arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2603.12975physics.med-ph
收藏

混合离子束实现碳离子治疗中的同时治疗与实时成像

Mixed Ion Beams Enable Simultaneous Treatment and Real-Time Imaging in Carbon Ion Therapy

GSI Helmholtzzentrum für Schwerionenforschung(GSI亥姆霍兹重离子研究中心);University College London(伦敦大学学院);Centro Nazionale di Adroterapia Oncologica (CNAO)(国家肿瘤质子治疗中心);Technische Universität Darmstadt(达姆施塔特工业大学);University Federico II(那不勒斯费德里科二世大学)
Lennart Volz, Ronja Hetzel, Maximilian Dick, Maria Chiara Martire, Guangru Li, Christoph Schuy, Sali Ballouz, Mikael Simard, Saad Shaikh, Charles-Antoine Collin… 展开作者

Lennart Volz, Ronja Hetzel, Maximilian Dick, Maria Chiara Martire, Guangru Li, Christoph Schuy, Sali Ballouz, Mikael Simard, Saad Shaikh, Charles-Antoine Collins-Fekete, Tim Wagner, Michael Galonska, Andrii Patushenko, Ralph Hollinger, Fabio Maimone, Jens Stadlmann, Lars Bozyk, David Ondreka, Simone Savazzi, Marco Pullia, Marco Durante, Christian Graeff

AI总结:

混合离子束在碳离子治疗中实现同时治疗与实时成像,通过氦离子提供治疗反馈,提升治疗精度和范围监测能力。

摘要:

碳离子治疗是放射治疗中最先进的形式之一,有望提高对耐药癌症的疗效。然而,碳离子布拉格峰的高精度要求需要精确知道患者体内束的范围。我们报告了首次利用混合离子束实现范围监测和门控成像的实验实现,其中碳离子用于治疗肿瘤,同时氦离子被加速至相同速度完全穿过患者并提供治疗反馈。利用GSI同步加速器,加速12C3+和4He1+离子束,利用其几乎相同的电荷-质量比。展示了稳定的提取和可控的氦离子比例,最低可达7%。束流特性表明,氦离子布拉格峰可从碳离子碎片背景中清晰分离,从而实现亚毫米级布拉格峰位移的准确检测。混合束对肺癌样仿真实验显示目标位置检测精度优于0.5毫米。这确立了混合束作为碳离子治疗实时图像引导的强大模式,唯一提供同时治疗交付、范围探测和门控成像。通过克服患者内部的范围不确定性,混合束将使碳离子治疗的精度得到充分利用。

英文摘要:

Carbon ion therapy is one of the most advanced forms of radiotherapy, promising improved efficacy against resistant cancers. However, the high precision offered by the carbon ion Bragg peak requires precise knowledge of the beam range inside the patient. We report the first experimental realization of range monitoring and portal imaging with a mixed ion beam, where carbon ions are treating the tumor while helium ions simultaneously accelerated to the same velocity fully traverse the patient and provide treatment feedback. Using the GSI synchrotron, a beam of 12C3+ and 4He1+ ions is accelerated, exploiting their nearly identical charge-to-mass ratios. Stable extraction with controlled helium fractions down to 7% is demonstrated. Beam characterization reveals that the helium ion Bragg peak can be cleanly separated from the carbon ion fragment background which enables accurate detection of sub-millimeter Bragg peak displacements. Mixed-beam radiographs of a lung-cancer-like phantom offer target position detection to better than 0.5 mm accuracy. This establishes mixed beams as a powerful modality for real-time image guidance in carbon ion therapy, uniquely providing simultaneous treatment delivery, range probing, and portal imaging. By overcoming range uncertainty inside the patient, mixed beams will enable to fully exploit the precision of carbon ion therapy.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