Studies of Proximity Focusing RICH with an aerogel radiator using Flat-panel multi-anode PMTs (Hamamatsu H8500)
T. Matsumoto, S. Korpar, I. Adachi, S. Fratina, T. Iijima, R. Ishibashi, H. Kawai, P. Krizan, S. Ogawa, R. Pestotnik, S. Saitoh, T. Seki, T. Sumiyoshi, K. Suzuk… 展开作者
T. Matsumoto, S. Korpar, I. Adachi, S. Fratina, T. Iijima, R. Ishibashi, H. Kawai, P. Krizan, S. Ogawa, R. Pestotnik, S. Saitoh, T. Seki, T. Sumiyoshi, K. Suzuki, T. Tabata, Y. Uchida, Y. Unno
备注:
19 pages, 15 figures. Submitted to Nucl.Instrum.Meth. A
A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for an upgrade of the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4 x 4 array of 64-channel flat-panel multi-anode PMTs (Hamamatsu H8500) with a large effective area. The aerogel samples were made with a new technique to obtain a higher transmission length at a high refractive index (n=1.05). Multi-channel PMTs are read-out with analog memory chips. The detector was tested at the KEK-PS pi2 beam line in November, 2002. To evaluate systematically the performance of the detector, tests were carried out with various aerogel samples using pion beams with momenta between 0.5 GeV/c and 4 GeV/c. The typical angular resolution was around 14 mrad, and the average number of detected photoelectrons was around 6. We expect that pions and kaons can be separated at a 4 sigma level at 4 GeV/c.
Silicon Photo-Multipliers (SiPMs) are semiconductor-based photo-detectors with performances similar to the traditional Photo-Multiplier Tubes (PMTs). An increasing number of experiments dedicated to particle detection in colliders, accelerators, astrophysics, neutrino and rare-event physics involving scintillators are using SiPMs as photodetectors. They are gradually substituting PMTs in many applications, especially where low voltages are required and high magnetic field is present. Hamamatsu Photonics K.K., one of leading producers of photo-detectors, in the last year introduced the S14160 s…
Current and future neutrino and direct detection dark matter experiments hope to take advantage of improving technologies in photon detection. Many of these detectors are large, monolithic optical detectors that use relatively low-cost, large-area, and efficient photomultiplier tubes (PMTs). A candidate PMT for future experiments is a newly developed prototype Hamamatsu PMT, the R5912-MOD. In this paper we describe measurements made of the single photoelectron time and charge response of the R5912-MOD, as well as detail some direct comparisons to similar PMTs. Additionally, a 1D scan of the ph…
Hamamatsu R5900-00-M64 and R7600-00-M64 photomultiplier tubes will be used with wavelength--shifting optical fibres to read out scintillator strips in the MINOS near detector. We report on measurements of the gain, efficiency, linearity, crosstalk, and dark noise of 232 of these PMTs, of which 219 met MINOS requirements.
ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line to search for a LSND-like sterile neutrino signal. The detector employs 360 photomultiplier tubes, Hamamatsu model R5912-MOD, suitable for cryogenic applications. A total of 400 PMTs were procured from Hamamatsu and tested at room temperature to evaluate the performance of the devices and their compliance to detect the liquid argon scintillation light in the T600 detector. Furthermore 60 units were…
The Hamamatsu R11410 and R8520 photomultiplier tubes (PMTs) are designed for applications in dark matter detectors using liquid xenon, featuring excellent sensitivity to VUV light and stable operability at cryogenic temperatures. For eleven R11410 and seven R8520 PMTs, we measured the relative photo-detection sensitivity at 470nm as a function of the position of the incident light on the photocathode. Considering 80% of the photocathode surfaces, the observed non-uniformity values are in the ranges of (5-10)% and (25-30)% for the R11410 and R8520 models, respectively. We found that the non-uni…
The VERITAS gamma-ray telescope array has been operating since 2007 and has been equipped with Hamamatsu R10560-100-20 PMTs since 2012. A decision to continue operations into the mid 2020s was taken in 2019 so the question of whether the PMTs would need replacing became important and a study was initiated. We present results from scanning two groups of 20 Hamamatsu R10560-100-20 PMTs with an LED flasher. One group comprised five PMTs from each of the four VERITAS telescopes and the other was made up of 20 PMTs of the same type, and date of manufacture, that had never been used. We measured thr…
The Hamamatsu R5912-02Mod photomultiplier tube (PMT) will be used in the DUNE dual-phase module, a 10-kton fiducial volume liquid-argon time-projection chamber, which is one of the four projected far-detector modules of the DUNE long-baseline neutrino experiment. In the DUNE dual-phase module, the liquid argon places high pressure on the photo-detectors located at the bottom of the 14-m cryostat. Four Hamamatsu R5912-02Mod PMTs were tested at 4-bar absolute pressure and cryogenic temperature (in liquid nitrogen) for the first time. No mechanical or electrical damage is reported, validating the…
We report on test results of a novel ring imaging Cherenkov (RICH) detection system consisting of a 3 meter long gaseous C4F8O radiator, a focusing mirror, and a photon detector array based on Hamamatsu multi-anode photomultiplier tubes. This system was developed to identify charged particles in the momentum range from 3-70 GeV/c for the BTeV experiment.
A ring imaging Cherenkov counter, to be read out by four 100-channel PMTs, is a key element of the BRAHMS experiment. We report here the most recent results obtained tested at the BNL AGS using several radiator gases, including the heavy fluorocarbon C4F10. Ring radii were measured for different particles (pions, muons, and electrons) for momenta ranging from 2 to 12 GeV/c employing pure C4F10 as radiator.
We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of $6\times6\times20{\rm mm}^3$ which corresponds to the anode pixels of H8500. One of the system is based on commercial ASIC chips in order to readout every anode. The others are based on resistive charge divider network between anodes to reduce readout channels. In both systems, each pixel (6mm) was clearly resolved by flood field irradiation of $^{137}$Cs. We als…
The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24\,m short baseline at J-PARC. The JSNS$^{2}$ inner detector is filled with 17 tons of gadolinium-loaded liquid scintillator (LS) and both the intermediate $γ$-catcher and the optically separated outer veto are filled with un-loaded LS. Optical photons from scintillation are observed by 120 Photomultiplier Tubes (PMTs). A total of 130 PMTs for the JSNS2 experiment were both donated by other experiments and purchased from Hamamatsu. Donated PMTs were pu…
JUNO is a 20-kton liquid scintillator detector aiming to determine the neutrino mass ordering, precisely measure the oscillation parameters, detect the astrophysical neutrinos and search for exotic physics. It is designed to reach an energy resolution of 3% at 1 MeV with the highest ever PMT coverage, using two types of 20 inch phototubes: MCP-PMT from NNVT and dynode-PMT from Hamamatsu. In this article, the gain and charge response of the MCP and dynode PMTs are investigated with the study of JUNO Central Detector prototype. The linearity of the MCP-PMT charge output is measured too to check …
