The secondary neutron fields at the deep tumor therapy terminal at HIRFL (Heavy Ion Research Facility in Lanzhou) were investigated. The distributions of neutron ambient dose equivalent were measured with a FHT762 Wendi-II neutron ambient dose equivalent meter as the 12C ions with energies of 165, 207, 270, and 350 MeV/u bombarded on thick tissue-like targets. The thickness of targets used in experiments is larger than the range of the carbon ions. The neutron spectra and dose equivalent is simulated by using FLUKA code, and the results agree well with the experimental data. The experiment results showed that the neutron dose produced by fragmentation reactions in tissue can be neglected in carbon-ion therapy, even considering their enhanced biological effectiveness. These results are also valuable for radiation protection, especially in the shielding design of high energy heavy ion medical machines.
The neutron dose distributions on observation distances and on observation angles were measured using a Wendi-II neutron dose-meter at the deep tumor therapy terminal at HIRFL (Heavy Ion Research Facility in Lanzhou) as 12C ions with energies from 165 to 350 MeV/u bombarding on thick solid water targets with different thickness according to the ion energies. The experimental results were compared with those calculated by FLUKA code. It is found that the experimental data was in good agreement with the calculated results. The neutron energy spectra were also studied by using the FLUKA code. The…
Purpose: We present a framework for robust automated treatment planning using machine learning, comprising scenario-specific dose prediction and robust dose mimicking. Methods: The scenario dose prediction pipeline is divided into the prediction of nominal dose from input image and the prediction of scenario dose from nominal dose, each using a deep learning model with U-net architecture. By using a specially developed dose-volume histogram-based loss function, the predicted scenario doses are ensured sufficient target coverage despite the possibility of the training data being non-robust. Del…
In this research, we presented the method of inhalation therapy with noble gas micro-doses and results of clinical studies in hospital of Russian Academy of Sciences (RAS). We have designed a device that allows dosed injection of noble gas with a volume of about 2-4 ml with peroxide vapors into the nasal cavity. After testing on the authors of the project and obtaining a positive impact of xenon and krypton, a study was conducted on a group of conditionally healthy volunteers in the amount of 20 people. We have noted a positive effect from 18 people. And also, in this article we briefly descri…
In this work, we propose a Machine Learning model that generates an adjustable 3D dose distribution for external beam radiation therapy for head-and-neck cancer treatments. In contrast to existing Machine Learning methods that provide a single model, we create pairs of models for each organ-at-risk, namely lower-extreme and upper-extreme models. These model pairs for an organ-at-risk propose doses that give lower and higher doses to that organ-at-risk, while also encapsulating the dose trade-off to other organs-at-risk. By weighting and combining the model pairs for all organs-at-risk, we are …
A new strategy for radiation therapy dosimetry planning (RTDP) used to reduce dose estimation errors due to respiratory motion in breast treatment was illustrated and evaluated in this study. On CT data set acquired for breast treatment, six different RTDP tangential techniques were performed: (i) three-dimensional conformal radiotherapy (3DCRT) with physical wedge, (ii) 3DCRT with virtual wedge, (iii) motion management technique (MMT) with physical wedge, (iv) MMT with virtual wedge, (v) 3DCRT with field-in-field, and (vi) intensity-modulated radiation therapy (IMRT) with direct aperture opti…
To accurately verify the dose of intensity-modulated radiation therapy (IMRT), we have used a global optimization method to investigate a new dose-verification algorithm. In practical application of this quality assurance (QA) procedure, verification of the dose using calculated and measured dose distributions involves a subtle problem in the region of high dose gradient. Consideration of systematic errors shows that the large dose differences in high-dose-gradient regions are due to the unexpected shift of measuring devices. We have proposed an optimization algorithm to correct this error, an…
We present a method of directly optimizing on deviations in clinical goal values in radiation therapy treatment planning. Using a new mathematical framework in which metrics derived from the dose-volume histogram are regarded as functionals of an auxiliary random variable, we are able to obtain volume-at-dose and dose-at-volume as infinitely differentiable functions of the dose distribution with easily evaluable function values and gradients. Motivated by the connection to risk measures in finance, which is formalized in this framework, we also derive closed-form formulas for mean-tail-dose an…
