We study the feedback of positive ions in triple and quadruple Gas Electron Multiplier (GEM) detectors. The effects of GEM hole diameter, detector gain, applied voltages, number of GEMs and other parameters on ion feedback are investigated in detail. In particular, it was found that the ion feedback is independent of the gas mixture and the pressure. In the optimized multi-GEM structure, the ion feedback current can be suppressed down to 0.5% of the anode current, at a drift field of 0.1 kV/cm and gain of 10^4. A simple model of ion feedback in multi-GEM structures is suggested. The results obtained are relevant to the performance of time projection chambers and gas photomultipliers.
The first operation of GEM gas gain elements in negative ion gas mixtures is reported. Gains up to several thousand were obtained from single-stage GEMs in carbon disulfide vapor at low pressure, and in mixtures of carbon disulfide with Argon and Helium, some near 1 bar total pressure.
In gaseous tracking detectors with a large gaseous volume multiple layers of Gas Electron Multipliers (GEM) can be used to block positive ions from flowing back into the active volume, which is detrimental to the tracking performance. We report on studies of effective gain, ion backflow (IBF), and energy resolution in quadruple GEM detectors, and on strategies for minimizing IBF by optimizing the operating voltages of the individual GEM layers and the potential differences between different layers.
We report on the progress in the study of cascaded GEM and GEM/MHSP gas avalanche photomultipliers operating at atmospheric pressure, with CsI and bialkali photocathodes. They have single-photon sensitivity, ns time resolution and good localization properties. We summarize operational aspects and results, with the highlight of a high-gain stable gated operation of a visible-light device. Of particular importance are the results of a recent ion-backflow reduction study in different cascaded multipliers, affecting the detector's stability and the photocathode's liftime. We report on the signific…
Gas electron Multipliers (GEM) are a new generation of gaseous avalanche devices in the Micro Patterned Gaseous Detector category. GEMs are widely used in both nuclear and high energy experiments as well as in medical science. Several parameters define the performance of these types of devices under various experimental conditions. This article focuses on the study of effective gain and Ion Back Flow (IBF) in both triple and quadruple GEM detectors. Effective gain and IBF are two of the most important parameters in determining the performance of GEM detectors.
A new approach to suppress ion backflow in multi-GEM structures is suggested. In this approach, the potential difference applied across the gap between two adjacent GEMs is reversed compared to the standard configuration. In such a gap structure, called Electric Gate, a signal transfer from the first to second GEM is presumably provided by the small residual field still existing at small gate voltages and connecting the holes of the two GEMs. On the other hand, ion backflow between the GEMs turned out to be substantially reduced. We also consider another configuration, called Photoelectric Gat…
Time Projection Chamber (TPC) has been chosen as the main tracking system in several high-flux and high repetition rate experiments. These include on-going experiments such as ALICE and future experiments such as PANDA at FAIR and ILC. Different $\mathrm{R}\&\mathrm{D}$ activities were carried out on the adoption of Gas Electron Multiplier (GEM) as the gas amplification stage of the ALICE-TPC upgrade version. The requirement of low ion feedback has been established through these activities. Low ion feedback minimizes distortions due to space charge and maintains the necessary values of detecto…
Gaseous detectors are used in both low energy and high energy physics experiments. The present day gaseous detectors, i.e., the Micro-Pattern gaseous detectors (MPGD) are more efficient and fast. Gas Electron multiplier (GEM) is quite well know among the MPGD members. The MPGDs are also being used in other applications like tomography/imaging, moreover, recently, hybridization of two different kinds of MPGD is another emerging subject of R\&D. Ion feedback is an intrinsic drawback of the gaseous detectors. However, it is not a big issue where the event rate is not very high, or the drift volum…
Gated wires are widely used in Time Projection Chamber (TPC) to avoid ion back-flow (IBF) in the drift volume. The anode wires can provide stable gain at high voltage with a long lifetime. However, switching on and off the gated grid (GG) leads to a dead time and also limit the readout efficiency of the TPC. Gas Electron Multiplier (GEM) foil provides a possibility of continuous readout for TPC, which can suppress IBF efficiently while keeping stable gain. A prototype chamber including two layers of GEM foils and anode wires has been built to combine both advantages from GEM and anode wire. Us…
In this work, a fast method of vertex reconstructing for incident ions in GEM detectors was proposed. As inspired by the Time Projection Chamber (TPC), the time information of the consecutive signal samples from Front End Electronics (FEE) was employed. To demonstrate the method, an experiment involving a 2D-readout THGEM detector with an APV-25 FEE was taken. With one experiment dependent parameter in the analysis, the proposed method led to a spatial resolution of 0.45 mm, compared with the same number of 9.10 mm from the traditional center of gravity method.
