大面积光电倍增管中的电荷重构

Charge reconstruction in large-area photomultipliers

M. Grassi, M. Montuschi, M. Baldoncini, F. Mantovani, B. Ricci, G. Andronico, V. Antonelli, M. Bellato, E. Bernieri, A. Brigatti, R. Brugnera, A. Budano, M. Bus… 展开作者

M. Grassi, M. Montuschi, M. Baldoncini, F. Mantovani, B. Ricci, G. Andronico, V. Antonelli, M. Bellato, E. Bernieri, A. Brigatti, R. Brugnera, A. Budano, M. Buscemi, S. Bussino, R. Caruso, D. Chiesa, D. Corti, F. Dal Corso, X. F. Ding, S. Dusini, A. Fabbri, G. Fiorentini, R. Ford, A. Formozov, G. Galet, A. Garfagnini, M. Giammarchi, A. Giaz, A. Insolia, R. Isocrate, I. Lippi, F. Longhitano, D. Lo Presti, P. Lombardi, F. Marini, S. M. Mari, C. Martellini, E. Meroni, M. Mezzetto, L. Miramonti, S. Monforte, M. Nastasi, F. Ortica, A. Paoloni, S. Parmeggiano, D. Pedretti, N. Pelliccia, R. Pompilio, E. Previtali, G. Ranucci, A. C. Re, A. Romani, P. Saggese, G. Salamanna, F. H. Sawy, G. Settanta, M. Sisti, C. Sirignano, M. Spinetti, L. Stanco, V. Strati, G. Verde, L. Votano

摘要:

大面积光电倍增管(PMT)可以有效地仪器液体闪烁(LS)中微子探测器,其中大的目标质量是关键,以补偿中微子的极其难以捉摸的性质。根据探测器的光输出,来自相同中微子相互作用的几个闪烁光子可能在几十/几百纳秒内击中单个PMT,导致几个光电子(PE)在PMT阳极处堆积。在这种情况下,由每个PE生成的信号与其他PE纠缠,并且精确的PMT电荷重建变得具有挑战性。该手稿描述了一种实验方法,能够解决的PMT电荷重建的情况下,大PE堆积,提供了一个无偏的电荷估计在千分之一的水平高达15检测到的PE。该方法是基于一个信号滤波技术(维纳滤波器),抑制由于PMT和读出电子的噪声,并基于傅立叶反卷积能够最大限度地减少信号失真的影响-如过冲。模拟PMT波形的分析表明,对重构电荷值和真实电荷值之间的关系建模的线性回归的斜率从$0.769 \pm 0.001$(没有去卷积)提高到$0.989 \pm 0.001$(具有去卷积),其中单一斜率意味着完美重构。电荷重构算法的C++实现可在http://www.fe.infn.it/CRA在线获得。

英文摘要:

Large-area PhotoMultiplier Tubes (PMT) allow to efficiently instrument Liquid Scintillator (LS) neutrino detectors, where large target masses are pivotal to compensate for neutrinos' extremely elusive nature. Depending on the detector light yield, several scintillation photons stemming from the same neutrino interaction are likely to hit a single PMT in a few tens/hundreds of nanoseconds, resulting in several photoelectrons (PEs) to pile-up at the PMT anode. In such scenario, the signal generated by each PE is entangled to the others, and an accurate PMT charge reconstruction becomes challenging. This manuscript describes an experimental method able to address the PMT charge reconstruction in the case of large PE pile-up, providing an unbiased charge estimator at the permille level up to 15 detected PEs. The method is based on a signal filtering technique (Wiener filter) which suppresses the noise due to both PMT and readout electronics, and on a Fourier-based deconvolution able to minimize the influence of signal distortions ---such as an overshoot. The analysis of simulated PMT waveforms shows that the slope of a linear regression modeling the relation between reconstructed and true charge values improves from $0.769 \pm 0.001$ (without deconvolution) to $0.989 \pm 0.001$ (with deconvolution), where unitary slope implies perfect reconstruction. A C++ implementation of the charge reconstruction algorithm is available online at http://www.fe.infn.it/CRA .

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