Efficient and precise Cherenkov-based charged particle timing using SiPMs
Istituto Nazionale di Fisica Nucleare, Sezione di Bari(意大利国家核物理研究所巴里分部);CERN, the European Organization for Nuclear Research(欧洲核子研究中心);Dipartimento di Fisica “M. Merlin” dell’Università e del Politecnico di Bari(巴里大学与理工大学M. Merlin物理学系)
M. N. Mazziotta, A. Di Mauro, M. Giliberti, A. Liguori, L. Lorusso, E. Nappi, N. Nicassio, G. Panzarini, R. Pillera, G. Volpe
备注:
4 pages, 4 figures, Proceeding of "The 12th International Workshop on Ring Imaging Cherenkov Detectors (RICH 2025)" - September 15-19, 2025 in Mainz (Germany), Submitted to NIM A
Dedicated R&D efforts are currently underway to couple a thin Cherenkov radiator to Silicon Photomultiplier (SiPM) arrays for precise charged particle Time-of-Flight (ToF) measurements. The prompt nature of Cherenkov radiation makes it an ideal candidate for achieving ultimate timing performance in a ToF detector. Using a thin radiator with a high refractive index, such as fused silica, enables the generation of a fast signal from charged particles that exceed the Cherenkov threshold. A crucial requirement for approaching the target time resolution is the optimization of both the radiator material and thickness, as well as the optical coupling to the SiPM arrays. In this work, we present the main factors that affect the time resolution and the expected performance achieved through a detailed Monte Carlo simulation and the comparison with beam test results.
SiPM and front-end electronics development for Cherenkov light detection
意大利核物理研究所参与了切伦科夫望远镜阵列实验SiPM相机演示器的开发,像素大小为6 $\times$ 6 mm $^2$。这款相机拥有大约2000个电子通道,既轻巧又紧凑。在此框架内,正在进行一项研发计划,用于开发适用于切伦科夫光探测的SiPM(所谓的NUV SiPM)。布鲁诺·凯斯勒基金会(FBK)已经生产了不同的光电传感器,具有不同的微单元尺寸和填充因子,不同的几何布置。与此同时,INFN正在开发基于波形采样技术的前端电子设备,该技术针对新型NUV SiPM进行了优化。测量了1个$\times$ 1 mm $^2$、3个$\times$ 3 mm $^2$和6个$\times$ 6 mm $^2$ NUV SiPM耦合到前端电子器件
Evaluation of the optical cross talk level in the SiPMs adopted in ASTRI SST-2M Cherenkov Camera using EASIROC front-end electronics
ASTRI(Astrofisica con Specchi a Tecnologia Replicante Italiana)是意大利教育、大学和研究部的旗舰项目,其主要目标是设计和建造切伦科夫望远镜阵列的小型望远镜原型。样机名为应科院SST-2 M,采用Schwarzschild-Couder配置的宽视场双镜光学系统,探索电磁波谱的VHE范围。焦平面上的相机基于硅光电倍增器探测器,这是探测天文切伦科夫光的创新解决方案。这篇文章报告了一些初步的结果之间的SiPM像素应科院SST-2 M相机预见的光学串扰水平的评估。
Position sensitive SiPM detector for Cherenkov applications
已经构建并测试了具有5.6 x 5.6 cm 2检测面积的位置敏感光电检测器的原型,其具有64个Hamamatsu MPPC(S10931- 100 P),每个MPPC具有3 x 3 mm 2有效面积。光电传感器以8 × 8阵列排列,顶部有一个方形反射镜光导。该模块目前由内部开发的主板读出,但也计划采用针对SiPM读出优化的现有ASIC芯片。这样的设备是一个候选人将用于光子探测的PANDA DIRC探测器。
Measurements of efficiency, timing and response to irradiation for direct detection of charged particles with SiPMs
Museo Storico della Fisica e Centro Studi Enrico Fermi(恩里科·费米物理历史博物馆与研究中心);University of Bologna(博洛尼亚大学);Istituto Nazionale di Fisica Nucleare(意大利国家核物理研究所);Politecnico di Torino(都灵理工大学);Fondazione Bruno Kessler(布鲁诺·凯斯勒基金会);Laboratori Nazionali di Frascati(弗拉斯卡蒂国家实验室)
