arXivDaily arXiv每日学术速递 周一至周五更新
今晚才能更新了~~大家休息下再来吧
arXiv 1908.08869physics.ins-dethep-exnucl-ex
收藏

Studies of helium poisoning of a Hamamatsu R5900-00-M16 photomultiplier

Rustem Ospanov, Michael Kordosky, Karol Lang, Jing Liu, Thomas Osiecki, Marek Proga, Patricia Vahle

英文摘要:

We report results from studies of the helium poisoning of a 16-anode photomultiplier tube R5900-00-M16 manufactured by Hamamatsu Photonics. A tube was immersed in pure helium for a period of about four months and was periodically monitored using a digital oscilloscope. Our results are based on the analysis of waveforms triggered by the dark noise pulses. Collected data yield evidence of after-pulses due to helium contamination of the tube. The probability of after-pulsing increased linearly with the exposure time to helium but the phototube suffered only a small drop in gain, indicating generally strong resilience to helium poisoning.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