Database and data structure for the novel TOF-PET detector developed for J-PET project
E. Czerwiński, M. Zieliński, T. Bednarski, P. Białas, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Molenda,… 展开作者
E. Czerwiński, M. Zieliński, T. Bednarski, P. Białas, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Molenda, P. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki, A. Wieczorek, W. Wiślicki, N. Zoń
备注:
6 p, 3 figs, based on talk given at Symposium on Positron Emission Tomography, Sept. 19-22, 2013, Jagiellonian University, Kraków PL, submitted to Bio-Algorithms and Med-Systems
发表信息:
Bio-Algorithms and Med-Systems 10(2), 79-83 (2014)
The complexity of the hardware and the amount of data collected during the PET imaging process require application of modern methods of efficient data organization and processing. In this article we will discuss the data structures and the flow of collected data from the novel TOF-PET medical scanner which is being developed at the Jagiellonian University. The developed data format reflects: registration process of the gamma quanta emitted from positron-electron annihilation, Front-End Electronic (FEE) structure and required input information for the image reconstruction. In addition, the system database fulfills possible demands of the evolving J-PET project.
Near 65ps-fwhm in 20mm-LSO TOF-PET by using a time walk correction based on multi-photon stamps: a Monte Carlo study
目的:研究基于晶体光共享和多光子时间戳的时间游走评估是否可以提高TOF分辨率。方法:对SiPM(FBK-NUV-HD)进行蒙特卡罗模拟,SiPM(FBK-NUV-HD)耦合到传统的4 × 4 mm 2像素化LSO(0.2%Ca:Ce),并且还耦合到8 × 4 mm 2像素化LSO,其中三角形光学窗口允许根据DOI在两个4 × 4 mm 2子像素之间共享光。时间游走估计被建模为光子检测序列内的时间差的DOI相关加权和。为了获得最佳的TOF分辨率,对DOI相关权重进行了优化。结果:观察到两个4x 4 mm 2子像素之间的光共享的强线性DOI依赖性。4x 4x 20 mm 3 LSO的TOF分辨率分别为99.7、81.2、66.4 ps-fwhm(无任何校正)、DOI校正和DOI依赖性时间游走校正。从序列中第(2**k)个光子的7个时间戳导出时间游走校正,其中k在[0,6]内。结论:可以从光子时间探测序列估计光子时间游走,并且可以有利地与DOI评估相结合以提高TOF分辨率。
PETALO read-out: A novel approach for data acquisition systems in PET applications
PETALO(a Positron Emission Tof Apparatus based on Liquid XenOn)是一种基于液体氙的正电子发射断层成像新方法。PETALO探测器的目的是利用其均匀的响应和连续性来捕获由闪烁产生的光。与其他PET探测器相比,该策略将导致无几何失真行为。为此,选择用于光读出的传感器是SiPM,其提供大面积、高增益和非常低的噪声。为了利用PETALO探测器的独特特性,读出架构必须设计为满足以下规格:与探测器相关的电子设备(前端和读出本身)必须在探测器尺寸方面完全可扩展。读出方案必须与探测器的非分段结构兼容。飞行时间(TOF)的能力必须在扫描器级别得到保证,也就是说,前端和读出电子设备不应降低LIFE时间性能。在这些程序中,引入了一种新的读出概念,它与PETALO等完全连续的介质探测器兼容。结果表明,该系统是可行的,与快速压缩技术的引入,以进一步降低数据带宽的要求。
A Proof-of-principle for Time-Of-Flight Positron Emission Tomography Imaging
飞行时间(TOF)是一项在全球范围内用于正电子发射断层成像(PET)成像的重要技术。全世界用于TOF-PET的基于闪烁体的成像系统非常昂贵。多间隙电阻板室(MRPC)是一种易于制造、价格低廉、具有良好位置和时间分辨率的气体探测器。它们可以用作昂贵的制冷剂的合适替代品。为了TOF-PET的唯一目的,已经制造了一对18 cm $\times$ 18 cm、5间隙、玻璃基MRPC模块。我们的主要目的是确定这些制造的MRPC的源(Na-22)的位置的变化。在本文件中,将详细介绍实验结果。
A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals
本文提出了一种新的闪烁体探测器命中时间和命中位置重建方法。该方法基于检测器信号与存储在针对闪烁点的一组明确定义的位置配准的同步模型信号库中的结果的比较。命中位置被重建为对应于来自库的与测量信号最相似的信号的命中位置。相互作用的时间被确定为所测量的信号与库中最相似的信号之间的相对时间。测量信号和模型信号的相似度被定义为在多维测量空间中表示测量信号和模型信号的点之间的距离。该方法的新颖性还在于所提出的模型信号同步的方式,使得能够直接确定从湮灭点到检测器的湮灭量子的飞行时间(TOF)之间的差异。使用通过J-PET探测器的双带原型和作为湮灭伽马量子源的$^{22}$ Na钠同位素获得的实验数据来验证所介绍的方法。探测器由尺寸为5 mm x 19 mm x 300 mm的塑料闪烁体带制成,在两侧光学连接到光电倍增管,利用所介绍的方法,建立了空间分辨率约为1.3 cm($σ$),飞行时间分辨率约为125 ps($σ$)的空间分辨率和飞行时间分辨率。
Rethinking Timing Residuals: Advancing PET Detectors with Explicit TOF Corrections
Institute of Imaging and Computer Vision (LfB), RWTH Aachen University(成像与计算机视觉研究所(LfB),亚琛工业大学);Department of Physics of Molecular Imaging Systems (PMI), Institute for Experimental Molecular Imaging, RWTH Aachen University(分子成像系统物理系(PMI),实验分子成像研究所,亚琛工业大学);Institute of High Energy Physics (HEPHY), Austrian Academy of Sciences(高能物理研究所(HEPHY),奥地利科学院);Hyperion Hybrid Imaging Systems GmbH(Hyperion混合成像系统有限公司)
Light-Based Fast Timing in Bulk CsPbBr3 Crystals for TOF-PET and Proton Range Verification
University of California at Davis (UCD)(加州大学戴维斯分校);I3N-Physics Department, University of Aveiro(阿威罗大学I3N物理系);Actinia, Inc(Actinia公司);Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室);Institut de Fı́sica d’Altes Energies - Barcelona Institute of Science and Technology(高能物理研究所-巴塞罗那科学技术学院)
Investigating the Timing Behavior of Compton Scattering in BGO for Time-of-Flight PET
Seoul National University(首尔大学);University of California, Davis(加州大学戴维斯分校);Fondazione Bruno Kessler(布鲁诺·凯斯勒基金会);Brightonix Imaging Inc.(Brightonix成像公司)
Study on Timing Performance of a Readout Circuit for SiPM
近年来,SiPM光电器件在基于飞行时间的正电子发射断层成像(TOF-PET)领域引起了广泛关注。利用它们构造具有良好符合时间分辨率(CTR)的PET探测器一直是研究的热点之一。本文设计了一种基于共基极电流放大器结构的SiPM读出前置放大器,并在前置放大器的基础上引入了零极点(PZ)补偿网络,研究了影响PET探测器时序性能的主要因素。通过实验测量,我们发现CTR与放大器带宽、SiPM偏置电压、比较器阈值以及PZ网络参数有很大关系。测试装置有两个检测器,一个带有与Hamamatsu SiPM(S12642-0404)耦合的LYSO晶体(3 mm 3 mm 10 mm),另一个带有与PMT-R9800耦合的LaBr 3。通过对读出电路的优化设计,得到了两个探测器之间的CTR为266 ps的半高宽。测试结果为下一步读出ASIC芯片的设计提供了指导。
108 ps coincidence time resolution through optimized scintillators, photodetectors, readout electronics, and DOI-based timing correction in orthogonally stacked detector configurations
Central Research Laboratory, Hamamatsu Photonics K. K.(滨松光子株式会社中央研究实验室)
Computing support for advanced medical data analysis and imaging
National Centre for Nuclear Research(国家核研究中心);Institute of Physics, Jagiellonian University(雅盖隆大学物理研究所);Faculty of Chemistry, Jagiellonian University(雅盖隆大学化学学院)
Development of a Cherenkov-Based Time-of-Flight Detector Using Silicon Photomultipliers
Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Bari(意大利国家核物理研究所巴里分部);CERN, European Organization for Nuclear Research(欧洲核子研究组织(CERN));Dipartimento di Fisica dell’Università e del Politecnico di Bari(巴里大学与理工大学物理系)