We show that physics of multi-GEM structures is rather complex, regarding the number of phenomena affecting detector performance. The high-pressure operation in noble gases and the ion feedback are considered in more detail. It is proposed that the dominant avalanche mechanism in He and Ne, at high pressures, is the associative ionization. Ion feedback effects related to the dependence on gas, pressure and gain and to possible avalanche extension outside the GEM holes are discussed.
Gas Electron Multipliers have undergone a very consistent development since their invention in 1997. Their production procedures have been tuned in such a way that nowadays it is possible to produce foils with areas of the order of the square meter that can operate at a reasonable gain, uniform over large areas and with a good stability in what concerns electrical discharges. For the third run of LHC, they will be included in the CMS and ALICE experiments after significant upgrades of the detectors, confirming that these structures are suitable for very large experiments. In the special case o…
A systematic study is performed to measure the ion backflow fraction of the GEM detectors. The effects of different voltage configurations and Ar/CO_2 gas mixtures, in ratios of 70:30, 80:20 and 90:10, on positive ion fraction are investigated in detail. Moreover, a comparative study is performed between single and quadruple GEM detectors.The ion current with detector effective gain is measured with various field configurations and with three proportions of gas mixtures. The ion backflow fraction for the GEM is substantially reduced with the lower drift field. A minimum ion backflow fraction o…
We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%), Ar(70%)-C2H6(30%) and CF4). Detection efficiency of 99%, and spatial resolution of 79 $μ$m in the pad-row direction and 313 $μ$m in the drift direction were achieved. The test results show that the GEM-TPC meets the requirements for high energy heavy ion collision experiments. The configuration and performance of the GEM-TPC are described.
A MicroCAT (Micro Compteur A Trous) structure which is used for avalanche charge multiplication in gas filled radiation detectors has been optimised with respect to maximum electron transparency and minimum ion feedback. We report on the charge transfer behaviour and the achievable gas gain of this device. A three-dimensional electron and ion transfer simulation is compared to results derived from electric current measurements. Similarly, we present studies of the charge transfer behaviour of a GEM (Gas Electron Multiplier) by current measurements and simulations. Finally, we investigate the c…
The performance of triple-GEM detectors in He+N2 gas mixtures is studied in the range of 1-10 atm. The results obtained are relevant in the field of minimization of ionic space-charge effect in the TPC and neutron detection.