Secondary radiation in a radiation therapy environment is considered a cause for post-treatment side effects including secondary carcinogenesis. In a proton-therapy setup, neutrons deliver a considerable extra dose to the patient. Various measurements and calculations of neutron dose suggest a wide range of values for this quantity. This paper provides a comparison between the previously published values and analyzes the Monte Carlo calculated neutron dose from the present work using the neutron cross-section data. The purpose is to provide a range for the convergence of several neutron-absorb…
Fast and accurate dose predictions are one of the bottlenecks in treatment planning for microbeam radiation therapy (MRT). In this paper, we propose a machine learning (ML) model based on a 3D U-Net. Our approach predicts separately the large doses of the narrow high intensity synchrotron microbeams and the lower valley doses between them. For this purpose, a concept of macro peak doses and macro valley doses is introduced, describing the respective doses not on a microscopic level but as macroscopic quantities in larger voxels. The ML model is trained to mimic full Monte Carlo (MC) data. Comp…
Purpose: The presence of respiratory motion during radiation treatment leads to degradation of the expected dose distribution, both for target coverage and healthy-tissue sparing, particularly for techniques like pencil-beam scanning proton therapy which have dynamic delivery systems. While tools exist to estimate this degraded four-dimensional (4D) dose, they typically have one or more deficiencies such as ... Methods: To quickly compute the 4D-dose, the three main tasks of the calculator were run on graphics processing units (GPUs). These tasks were: simulating the delivery of the plan using…
Cone beam CT (CBCT) has been widely used for patient setup in image guided radiation therapy (IGRT). Radiation dose from CBCT scans has become a clinical concern. The purposes of this study are 1) to commission a GPU-based Monte Carlo (MC) dose calculation package gCTD for Varian On-Board Imaging (OBI) system and test the calculation accuracy, and 2) to quantitatively evaluate CBCT dose from the OBI system in typical IGRT scan protocols. We first conducted dose measurements in a water phantom. X-ray source model parameters used in gCTD are obtained through a commissioning process. gCTD accurac…
Radiotherapy of pregnant cancer patients is not common, but when applied accurate assessment of the fetus dose is required, especially since the treatment planning systems are not able and do not allow accurate assessment of out-of-field doses. Proton therapy significantly reduces out-of-field doses, such as dose to the fetus, when compared to the photon radiotherapy techniques and as such could be promising for pregnant cancer patients. Within this study Monte Carlo calculations are performed on the three different computational phantoms representing pregnant women, all in second trimester of…
We demonstrate the application of mixture density networks (MDNs) in the context of automated radiation therapy treatment planning. It is shown that an MDN can produce good predictions of dose distributions as well as reflect uncertain decision making associated with inherently conflicting clinical tradeoffs, in contrast to deterministic methods previously investigated in literature. A two-component Gaussian MDN is trained on a set of treatment plans for postoperative prostate patients with varying extents to which rectum dose sparing was prioritized over target coverage. Examination on a test…
For the in vivo range verification in proton therapy, it has been tried to measure the spatial distribution of the prompt gammas generated by the proton-induced interactions with the close relationship with the proton dose distribution. However, the high energy of the prompt gammas and background gammas are still problematic in measuring the distribution. In this study, we suggested a new method determining the in vivo range by utilizing the time structure of the prompt gammas formed with the rotation of a range modulation wheel (RMW) in the passive scattering proton therapy. To validate the M…
Purpose: To verify dose delivery and quality assurance of volumetric modulated arc therapy (VMAT) for head and neck cancer. Method: The Imaging and Radiation Oncology Core Houston (IROC-H) head and neck phantom with thermo- luminescent dosimeters (TLDs) and films, were imaged with computed tomography scan and the reconstructed image was transferred to pinnacle treatment planning system (TPS). On TPS the planning target volume (PTV), secondary target volume (STV) and organ at risk (OAR) were delineated manually and a treatment plan was made. The dose constraints were determined for the concerne…
Cao et al (2018) published an article on inverse planning based on dose-averaged linear energy transfer (LET). Their claim that the problem can be cast as a linear optimization model relies on an incorrect application of the Charnes-Cooper transformation. In this comment we show that their linear model is simlar to one where dose-averaged LET is multiplied with dose, explaining why their model was nonetheless able to improve the LET distribution.
