利用多回波 MP2RAGE 序列绘制脂肪-水分离的 R1、R2*和质子密度脂肪分数图

Mapping fat-water separated R1, R2*, and proton density fat fraction with the multi-echo MP2RAGE sequence

McGill University(麦吉尔大学);Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院)

Jorge Campos Pazmiño, Marc-Antoine Fortin, Véronique Fortier, Evan McNabb, Renée-Claude Bider, André van der Kouwe, Ives R. Levesque

AI总结:

该研究利用多回波 MP2RAGE 序列,通过脂肪和水特异性信号计算 R1f、R1w,经脂肪-水分离获取 R2*和 PDFF 图,设计四种协议并经模拟、体模及体内实验验证,实现单次采集同时定量上述指标。

摘要:

目的:开发一种结合多回波磁化准备快速梯度回波(ME-MP2RAGE)序列和脂肪-水分离技术,用于联合测量脂肪和水特异性纵向弛豫率(R1f 和 R1w)、有效横向弛豫率(R2*)和质子密度脂肪分数(PDFF)的技术。理论与方法:通过脂肪特异性和水特异性 MP2RAGE 信号计算 R1f 和 R1w,从应用于第二个 RAGE 块的脂肪-水分离中获得 R2*和 PDFF 图。通过克拉美-罗下界理论进行序列参数优化,设计了四种不同回波数和读出梯度方案组合的协议。通过数值模拟、体模和体内实验对这些协议进行测试和验证。在体模中,将 ME-MP2RAGE 测量结果与反转恢复自旋回波(IR-SE)全局 R1 和 3D 快速低角度激发(3D FLASH)R2*和 PDFF 进行比较。在体内扫描健康志愿者的小腿和颈部。结果:数值模拟表明,使用协议 ME-MP2RAGE IV(10 回波双极)时,弛豫率的平均相对偏差<3%,PDFF 的平均偏差<0.003,定量准确。体模实验表明与 IR-SE 和 3D FLASH 测量结果高度一致。在体内,小腿和颈部的测量结果与文献值一致。结论:我们提出了一种准确的方法,可通过单次采集的 ME-MP2RAGE 序列同时定量 R1f、R1w、R2*和 PDFF。

英文摘要:

Purpose: To develop a technique for joint measurement of fat and water-specific longitudinal relaxation rates (R1f and R1w), effective transverse relaxation rate (R2*), and proton density fat fraction (PDFF) combining the Multi-Echo Magnetization Prepared Two Rapid Acquisition of Gradient Echoes (ME-MP2RAGE) sequence and fat-water separation. Theory and Methods: R1f and R1w were calculated with fat-specific and water-specific MP2RAGE signals. R2* and PDFF maps were obtained from fat-water separation applied to the second RAGE block. Sequence parameters optimization was performed via Cramér-Rao lower bounds theory, and we designed four protocols with different combinations of number of echoes and readout gradient schemes (I: 3 echoes unipolar, II: 6 echoes unipolar, III: 6 echoes bipolar, and IV: 10 echoes bipolar). We tested and validated these protocols with numerical simulations, phantom and in vivo experiments. In phantoms, we compared ME-MP2RAGE measurements with inversion recovery spin-echo (IR-SE) global R1 and 3D Fast Low Angle Shot (3D FLASH) R2* and PDFF. In vivo, we scanned the lower leg and neck of a healthy volunteer. Results: Numerical simulations showed accurate quantification of relaxation rates with mean relative bias < 3% and PDFF with mean bias < 0.003 using protocol ME-MP2RAGE IV (10 echoes bipolar). Phantom experiments showed excellent agreement with IR-SE and 3D FLASH measurements. In vivo, measurements in the lower leg and neck were consistent with literature values. Conclusion: We proposed an accurate method for simultaneous quantification of R1f, R1w, R2*, and PDFF from a single acquisition with the ME-MP2RAGE sequence.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