We report on measurements of charge transfer in GEM structures in high magnetic fields. These were performed in the framework of the R&D work for a Time Projection Chamber at a future Linear Collider. A small test chamber has been installed into the aperture of a superconducting magnet with the GEM structures mounted perpendicular to the B field direction. The charge transfer is derived from the electrical currents monitored during irradiation with an ${}^{55}$Fe source. No severe loss of primary ionisation charge is observed, but an improved ion feedback suppression is achieved for high magne…
This document contains the pre-design of the beam diagnostics components Tracking Detectors for the Super-FRS. A GEM-TPC detector has been suggested as suitable tracking detector for the ion/fragment beams produced at the in-flight separator Super-FRS under construction at the FAIR facility. The detector concept combines two widely used approaches in gas filled detectors, the Time Projection Chamber (TPC) and the Gas Electron Multiplication (GEM). Three detector generations (prototypes) have been tested in 2011, 2012 and 2014 with relativistic ion beams at GSI. Due to the high-resolution achro…
Results obtained with a triple GEM detector operated in pure CF4 with and without a reflective CsI photocathode are presented. The detector operates in a stable mode at gains up to 10^4. A deviation from exponential growth starts to develop when the total charge exceeds ~ 4 10^6 e leading to gain saturation when the total charge is ~ 2 10^7 e and making the structure relatively robust against discharges. No aging effects are observed in the GEM foils after a total accumulated charge of ~ 10 mC/cm^2 at the anode. The ion back-flow current to the reflective photocathode is comparable to the elec…
We have operated a Medipix2 CMOS readout chip, with amplifying, shaping and charge discriminating front-end electronics integrated on the pixel-level, as a highly segmented direct charge collecting anode in a three-stage gas electron multiplier (Triple-GEM) to detect the ionization from $^{55}$Fe X-rays and electrons from $^{106}$Ru. The device allows to perform moderate energy spectroscopy measurements (20 % FWHM at 5.9 keV $X$-rays) using only digital readout and two discriminator thresholds. Being a truly 2D-detector, it allows to observe individual clusters of minimum ionizing charged part…
A fundamental limit to the application of Time Projection Chambers (TPCs) in high-rate experiments is the accumulation of slowly drifting ions in the active gas volume, which compromises the homogeneity of the drift field and hence the detector resolution. Conventionally, this problem is overcome by the use of ion-gating structures. This method, however, introduces large dead times and restricts trigger rates to a few hundred per second. The ion gate can be eliminated from the setup by the use of Gas Electron Multiplier (GEM) foils for gas amplification, which intrinsically suppress the backfl…
We present recent results on the operation of gas-avalanche detectors comprising a cascade of gas electron multipliers (GEMs) and Micro-Hole and Strip Plates (MHSPs) multiplier operated in reversed-bias (R-MHSP) mode. The operation mechanism of the R-MHSP is explained and its potential contribution to ion-backflow (IBF) reduction is demonstrated. IBF values of 4E-3 were obtained in cascaded R-MHSP and GEM multipliers at gains of about 1E+4, though at the expense of reduced effective gain in the first R- MHSP multiplier in the cascade.
A prototype detector is being developed which combines the functions of a Time Projection Chamber for charged particle tracking and a Cherenkov detector for particle identification. The TPC consists of a 10x10x10 cm3 drift volume where the charge is drifted to a 10x10 cm2 triple GEM detector. The charge is measured on a readout plane consisting of 2x10 mm2 chevron pads which provide a spatial resolution ~ 100 microns per point in the chevron direction along with dE/dx information. The Cherenkov portion of the detector consists of a second 10x10 cm2 triple GEM with a photosensitive CsI photocat…
A Time Projection Chamber (TPC) is a powerful detector for 3-dimensional tracking and particle identification for ultra-high multiplicity events. It is the central tracking device of many experiments, e.g. the ALICE experiment at CERN. The necessity of a switching electrostatic gate, which prevents ions produced in the amplification region o MWPCs from entering the drift volume, however, restricts its application to trigger rates of the order of 1 kHz. Charge amplification by Gas Electron Multiplier (GEM) foils instead of proportional wires offers an intrinsic suppression of the ion backflow, …