We give a scenario-based treatment plan optimization formulation that is equivalent to planning with geometric margins if the scenario doses are calculated using the static dose cloud approximation. If the scenario doses are instead calculated more accurately, then our formulation provides a novel robust planning method that overcomes many of the difficulties associated with previous scenario-based robust planning methods. In particular, our method protects only against uncertainties that can occur in practice, it gives a sharp dose fall-off outside high dose regions, and it avoids underdosage…
We study the propagation of nucleons and nuclei in tissue-like media within a Monte Carlo Model for Heavy-ion Therapy (MCHIT) based on the GEANT4 toolkit (version 8.2). The model takes into account fragmentation of projectile nuclei and secondary interactions of produced nuclear fragments. Model predictions are validated with available experimental data obtained for water and PMMA phantoms irradiated by monoenergetic carbon-ion beams. The MCHIT model describes well (1) the depth-dose distributions in water and PMMA, (2) the doses measured for fragments of certain charge, (3) the distributions …
Beam modelling of Hitachi PROBEAT proton therapy system for a GPU-based Fast Monte Carlo dose engine
University of Nebraska Omaha(内布拉斯加大学奥马哈分校);Rice University(莱斯大学);The University of Texas MD Anderson Cancer(德克萨斯大学安德森癌症中心);Mevion Medical System(美维医疗系统);Emory University(埃默里大学)
Two full rotating gantry with different nozzles (Multipurpose nozzle with MLC, Scanning Dedicated nozzle) with conventional cyclotron system is installed and under commissioning for various proton treatment options at Samsung Medical Center in Korea. The purpose of this study is to investigate neutron dose equivalent per therapeutic dose, H/D, to x-ray imaging equipment under various treatment conditions with monte carlo simulation. At first, we investigated H/D with the various modifications of the beam line devices (Scattering, Scanning, Multi-leaf collimator, Aperture, Compensator) at isoce…
In this study, two proton beam delivery designs, passive scattering proton therapy (PSPT) and pencil beam scanning (PBS), were quantitatively compared in terms of dosimetric indices. The GATE Monte Carlo code was used to simulate the proton beam system; and the developed simulation engines were benchmarked with respect to the experimental measurements. A water phantom was used to simulate system energy parameters using a set of depth-dose data in the energy range of 120-235 MeV. To compare the performance of PSPT against PBS, multiple dosimetric parameters including FWHM, peak position, range,…
In intensity-modulated radiation therapy, optimal intensity distributions of incoming beams are decomposed into linear combinations of leaf openings of a multileaf collimator (segments). In order to avoid inefficient dose delivery, the decomposition should satisfy a number of dosimetric constraints due to suboptimal dose characteristics of small segments. However, exact decomposition with dosimetric constraints is only in limited cases possible. The present work introduces new heuristic segmentation algorithms for the following optimization problem: Find a segmentation of an approximated matri…
We compared the treatment planning performance of RapidArc (RA) vs. CyberKnife (CK) for spinal stereotactic body radiation therapy (SBRT). Ten patients with spinal lesions who had been treated with CK were re-planned with RA, which consisted of two complete arcs. Computed tomography (CT) and volumetric dose data of CK, generated using the Multiplan (Accuray) treatment planning system (TPS) and the Ray-Trace algorithm, were imported to Varian Eclipse TPS in Dicom format, and the data were compared with the RA plan using analytical anisotropic algorithm (AAA) dose calculation. The optimized dose…
Cancer is a primary cause of morbidity and mortality worldwide. The radiotherapy plays a more and more important role in cancer treatment. In the radiotherapy, the dose distribution maps in patient need to be calculated and evaluated for the purpose of killing tumor and protecting healthy tissue. Monte Carlo (MC) radiation transport calculation is able to account for all aspects of radiological physics within 3D heterogeneous media such as the human body and generate the dose distribution maps accurately. However, an MC calculation for doses in radiotherapy usually takes a great mass of time t…
Diffusing Alpha-emitters Radiation Therapy (DaRT) is a new method for treating solid tumors using alpha particles. Unlike conventional radiotherapy, where the physical models for dose calculations are known and routinely used, for DaRT a new framework, called the Diffusion-Leakage (DL) model, had to be developed. In this work we provide a detailed description of a finite-element numerical scheme for solving the time-dependent DL model equations for cylindrical DaRT sources (``seeds'') of finite diameter and length in two dimensions. Using a fully-implicit scheme and adaptive time step, this ap…
Purpose: To assess the effects of brain movements induced by heartbeat on dose distributions in synchrotron micro- and mini-beam radiaton therapy and to develop a model to help guide decisions and planning for future clinical trials. Methods: The Monte Carlo code PENELOPE was used to simulate the irradiation of a human head phantom with a variety of micro- and mini-beam arrays, with beams narrower than 100mum and above 500mum, respectively, and with radiation fields of 1cmx2cm and 2cmx2cm. The dose in the phantom due to these beams was calculated by superposing the dose profiles obtained for a…
In radiation therapy, mathematical methods have been used for optimizing treatment planning for delivery of sufficient dose to the cancerous cells while keeping the dose to critical surrounding structures minimal. This optimization problem can be modeled using mixed integer programming (MIP) whose solution gives the optimal beam orientation as well as optimal beam intensity. The challenge, however, is the computation time for this large scale MIP. We propose and investigate two novel heuristic approaches to reduce the computation time considerably while attaining high-quality solutions. We int…
Therapeutic protons acting on O18-substituted thymidine increase cytotoxicity in radio-resistant human cancer cells. We consider here the physics behind the irradiation during proton beam therapy and diagnosis using O18-enriched thymine in DNA, with attention to the effect of the presence of thymine-18 on cancer cell death.