Currently the standard light sensors for imaging atmospheric Cherenkov telescopes are the classical photo multiplier tubes that are using bialkali photo cathodes. About eight years ago we initiated an improvement program with the Photo Multiplier Tube (PMT) manufacturers Hamamatsu (Japan), Electron Tubes Enterprises (England) and Photonis (France) for the needs of imaging atmospheric Cherenkov telescopes. As a result, after about 40 years of stagnation of the peak Quantum Efficiency (QE) on the level of 25-27%, new PMTs appeared with a peak QE of 35%. These have got the name super-bialkali. Th…
New Cryogenic Avalanche Detector (CRAD) with ultimate sensitivity, that will be able to detect one primary electron released in the cryogenic liquid, is under development in the Laboratory of Cosmology and Particle Physics of the Novosibirsk State University jointly with the Budker Institute of Nuclear Physics. The CRAD will use two sets of cryogenic PMTs in order to get trigger signal either from primary scintillations in liquid Ar or from secondary scintillations in high field gap above the liquid. Two types of cryogenic PMTs produced by Hamamatsu Photonics were tested and the results are pr…
Ton-scale liquid xenon detectors operated in two-phase mode are proposed and being constructed recently to explore the favored parameter space for the Weakly Interacting Massive Particles (WIMPs) dark matter. To achieve a better light collection eff ciency while limiting the number of electronics channels compared to the previous generation detectors, large-size photomultiplier tubes (PMTs) such as the 3-inch-diameter R11410 from Hamamatsu are suggested to replace the 1-inch-square R8520 PMTs. In a two-phase xenon dark matter detector, two PMT arrays on the top and bottom are usually used. In …
This paper describes the electronics of NEXT-White (NEW) detector PMT plane, a high pressure xenon TPC with electroluminescent amplification (HPXe-EL) currently operating at the Laboratorio Subterraáneo de Canfranc (LSC) in Huesca, Spain. In NEXT-White the energy of the event is measured by a plane of photomultipliers (PMTs) located behind a transparent cathode. The PMTs are Hamamatsu R11410-10 chosen due to their low radioactivity. The electronics have been designed and implemented to fulfill strict requirements: an overall energy resolution below 1% and a radiopurity budget of 20 mBq unit-1 …
The hemispherical 10" photomultiplier tube (PMT) R7081 from Hamamatsu Photonics K.K. (HPK) is used in various experiments in particle and astroparticle physics. We describe the test and calibration of 474 PMTs for the reactor antineutrino experiment Double Chooz. The unique test setup at Max-Planck-Institut für Kernphysik Heidelberg (MPIK) allows one to calibrate 30 PMTs simultaneously and to characterize the single photo electron response, transit time spread, linear behaviour and saturation effects, photon detection efficiency and high voltage calibration.
Future large water Cherenkov and scintillator detectors have been proposed for measurements of long baseline neutrino oscillations, proton decay, supernova and solar neutrinos. To ensure cost-effectiveness and optimize scientific reach, one of the critical requirements for such detectors are large-area, high performance photomultiplier tubes (PMTs). One candidate for such a device is the Hamamatsu R11780, a 12" PMT that is available in both standard and high quantum efficiency versions. Measurements of the single photoelectron response characteristics, relative efficiencies of the standard and…
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. The characterization is performed durin…
Optimization of the light detection system of the ICARUS detector
INAF-OACT(国家天体物理研究所光学天文台);INFN, Sezione di Catania(意大利国家核物理研究院卡塔尼亚分部);Università degli Studi di Catania(卡塔尼亚大学);INFN, Sezione di Pavia(意大利国家核物理研究院帕维亚分部)
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the two MCP-PMTs combined is better than 10~ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial depe…
The Large High-Altitude Air Shower Observatory (LHAASO) is being built at Haizi Mountain, Sichuan province of China at an altitude of 4410 meters. One of its main goals is to survey the northern sky for very-high-energy gamma ray sources via its ground-based water Cherenkov detector array (WCDA). 900 8-inch photomultiplier tubes (PMTs) CR365-02-1 from Beijing Hamamatsu Photon Techniques INC. (BHP) are installed in the WCDA, collecting Cherenkov photons produced by air shower particles crossing water. The design of the PMT base with a high dynamic range for CR365-02-1, the PMT batch test system…