Multiple-GEM detectors are considered to be good candidates for tracking devices in experiments with high hadronic background. We present the results of the triple-GEM detectors beam test in a high intensity pion beam. The detectors had an optimized two-dimensional readout with minimized strip capacitance. Such optimization permitted the starting point of the efficiency plateau down to a gain of 5000. The probability of GEM discharges induced by heavily ionizing particles has been measured as a function of gain: at a gain of 20000 it amounts to 10^(-11) per incident particle. Such a value will…
Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are captured in a single 2 um thick Boron-10 converter cathode and secondary Helium and Lithium ions are produced with a combined energy of 2.8 MeV. These ions have sufficient energy to form straight tracks of several mm length. With a time resolving 2-dimensional readout of 400 um pitch in both directions, based on APV25 chips, the ions are tracked and their respe…
Gas Electron Multiplier (GEM)-based detectors using a layer of 10B as a neutron converter is becoming popular for thermal neutron detection. A common strategy to simulate this kind of detector is based on two frameworks: Geant4 and Garfield++. The first one provides the simulation of the nuclear interaction between neutrons and the 10B layer, while the second allows the simulation of the interaction of the reaction products with the detector gas leading to the ionization and excitation of the gas molecules. Given the high ionizing power of these nuclear reaction products, a full simulation is …
We report the status of R&D on large triple-GEM detectors for a forward tracker (FT) in an experiment at a future Electron Ion Collider (EIC) that will improve our understanding of QCD. We have designed a detector prototype specifically targeted for the EIC-FT, which has a trapezoidal shape with 30.1 degrees opening angle. We are investigating different detector assembly techniques and signal readout technologies, but have designed a common GEM foil to minimize NRE cost for foil production. The assembly techniques comprise either a purely mechanical method including foil stretching as pioneere…
We present measurements of drift velocities and mobilities of some innovative negative ion gas mixtures at nearly atmospheric pressure based on SF$_{6}$ as electronegative capture agent and of pure SF$_{6}$ at various pressures, performed with the NITEC detector. NITEC is a Time Projection Chamber with 5 cm drift distance readout by a GEMPix, a triple thin GEMs coupled to a Quad-Timepix chip, directly sensitive to the deposited charge on each of the 55 $\times$ 55 $μ$m$^2$ pixel. Our results contribute to expanding the knowledge on the innovative use of SF$_{6}$ as negative ion gas and extend …
A general solution to the positive ion feedback problem in Hybrid Photon Detectors (HPD), photo multipliers (PM) and other similar detectors was found in the insertion of a permanent electrostatic potential barrier which prevents drift of positive ions from the anode, or the first dynode, towards the photocathode. In this paper we present the method as applied to the Intevac HPD.
A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented. It is a hybrid structure cascaded Gas Electron Multiplier (GEM) with a Micromegas detector. Both Micromegas and GEM have the capability to naturally reduce most of the ions produced in the amplification region. The GEM also acts as the preamplifer device and increases gas gain together with the Micromegas. Feasibility tests of the hybrid detector are performed using an ${}^{55}$Fe X-ray source. The energy resolution is better tha…
A large Time Projection Chamber (TPC) is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019-2020, the LHC will deliver Pb beams colliding at an interaction rate of up to 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. To fully exploit the LHC potential, the TPC readout chambers will be upgraded with Gas Electron Multiplier (GEM) technology. To assure stable behaviour of the upgraded chambers in the harsh LHC environment, a dedicated R&D programme was launched in order …
Imaging Hybrid Photon Detectors (HPD) have been developed for integration in large area Cherenkov detectors for high energy physics and astrophysics. The presented designs - developed particularly for the experiments MAGIC, LHCb and AQUA-RICH - comprise very good imaging properties, protection against positive ion feedback and(or) minimum dead area. The underlying innovations are discussed in some detail.
