arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2602.20139physics.ins-detastro-ph.IMhep-ex
收藏

基于切连科夫效应的时差探测器开发

Development of a Cherenkov-Based Time-of-Flight Detector Using Silicon Photomultipliers

Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Bari(意大利国家核物理研究所巴里分部);CERN, European Organization for Nuclear Research(欧洲核子研究组织(CERN));Dipartimento di Fisica dell’Università e del Politecnico di Bari(巴里大学与理工大学物理系)
Liliana Congedo, Giuseppe De Robertis, Antonio Di Mauro, Mario Giliberti, Francesco Licciulli, Antonio Liguori, Rocco Liotino, Leonarda Lorusso, Mario Nicola Ma… 展开作者

Liliana Congedo, Giuseppe De Robertis, Antonio Di Mauro, Mario Giliberti, Francesco Licciulli, Antonio Liguori, Rocco Liotino, Leonarda Lorusso, Mario Nicola Mazziotta, Eugenio Nappi, Nicola Nicassio, Giuliana Panzarini, Roberta Pillera, Giacomo Volpe

AI总结:

本文开发了基于高折射率固态切连科夫辐射体的高精度时差探测器,利用硅光电倍增管实现高时间分辨率,通过优化材料和几何结构,实验验证了优于33.2 ps的时间分辨能力和100%的电荷粒子探测效率。

摘要:

本工作旨在开发基于高折射率固态切连科夫辐射体的高精度时差(TOF)装置,利用硅光电倍增管(SiPM)进行读出。切连科夫光是即时的,因此适合达到时差系统固有时间限制。通过使用薄而高折射率的辐射体,粒子超过切连科夫阈值时可产生几乎即时的信号。为实现最终的时间分辨率,我们进行了辐射体材料和几何结构的严格优化,以及光学耦合到SiPM传感器的效率优化。限制时间分辨率的关键因素通过全面的蒙特卡洛模拟进行表征,并随后通过实验束流测试数据验证。我们组装了小型原型,配备了不同型号的Hamamatsu SiPM阵列传感器,其pitch范围从1.3到3 mm,耦合了不同窗口材料,如熔融石英和MgF2,具有不同厚度值。原型在CERN-PS T10束流线上成功测试。数据通过基于Petiroc 2A或Radioroc 2的前端和读出电子设备,连接到picoTDC以测量电荷和时间。通过比较两个SiPM阵列的时间测量,我们能够测量出全系统水平上优于33.2 ps的时间分辨率,电荷粒子探测效率为100%。我们的结果展示了预期的电荷粒子探测效率和时间分辨率的性能基准,并突显了所开发的基于切连科夫的TOF探测器在下一代粒子识别系统中的潜力。

英文摘要:

The aim of this work is to develop high precision Time-of-Flight (TOF) devices based on high refractive index solid Cherenkov radiators read out by silicon photomultipliers (SiPMs). Cherenkov light is prompt and therefore ideal for reaching the intrinsic timing limits of TOF systems. By utilizing a thin, high-refractive-index radiator a nearly instantaneous signal is generated by particles exceeding the Cherenkov threshold. In order to achieve the ultimate time resolution, we carried out a rigorous optimization of the radiator material and geometry, alongside the efficiency of the optical coupling to the SiPM sensors. The key factors limiting the time resolution were characterized by comprehensive Monte Carlo simulations, subsequently validated against experimental beam test data. We assembled small-scale prototypes instrumented with various Hamamatsu SiPM arrays sensors with pitches ranging from 1.3 to 3 mm coupled with various window materials, such as fused silica and MgF2, featuring various thickness values. The prototypes were successfully tested in beam test campaigns at the CERN-PS T10 beam line. The data were collected with a complete chain of front-end and readout electronics based on either the Petiroc 2A or the Radioroc 2 interfaced to a picoTDC to measure charges and times. By comparing the time measurements with two SiPM arrays we were able to measure a time resolution better than 33.2 ps at the full system level with a charged particle detection efficiency of 100%. Our results demonstrate the expected performance benchmarks for the charged particle detection efficiency and time resolution and highlight the potential of the developed Cherenkov-based TOF detectors for next-generation particle identification systems.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