Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
P. Moskal, N. Krawczyk, B. C. Hiesmayr, M. Bała, C. Curceanu, E. Czerwiński, K. Dulski, A. Gajos, M. Gorgol, R. Del Grande, B. Jasińska, K. Kacprzak, L. Kapłon,… 展开作者
P. Moskal, N. Krawczyk, B. C. Hiesmayr, M. Bała, C. Curceanu, E. Czerwiński, K. Dulski, A. Gajos, M. Gorgol, R. Del Grande, B. Jasińska, K. Kacprzak, L. Kapłon, D. Kisielewska, K. Klimaszewski, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, J. Raj, Z. Rudy, S. Sharma, M. Silarski, M. Pawlik-Niedźwiecka, L. Raczyński, S. Shivani, R. Y. Shopa, M. Skurzok, W. Wiślicki, B. Zgardzińska
J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on the feasibility of such polarization measurements of photons from the decay of positronium with the J-PET and explore the physical limitations for the resolution of the polarization determination of 511 keV photons via Compton scattering. For scattering angles of about 82 deg (where the best contrast for polarization measurement is theoretically predicted) we find that the single event resolution for the determination of the polarization is about 40 deg (predominantly due to properties of the Compton effect). However, for samples larger than ten thousand events the J-PET is capable of determining relative average polarization of these photons with the precision of about few degrees. The obtained results open new perspectives for studies of various physics phenomena such as quantum entanglement and tests of discrete symmetries in decays of positronium and extend the energy range of polarization measurements by five orders of magnitude beyond the optical wavelength regime.
A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector
High-resolution Time-Of-Flight PET with Depth-Of-Interaction becomes feasible: a proof of principle
在本文中,我们证明了闪烁体表面的适当处理的选择,以及用于原始数据分析的适当光电探测器电子器件和特定算法,允许实现能量、时间和DOI分辨率之间的最佳权衡,从而强烈支持具有所需特征和性能的前列腺TOF-PET探针的可行性,所述探针与MRI兼容。在数量上,这意味着1.5mm x 1.5mm x 10 mm的探测器元件,同时实现约11.5%的能量分辨率、约150 ps的飞行时间分辨率和甚至低于1 mm的DOI分辨率。我们强调,这样的时间分辨率允许显著增加噪声等效计数率,从而提高图像质量和病变检测能力。这些个别值对应于其他小组迄今为止获得的最佳值,但我们同时获得了所有这些值。在我们看来,这一原理证明为具有前所未有的功能和性能的TOF-PET MRI兼容探头的可行性铺平了道路,不仅是前列腺放射性示踪剂成像的创新,而且可能也适用于其他器官。
Light-Based Fast Timing in Bulk CsPbBr3 Crystals for TOF-PET and Proton Range Verification
University of California at Davis (UCD)(加州大学戴维斯分校);I3N-Physics Department, University of Aveiro(阿威罗大学I3N物理系);Actinia, Inc(Actinia公司);Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室);Institut de Fı́sica d’Altes Energies - Barcelona Institute of Science and Technology(高能物理研究所-巴塞罗那科学技术学院)
R&D of cosmic ray detection module with liquid scintillator and wavelength shift fiber
University of South China(南华大学);State Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences(高能物理研究所粒子天体物理国家重点实验室,中国科学院);Tianfu Cosmic Ray Research Center(天府宇宙线研究中心);Institute of High Energy Physics(高能物理研究所);University of Chinese Academy of Sciences(中国科学院大学);State Key Laboratory of Particle Detection and Electronics(粒子探测与电子学国家重点实验室);Sun Yat-sen University(中山大学);North China Electric Power University(华北电力大学);Institute of Frontier and Interdisciplinary Science, Shandong University(山东大学前沿交叉科学高等研究院)