The properties of thick GEM-like (TGEM) gaseous electron multipliers, operated at 1-740 Torr are presented. They are made of a G-10 plate, perforated with millimeter-scale diameter holes. In single-multiplier elements, effective gains of about 104, 106, and 105 were reached at respective pressures of 1, 10 Torr isobutane and 740 Torr Ar/5%CH4, with pulse rise-times in the few nanosecond scale. The high effective gain at atmospheric pressure was measured with a TGEM coated with a CsI photocathode. The detector was operated in single and cascaded modes. Potential applications in ion and photon d…
The STAR experiment at the Relativistic Heavy Ion Collider RHIC studies the new state of matter produced in relativistic heavy ion collisions and the spin structure of the nucleon in collisions of polarized protons. In order to improve the capabilities for heavy flavor measurements and the reconstruction of charged vector bosons an upgrade of the tracking system both in the central and the forward region is pursued. The challenging environments of high track multiplicity in heavy ion collisions and of high luminosity in polarized proton collisions require the use of new technologies. The propo…
The ALICE (A Large Ion Collider Experiment) experiment at the Large Hadron Collider (LHC) at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC) of ALICE is a tracking detector located in the central region of the experiment. It offers excellent tracking capabilities as well as particle identification. After the second long shutdown (LS2) the LHC will run at substantially higher luminosities. To be able to increase the data acquisition rate by a factor of 100, the ALICE TPC experiment has to replace the Multi-Wire Pr…
We present avalanche gain and associated resolution measurements recorded with a $^4$He:CO$_2$ (70:30) gas mixture and pure SF$_6$, a Negative Ion (NI) gas. SF$_6$ is of particular interest to the directional dark matter detection community, as its low thermal diffusion helps to retain recoil ionization track features over long drift lengths. With the aid of a general form of the reduced first Townsend coefficient (RFTC), multiple GEM-based detector data sets are used to study the high-gain behavior of the $^4$He:CO$_2$ gas mixture. The high-gain data is well described purely in terms of the r…
Thick GEM-like (THGEM) gaseous electron multipliers are made of standard printed-circuit board perforated with sub-millimeter diameter holes, etched at their rims. Effective gas multiplication factors of 100000 and 10000000 and fast pulses in the few nanosecond rise-time scale were reached in single- and cascaded double-THGEM elements, in atmospheric-pressure standard gas mixtures with single photoelectrons. High single-electron detection efficiency is obtained in photon detectors combining THGEMs and semitransparent UV-sensitive CsI photocathodes or reflective ones deposited on the top THGEM …
A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed variations of the gain, of the ion back-flow, and of the pulse height spectra are explained in terms of the effects of the spatial distribution of positive ions and their movement throughout the amplification structure. The intrinsic dynamic character of the processes involved imposes the use of a non-standard simulation tool for the interpretation of the measur…
The major challenge to improve deterministic single ion sources is to control the position and momentum of each ion. Based on the extra information given by the electron created in a photoionization process, the trajectory of the correlated ion can be controlled using a fast real time feedback system. In this paper, we report on a proof-of-principle experiment that demonstrates the performances of this feedback control with individual cesium ions. The produced electron is detected with a time and position sensitive detector, whose information are used to quickly infer the position of the corre…
In CBM Experiment at FAIR, dimuons will be detected by a Muon Chamber (MUCH) consisting of segmented absorbers of varying widths and tracking chambers sandwiched between the absorber-pairs. In this fixed target heavy-ion collision experiment, operating at highest interaction rate of $10~MHz$ for $Au+Au$ collision, after the first MUCH detector station in its inner radial ring will face a particle rate of $1~MHz/cm^2$. To operate at such a high particle density, GEM technology based detectors have been selected for the first two stations of MUCH. We have reported earlier the performance of seve…
One of the potential problems of a Micro-Pattern Gaseous Detector (MPGD)-based Time Projection Chamber (TPC) is the Ion back Flow (IBF): ions generated through the avalanche amplification process flow back to the drift volume of the TPC and disarrange an electric field inside it. Consequently non-negligible degradation of azimuthal spatial resolution is caused due to this IBF. Meanwhile, it is necessary to collect primary ionized electrons to maintain intrinsic performance of the MPGDs. The MPGD based TPC is currently planned to be used as a central tracking detector of the International Large…