The properties of large volume cylindrical 3.5 x 8 inches (89 mm x 203 mm) LaBr3:Ce scintillation detectors coupled to the Hamamatsu R10233-100SEL photo-multiplier tube were investigated. These crystals are among the largest ones ever produced and still need to be fully characterized to determine how these detectors can be utilized and in which applications. We tested the detectors using monochromatic gamma-ray sources and in-beam reactions producing gamma rays up to 22.6 MeV; we acquired PMT signal pulses and calculated detector energy resolution and response linearity as a function of gamma-…
We report the results of a characterization study of several types of cryogenic photomultipliers manufactured by Hamamatsu Photonics and intended for operation in liquid Ar conditions, namely: compact 2-inch R6041-506MOD tubes, 3-inch R11065-10 and R11065-MOD tubes for operation in liquid Ar and 3-inch R11410-20 tubes originally designed for operation in liquid Xe. These types of PMT are proposed for installation into the future two-phase cryogenic avalanche detector that is developed in the Laboratory of Cosmology and Particle Physics of the Novosibirsk State University jointly with the Budke…
Ultra-high-energy ($>$ 100 TeV) gamma-ray detection benefits from the use of muon detectors (MDs) thanks to their capability of suppressing the cosmic-ray background. More than 1100 8-inch photomultiplier tubes (PMTs), CR365-02-2 from Beijing Hamamatsu Photon Techniques INC. (BHP), will be deployed for the LHAASO-MD experiment. In this paper, the design of the photomultiplier base for CR365-02-2 is presented. Signals are extracted from two outputs: the anode and the 7th dynode. This design ensures a high dynamic range, from single photoelectron (SPE, peak-to-valley ratio $>$ 2), up to bunches …
Characterization of the 20-inch Photomultiplier Tubes for RENE Detector
Chonnam National University(全南国立大学);Dongshin University(东新大学);Gwangju Institute of Science and Technology(光州科学技术院);Jeonbuk National University(全北国立大学);Kyung Hee University(庆熙大学);Kyungpook National University(庆北国立大学);Sejong University(世宗大学);Seoul National University(首尔大学);Soongsil University(崇实大学);Sungkyunkwan University(成均馆大学)
A prototype of DIRC-like Time-of-Flight detector (DTOF), including a pico-second time measurement electronics, is developed and tested preliminarily. The basic structure of DTOF is composed of a fused silica radiator connected to fast micro-channel plate PMTs (MCP-PMT), and readout by a dedicated FPGA (Field Programmable Gate Array) based front-end electronics. The full electronics chain consists of a programmable differential amplifier, a dual-threshold differential discriminator, and a timestamp Time-to-Digital convertor. By splitting a MCP-PMT output signal into two identical electronics ch…
The Large High-Altitude Air Shower Observatory (LHAASO) is being built at Haizi mountain, Sichuan, China at an altitude of 4410 m. One of its main goals is to survey the northern sky for very-high-energy (above 100 GeV) gamma ray sources via its ground-based Water Cherenkov Detector Array (WCDA). WCDA is 78000 $m^2$ in dimension and consists of 3120 water detector cells divided into 3 water ponds. A hemispherical 8-inch photomultiplier tube (PMT) CR365-02-1 from Beijing Hamamatsu Photon Techniques INC. (BHP) is installed at the bottom-center of each cell of the first water pond to collect Cher…
We have developed particle detectors based on fused silica (quartz) Cherenkov radiators read out with micro-channel plate photomultipliers (MCP-PMTs) or silicon photomultipliers (SiPMs) for high precision timing (Sigma(t) about 10-15 ps). One application is to measure the times of small angle protons from exclusive reactions, e.g. p + p - p + H + p, at the Large Hadron Collider, LHC. They may also be used to measure directional particle fluxes close to external or stored beams. The detectors have small areas (square cm), but need to be active very close (a few mm) to the intense LHC beam, and …
The Hamamatsu R11410-21 photomultiplier tube is the photodetector of choice for the XENON1T dual-phase time projection chamber. The device has been optimized for a very low intrinsic radioactivity, a high quantum efficiency and a high sensitivity to single photon detection. A total of 248 tubes are currently operated in XENON1T, selected out of 321 tested units. In this article the procedures implemented to evaluate the large number of tubes prior to their installation in XENON1T are described. The parameter distributions for all tested tubes are shown, with an emphasis on those selected for X…
Development of a Cherenkov-Based Time-of-Flight Detector Using Silicon Photomultipliers
Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Bari(意大利国家核物理研究所巴里分部);CERN, European Organization for Nuclear Research(欧洲核子研究组织(CERN));Dipartimento di Fisica dell’Università e del Politecnico di Bari(巴里大学与理工大学物理系)