Adaptive Radiation Therapy (ART) was developed based on Image-guided Radiation Therapy (IGRT) and it is the trend of photon radiation therapy. To get a better use of Cone Beam CT (CBCT) images for ART, the CBCT system model was established based on Monte Carlo program and validated against the measurement. The BEAMnrc program was adopted to the KV x-ray tube. Both IOURCE-13 and ISOURCE-24 were chosen to simulate the path of beam particles. The measured Percentage Depth Dose (PDD) and lateral dose profiles under 1cm water were compared with the dose calculated by DOSXYZnrc program. The calculat…
The Fast Dose Calculator (FDC), a track repeating algorithm Monte Carlo method was initially developed for proton therapy. The validation for proton therapy has been demonstrated in a previous work. This method can be expanded to ion applications. Our purpose of this paper is to validate the FDC for carbon therapy. We compare the 3D dose distributions and dose-volume-histograms (DVH) for carbon calculated by FDC with a full Monte Carlo method, GEANT 4. 19 patients in total will be discussed, including 3 patients of prostate, 5 of brain, 3 of head and neck, 4 of lung and 4 of spine. We use gamm…
Purpose: To demonstrate the feasibility of fast Monte Carlo (MC) based inverse biological planning for the treatment of head and neck tumors in spot-scanning proton therapy. Methods: Recently, a fast and accurate Graphics Processor Unit (GPU)-based MC simulation of proton transport was developed and used as the dose calculation engine in a GPU-accelerated IMPT optimizer. Besides dose, the dose-averaged linear energy transfer (LETd) can be simultaneously scored, which makes biological dose (BD) optimization possible. To convert from LETd to BD, a linear relation was assumed. Using this novel op…
Background and Objective: Recent experimental studies using ultra-high dose rate radiation therapy (FLASH-RT) have shown improved normal tissue sparing and comparable tumor control compared to conventional dose rate RT. Pencil beam scanning (PBS) proton therapy with superior dosimetry characteristics has begun to draw attention to the delivery of conformal FLASH-RT for preclinical studies. This review aims to provide recent updates on the development of PBS FLASH-RT. Methods: The information summarized in this review article is based on search results in databases such as PubMed and search eng…
Purpose: The purpose of this work was to provide a flexible platform for FLASH research with protons by adapting a former clinical pencil beam scanning gantry to irradiations with ultrahigh dose rates. Methods: PSI Gantry 1 treated patients until December 2018. We optimized the beamline parameters to transport the 250 MeV beam extracted from the PSI COMET accelerator to the treatment room, maximizing the transmission of beam intensity to the sample. We characterized a dose monitor on the gantry to ensure good control of the dose, delivered in spot-scanning mode. We characterized the beam for d…
The purpose of this study was to use various dosimetrical indices to determine the best IMRT modality technique for treating patients with prostate cancer. Ten patients with prostate cancer were included in this study. Intensity modulated radiation therapy plans were designed to include different modalities, including the linac step and shoot, Tomotherapy, RapidArc, and Proton systems. Various dosimetrical indices, like the prescription isodose to target volume (PITV) ratio, conformity index (CI), homogeneity index (HI), target coverage index (TCI), modified dose homogeneity index (MHI), confo…