The CMS collaboration aims at improving the muon trigger and tracking performance at the HL-LHC by installing new Gas Electron Multiplier (GEM) chambers in the endcaps of the CMS experiment. Construction and commissioning of GEM chambers for the first muon endcap stations is ramping up in several laboratories using common quality control protocols. The SCRIBE framework is a scalable and cross-platform webbased application for the RD51 Scalable Readout System (SRS) that controls data acquisition and analyzes data in near real time. It has been developed mainly to simplify and standardize measur…
The bubble-assisted Liquid Hole-Multiplier (LHM) is a recently-introduced detection concept for noble-liquid time projection chambers. In this "local dual-phase" detection element, a gas bubble is supported underneath a perforated electrode (e.g., Thick Gas Electron Multiplier - THGEM, or Gas Electron Multiplier - GEM). Electrons drifting through the holes induce large electroluminescence signals as they pass into the bubble. In this work we report on recent results of THGEM and GEM electrodes coated with cesium iodide and immersed in liquid xenon, allowing - for the first time - the detection…
A prototype Gas Electron Multiplier (GEM) detector is under construction for medical imaging purposes. A single thick GEM of size 10x10 cm^2 is assembled inside a square shaped air-tight box which is made of Perspex glass. In order to ionize gas inside the drift field two types of voltage supplier circuits were fabricated, and array of 2x4 pads of each size 4x8 mm^2 were utilized for collecting avalanche charges. Preliminary testing results show that the circuit which produces high voltage and low current is better than that of low voltage and high current supplier circuit in terms of x-ray si…
Gas-based time projection chambers (TPCs) have been shown to be highly sensitive X-ray polarimeters having excellent quantum efficiency while at the same time achieving large modulation factors. To observe polarization of the prompt X-ray emission of a Gamma-ray burst (GRB), a large area detector is needed. Diffusion of the electron cloud in a standard TPC could be prohibitive to measuring good modulation when the drift distance is large. Therefore, we propose using a negative ion TPC (NITPC) with Nitromethane (CH3NO2) as the electron capture agent. The diffusion of negative ions is reduced ov…
Optical readout of Gas Electron Multipliers (GEM) provides very interesting performances and has been proposed for different applications in particle physics. In particular, thanks to its good efficiency in the keV energy range, it is being developed for low-energy and rare event studies, such as Dark Matter search. So far, the optical approach exploits the light produced during the avalanche processes in GEM channels. Further luminescence in the gas can be induced by electrons accelerated by a suitable electric field. The CYGNO collaboration studied this process with a combined use of a tripl…
A fast, hydrodynamic numerical model has been developed on the COMSOL Multi-physics platform to simulate the evolution and dynamics of charged particles in gaseous ionization detectors based on the Gaseous Electron Multipliers (GEM). Effects of using two-dimensional (2D), 2D axisymmetric and three-dimensional(3D) models of the detectors have been analyzed to choose the optimum configuration. The chosen model has been used to follow the entire operating regime of single, double and triple GEM detectors, including avalanche and streamer mode operations. The accumulation of space charge, its cont…
The characteristics of triple GEM detectors have been studied systematically by using cosmic ray muons. The minimum ionizing particle (MIP) spectra has been taken for different GEM voltage setting. Efficiency of GEM detector has been measured for cosmic ray. At high rate operation of GEMs the value of the protection resistor influences the gain and the stability. This feature has been investigated varying both the rate and the value of the protection resistor. This measurement has been performed using both X-ray generator and Fe55 source. The ageing and long-term stability of GEM based detecto…
Triple Gas Electron Multiplier (GEM) detectors will be used as a tracking device in the first two stations of CBM MUon CHamber (MUCH), where the maximum particle rate is expected to reach ~1 MHz/cm2 for central Au-Au collisions at 8 AGeV. Therefore, the stable operation of the detector is very important. Discharge probability has been measured of a single mask triple GEM detector at the CERN SPS/H4 beam-line facility with a pion beam of ~150 GeV/c and also in an environment of highly ionizing shower particles. The spark probability as a function of gain has been studied for different particle …
The dynamics of the positive ions created by particle interactions inside argon time projection chambers plays an important role in characterizing the next generation of massive detectors planned for the direct search for dark matter and the study of neutrino properties. We have constructed a 1 L liquid argon chamber (ARION: ARgon ION experiment) with a high voltage pulse generator capable of injecting, in a controlled manner, a sizeable ion current into the drift region. This chamber is capable of reproducing a volume charge similar to that found in large detectors, allowing its effects to be…