Application of large area SiPMs for the readout of a plastic scintillator based timing detector
在这项研究中,八个6 mm x 6 mm面积的SiPM阵列耦合到长塑料闪烁体计数器的末端,该计数器在CERN PS暴露于2.5 GeV/c μ子束。研究了尺寸为150 cm x 6 cm x 1 cm和120 cm x 11 cm x 2.5 cm的棒的定时特性。基于新型低输入阻抗电流传输器的8通道SiPM阳极读出ASIC(MUSIC R1)被用来独立地读出和放大SiPM,并在最后对信号求和。根据这些结果,展望了在时间分辨率低于100 ps的大尺度粒子物理探测器中的应用前景。
Beam test studies for a SiPM-based RICH detector prototype for the future ALICE~3 experiment
Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Bari(意大利国家核物理研究所巴里分部);Dipartimento di Fisica dell’Università e del Politecnico di Bari(巴里大学与理工大学物理系);CERN, the European Organization for Nuclear Research(欧洲核子研究中心);Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México(墨西哥国立自治大学核科学研究所)
PySiPMGUI: A Universal Python-Based Software for Photodetector I-V Quality Assurance: From Underground Dark Matter Searches to Astroparticle Cherenkov Cameras
Homi Bhabha National Institute(霍米·巴巴国立研究所);Saha Institute of Nuclear Physics(萨哈核物理研究所)
Cherenkov and scintillation light separation in BGO and BSO crystals coupled to SiPMs for dual-readout electromagnetic calorimetry at future colliders
Università degli Studi di Napoli Federico II(那不勒斯费德里科二世大学);Istituto Nazionale di Fisica Nucleare, Sezione di Napoli(意大利国家核物理研究所,那不勒斯分部);Università degli Studi di Napoli Parthenope(那不勒斯帕尔特诺佩大学);European Center for the Nuclear Research(欧洲核子研究中心);Istituto Nazionale di Fisica Nucleare, Sezione di Milano-Bicocca(意大利国家核物理研究所,米兰比可卡分部);Dipartimento di Fisica e Geologia, Università degli Studi di Perugia(佩鲁贾大学物理与地质学系);Istituto Nazionale di Fisica Nucleare, Sezione di Perugia(意大利国家核物理研究所,佩鲁贾分部);Scuola Superiore Meridionale(南方高等学院)
Study on Timing Performance of a Readout Circuit for SiPM
近年来,SiPM光电器件在基于飞行时间的正电子发射断层成像(TOF-PET)领域引起了广泛关注。利用它们构造具有良好符合时间分辨率(CTR)的PET探测器一直是研究的热点之一。本文设计了一种基于共基极电流放大器结构的SiPM读出前置放大器,并在前置放大器的基础上引入了零极点(PZ)补偿网络,研究了影响PET探测器时序性能的主要因素。通过实验测量,我们发现CTR与放大器带宽、SiPM偏置电压、比较器阈值以及PZ网络参数有很大关系。测试装置有两个检测器,一个带有与Hamamatsu SiPM(S12642-0404)耦合的LYSO晶体(3 mm 3 mm 10 mm),另一个带有与PMT-R9800耦合的LaBr 3。通过对读出电路的优化设计,得到了两个探测器之间的CTR为266 ps的半高宽。测试结果为下一步读出ASIC芯片的设计提供了指导。
Development of a Cherenkov-Based Time-of-Flight Detector Using Silicon Photomultipliers
Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Bari(意大利国家核物理研究所巴里分部);CERN, European Organization for Nuclear Research(欧洲核子研究组织(CERN));Dipartimento di Fisica dell’Università e del Politecnico di Bari(巴里大学与理工大学物理系)
Characterization of thin optical filters for high purity Cherenkov light readout from scintillating crystals
European Center for Nuclear Research(欧洲核子研究中心);Université Claude Bernard Lyon 1, UMR5306 CNRS ILM(里昂第一大学克洛德·贝尔纳);Université de Strasbourg, UMR7178 CNRS IPHC(斯特拉斯堡大学)
A Unified Analytical Framework for LYSO-SiPM Scintillation Pulse Dynamics