of the whole scanner and reconstruction of the PET image. In this article we present an analysis framework for the novel STRIP-PET scanner developed by the J-PET collaboration in the Institute of Physics of the Jagiellonian University. This software is based on the ROOT package used in many particle physics experiments.
PETALO (Positron Emission TOF Apparatus based on Liquid xenOn) exploits the unique characteristics of liquid xenon as a scintillator for use in a PET detector. Here initial simulation studies are detailed which highlight the potential of such a detector and outline the steps taken in the reconstruction of 511 keV gamma rays and in the full PET image reconstruction. In particular, a neural network-based approach is conceived in order to tag gamma rays that are poorly reconstructed due to Compton scattering. It is found that though a significant fraction of events undergo Compton scattering, not…
Digital off-detector electronics in trigger and data acquisition systems of High-Energy Physics experiments is often implemented by means of SRAM-based FPGAs, which make it possible to achieve reconfigurable, real-time processing and multi-gigabit serial data transfers. On-detector usage of such devices is mostly limited by their configuration sensitivity to radiation-induced upsets, which may alter the programmed routing paths and configurable elements. In this work, we show a new technique for enhancing the usage of SRAM-based FPGAs also for on-detector applications. We show a demonstrator o…
The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pur- sue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET enables the measurement of both momenta and the polarization vectors of annihilation photons. The latter is a unique feature of the J-PET detector which allows the study of time reversal symmetry vio…
One of the features of the triplet state of positronium (ortho-Positronium)atoms is its relatively longer lifetime when compared to the singlet states ofpositronium (para-Positronium) atoms. The most probable decay of ortho-Positronium is into three annihilation photons. In order to test the discretesymmetry using the time-reversal symmetry odd-operator, it is importantto identify ortho-Positronium decay. Identification of the decay of ortho-Positronium atoms by measuring the positronium annihilation lifetime withthe Jagiellonian-Positron Emission Tomograph (J-PET) is presented in this article…
Presice measurements of the photons conversion points in the scintillators are required to achieve a high spatial resolution of the PET system. I have developed a new method of reconstruction of the depth-of-interaction information for PET detectors with dual-side readout. The depth-of-interaction and energy resolutions from Monte-Carlo simulations are presented in this paper. The new method allows to reach depth-of-interaction resolution that is about 0.4~mm ($σ$) [or about 1.0~mm (FWHM)] for 10-mm long LYSO scintillator. If the precise measurement of the primary photon energy is not a high p…
According to current prognosis studies of pancreatic cancer, survival rate nowadays is still as low as 6% mainly due to late detections. Taking into account the location of the disease within the body and making use of the level of miniaturization in radiation detectors that can be achieved at the present time, EndoTOFPET-US collaboration aims at the development of a multimodal imaging technique for endoscopic pancreas exams that combines the benefits of high resolution metabolic information from Time-Of- Flight (TOF) Positron Emission Tomography (PET) and anatomical information from ultrasoun…
Positronium is a unique laboratory to study fundamental symmetries in the Standard Model, reflection in space ($\mathcal{P}$), reversal in time ($\mathcal{T}$), charge conjugation ($\mathcal{C}$) and their combinations. The experimental limits on the $\mathcal{C}$, $\mathcal{CP}$ and $\mathcal{CPT}$ symmetries violation in the decays of positronium are still several orders of magnitude higher than the expectations. The newly constructed Jagiellonian Positron Emission Tomograph (J-PET) was optimized for the registration of photons from the electron-positron annihilations. It enables tests of di…
Transforming the resistive plate chambers from charged-particle into gamma-quanta detectors opens the way towards their application as a basic element of a hybrid imaging system, which combines positron emission tomography (PET) with magnetic resonance imaging (MRI) in a single device and provides non- and minimally- invasive quantitative methods for diagnostics. To this end, we performed detailed investigations encompassing the whole chain from the annihilation of the positron in the body, through the conversion of the created photons into electrons and to the optimization of the electron yie…
The Jagiellonian-PET (J-PET) collaboration is developing a prototype TOF-PET detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast, FPGA-based front-end electronics and the data acquisition system, as well as, low- and high-level reconstruction algorithms were specially developed to be used with the J-PET scanner. The TOF-PET data processing and reconstruction are time and resource demanding operations, especially in case of a large acceptance detector, wh…