SPARCQ:利用相位循环bSSFP信号轮廓的不对称性进行脂肪分数标测的新方法
SPARCQ: A new approach for fat fraction mapping using asymmetries in the phase-cycled bSSFP signal profile
AI总结:
SPARCQ利用相位循环bSSFP信号轮廓的不对称性,通过多隔室字典匹配实现脂肪分数定量,模拟与体模实验验证其准确性,志愿者实验显示良好对比,重复性系数为0.0512。
摘要:
目的:开发SPARCQ(信号轮廓不对称性用于快速隔室定量),一种利用相位循环bSSFP轮廓中的不对称性来量化脂肪分数的新方法。方法:SPARCQ使用相位循环获取bSSFP频率轮廓,在特定重复时间下,这些轮廓在存在脂肪和水时显示不对称性。对于每个体素,通过多隔室字典匹配将测量的信号轮廓分解为模拟轮廓的加权和。每个字典条目代表具有特定离共振频率和弛豫时间比的单隔室bSSFP轮廓。利用字典匹配的结果,提取每个体素不同离共振组分的分数,生成整个图像体积的水和脂肪分数的定量图以及无带状伪影图像。SPARCQ通过模拟、水脂体模实验和健康志愿者膝盖实验进行了验证。实验结果与参考质子密度脂肪分数进行了比较,参考值分别来自1H-MRS(体模)和多回波梯度回波MRI(体模和志愿者)。SPARCQ的可重复性在六次扫描-重扫描实验中进行了评估。结果:模拟显示,对于信噪比大于20的情况,脂肪分数定量准确且稳健。体模实验表明SPARCQ与金标准脂肪分数之间具有良好的一致性。在志愿者中,使用SPARCQ和ME-GRE获得的无带状伪影定量图和水脂分离图像显示了脂肪组织与非脂肪组织之间的预期对比。SPARCQ脂肪分数的重复性系数为0.0512。结论:SPARCQ展示了利用bSSFP轮廓不对称性进行脂肪定量的潜力,可能成为传统脂肪分数定量技术的有前景的替代方案。
英文摘要:
Purpose: To develop SPARCQ (Signal Profile Asymmetries for Rapid Compartment Quantification), a novel approach to quantify fat fraction using asymmetries in the phase-cycled bSSFP profile. Methods: SPARCQ uses phase-cycling to obtain bSSFP frequency profiles, which display asymmetries in the presence of fat and water at certain repetition times. For each voxel, the measured signal profile is decomposed into a weighted sum of simulated profiles via multi-compartment dictionary matching. Each dictionary entry represents a single-compartment bSSFP profile with a specific off-resonance frequency and relaxation time ratio. Using the results of dictionary matching, the fractions of the different off-resonance components are extracted for each voxel, generating quantitative maps of water and fat fraction and banding-artifact-free images for the entire image volume. SPARCQ was validated using simulations, experiments in a water-fat phantom and in knees of healthy volunteers. Experimental results were compared with reference proton density fat fractions obtained with 1H-MRS (phantoms) and with multiecho gradient-echo MRI (phantoms and volunteers). SPARCQ repeatability was evaluated in six scan-rescan experiments. Results: Simulations showed that fat fraction quantification is accurate and robust for signal-to-noise ratios greater than 20. Phantom experiments demonstrated good agreement between SPARCQ and gold standard fat fractions. In volunteers, banding-artifact-free quantitative maps and water-fat-separated images obtained with SPARCQ and ME-GRE demonstrated the expected contrast between fatty and non-fatty tissues. The coefficient of repeatability of SPARCQ fat fraction was 0.0512. Conclusion: SPARCQ demonstrates potential for fat quantification using asymmetries in bSSFP profiles, and may be a promising alternative to conventional fat fraction quantification techniques.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。