Performance of a C4F8O Gas Radiator Ring Imaging Cherenkov Detector Using Multi-anode Photomultiplier Tubes
M. Artuso, C. Boulahouache, S. Blusk, J. Butt, O. Dorjkhaidav, N. Menaa, R. Mountain, H. Muramatsu, R. Nandakumar, K. Randrianarivony, R. Sia, T. Skwarnicki, S.… 展开作者
M. Artuso, C. Boulahouache, S. Blusk, J. Butt, O. Dorjkhaidav, N. Menaa, R. Mountain, H. Muramatsu, R. Nandakumar, K. Randrianarivony, R. Sia, T. Skwarnicki, S. Stone, J. C. Wang, K. Zhang
备注:
28 pages, 23 figures, submitted to Nuclear Instruments and Methods
We report on test results of a novel ring imaging Cherenkov (RICH) detection system consisting of a 3 meter long gaseous C4F8O radiator, a focusing mirror, and a photon detector array based on Hamamatsu multi-anode photomultiplier tubes. This system was developed to identify charged particles in the momentum range from 3-70 GeV/c for the BTeV experiment.
Characterization of the Hamamatsu H12700A-03 and R12699-03 multi-anode photomultiplier tubes
H12700是Hamamatsu生产的新型64通道52 $\times$ 52 mm $^2$方形多阳极光电倍增管(MaPMT)。其特性使该器件适用于高能物理应用,例如环形成像切伦科夫(RICH)探测器。Hamamatsu为H12700管提供了一个嵌入式插座,将阳极连接到输出引脚,并包括一个有源分压器。第二个设备版本R12699也可用,与前者不同的是没有插座。本文描述了一个完整的表征这两种模式,从标准的操作参数(单光子光谱、平均增益、阳极均匀性和暗电流值),详细研究相邻像素之间的串扰效应,并考虑临界环境条件下的行为,例如在高达100高斯的静态磁场存在下,在不同的操作温度下和长时间暴露于强光后。
Characterisation and calibration of a scintillating fibre detector with > 4000 multi-anode photomultiplier channels
在美因茨的Kaos光谱仪中,运行着一个高分辨率的高能粒子坐标探测器。它由直径为4000个< 1mm and is read out by >多阳极光电倍增管通道的增强纤维组成。它是世界上最先进的磁谱仪焦平面探测器之一。为了校正由不同的增益和不同的光学透射率引起的检测效率的变化,已经开发了全自动离线校准程序。该过程包括将放射性同位素源定位在探测器平面旁边以及自动采集和分析探测器信号。可以通过低程度的人工交互来校准和校准每个单独的光纤通道。
Response of a Li-glass/multi-anode photomultiplier detector to $α$-particles from $^{241}$Am
测量了位置敏感锂玻璃闪烁体探测器对来自准直$^{241}$ Am源的$α$粒子的响应。闪烁光由8 X 8像素多阳极光电倍增管读出,并且对于扫描上的每个位置记录每个像素的信号幅度。像素信号强烈地依赖于位置,并且通常几个像素将记录高于给定阈值的信号(命中)。研究了该阈值对命中多重性的影响,以优化检测器的单次命中效率。
Development of a Cherenkov-Based Time-of-Flight Detector Using Silicon Photomultipliers
Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Bari(意大利国家核物理研究所巴里分部);CERN, European Organization for Nuclear Research(欧洲核子研究组织(CERN));Dipartimento di Fisica dell’Università e del Politecnico di Bari(巴里大学与理工大学物理系)
Efficient and precise Cherenkov-based charged particle timing using SiPMs
Istituto Nazionale di Fisica Nucleare, Sezione di Bari(意大利国家核物理研究所巴里分部);CERN, the European Organization for Nuclear Research(欧洲核子研究中心);Dipartimento di Fisica “M. Merlin” dell’Università e del Politecnico di Bari(巴里大学与理工大学M. Merlin物理学系)
Design, simulation and performance of the resistive-anode PICOSEC Micromegas detector
European Organization for Nuclear Research (CERN)(欧洲核子研究组织);Ruđer Bošković Institute(鲁杰尔博什科维奇研究所);University of Zagreb, Faculty of Electrical Engineering and Computing(萨格勒布大学电气工程和计算学院);Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);Stony Brook University(石溪大学);NCSR Demokritos(德谟克利特国家科学研究中心);Laboratório de Instrumentação e Física Experimental de Partículas(粒子物理实验与仪器实验室);Helsinki Institute of Physics, University of Helsinki(赫尔辛基大学赫尔辛基物理研究所);Jefferson Lab(杰斐逊国家加速器设施);University of Science and Technology of China(中国科学技术大学);Helmholtz-Institut für Strahlen- und Kernphysik, University of Bonn(波恩大学赫尔姆霍茨射线与核物理研究所);Physikalisches Institut, University of Bonn(波恩大学物理研究所);CEA-LIST(法国原子能和替代能源委员会列表研究所);Center for Interdisciplinary Research and Innovation (CIRI-AUTH)(跨学科研究与创新中心);National Technical University of Athens(雅典国立技术大学)
Beam test studies for a SiPM-based RICH detector prototype for the future ALICE~3 experiment
Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Bari(意大利国家核物理研究所巴里分部);Dipartimento di Fisica dell’Università e del Politecnico di Bari(巴里大学与理工大学物理系);CERN, the European Organization for Nuclear Research(欧洲核子研究中心);Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México(墨西哥国立自治大学核科学研究所)
Localised response retrieval from Hamamatsu H9500 for a coded aperture neutron-gamma imaging system based on an organic pixelated plastic scintillator (EJ-299-34)
LHCb RICH Upgrade: an overview of the photon detector and electronics system
LHCb实验是欧洲核子研究中心LHC上运行的四个大型探测器之一,主要致力于CP破坏测量和在美丽和魅力强子的罕见衰变中寻找新物理。来自两个环形图像切伦科夫(RICH-1和RICH-2)探测器的数据对于识别宽动量范围内的粒子至关重要。从2019年起,计划进行14 TeV的碰撞,亮度达到$2\cdot10^{33}$ cm $^{-2}$ s $^{-1}$,束团间距为25 ns,目标是每年收集5 fb $^{-1}$的数据。为了避免在如此高的速率(40 MHz)下PID性能的退化,必须升级RICH检测器。新的光电探测器(多阳极光电倍增管,MaPMT)已被选定,并将使用一个8通道芯片,命名为MAPIO,旨在维持光子计数率高达40兆赫,同时尽量减少功耗和串扰读出。128位数字寄存器允许选择阈值和衰减值,并提供有用的测试和调试功能。光电传感器和电子设备被安排在基本单元中,其第一个原型已于2014年秋季在带电粒子束中进行了测试。概述的CNOO功能和读出电子。