碳离子治疗中的射程裕度缩减:使用放射性离子束的潜在益处
Range margin reduction in carbon ion therapy: potential benefits of using radioactive ion beams
AI总结:
本研究评估了放射性11C离子束在碳离子治疗中通过降低射程不确定性来缩减安全裕度的潜力,证明其能实现毫米级体内射程监测,并显著改善危及器官的保护效果。
摘要:
使用重离子(特别是12C束)的放射治疗是最先进的癌症治疗形式之一。在靶区具有陡峭的剂量梯度和高生物学效应,使其成为治疗深部和抗放射性肿瘤的理想工具,但同时,它对射程预测中的微小误差也非常敏感。为了减轻这些不确定性并确保肿瘤体积的均匀覆盖,会在肿瘤体积上添加安全裕度,但在照射过程中,这会导致对周围健康组织的不可避免的损伤。为了充分利用尖锐的Bragg峰的优势,人们在为所谓的图像引导放射治疗建立精确的射程验证方法上投入了大量精力。尽管正电子发射断层扫描(PET)已广泛用于12C离子治疗的这一目的,但低计数率、生物洗脱以及活性分布的宽泛形状仍将其精度限制在几毫米内。相反,直接用于治疗的放射性束将产生改善的信号,并与剂量跌落更紧密地匹配,从而有可能实现精确的体内束流射程监测。我们进行了一项治疗计划研究,以评估由放射性11C束治疗所实现的射程不确定性降低对保护肿瘤邻近关键器官的可能影响。我们证明:原则上,11C离子的湮灭图能够反映患者体内剂量分布中甚至毫米级的偏移;与12C计划相比,11C束的治疗计划结果在满足危及器官约束条件方面有显著改善;并且,与12C治疗相比,在射程不确定性降低的11C治疗后,预计对串联和并联关键器官的毒性会更轻。
英文摘要:
Radiotherapy with heavy ions, in particular, 12C beams, is one of the most advanced forms of cancer treatment. Sharp dose gradients and high biological effectiveness in the target region make them an ideal tool to treat deep-seated and radioresistant tumors, however, at the same time, sensitive to small errors in the range prediction. Safety margins are added to the tumor volume to mitigate these uncertainties and ensure its uniform coverage, but during the irradiation they lead to unavoidable damage to the surrounding healthy tissue. To fully exploit the benefits of a sharp Bragg peak, a large effort is put into establishing precise range verification methods for the so-called image-guided radiotherapy. Despite positron emission tomography being widely in use for this purpose in 12C ion therapy, the low count rates, biological washout, and broad shape of the activity distribution still limit its precision to a few millimeters. Instead, radioactive beams used directly for treatment would yield an improved signal and a closer match with the dose fall-off, potentially enabling precise in vivo beam range monitoring. We have performed a treatment planning study to estimate the possible impact of the reduced range uncertainties, enabled by radioactive 11C beams treatments, on sparing critical organs in the tumor proximity. We demonstrate that (i) annihilation maps for 11C ions can in principle reflect even millimeter shifts in dose distributions in the patient, (ii) outcomes of treatment planning with 11C beams are significantly improved in terms of meeting the constraints for the organs at risk compared to 12C plans, and (iii) less severe toxicities for serial and parallel critical organs can be expected following 11C treatment with reduced range uncertainties, compared to 12C treatments.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。