arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2604.05707physics.med-phcs.LG
收藏

对呼出呼吸中运动后脂肪氧化挥发性标志物的非靶向分析

Untargeted analysis of volatile markers of post-exercise fat oxidation in exhaled breath

Fraunhofer Institute for Digital Medicine MEVIS, Bremen, Germany(弗劳恩霍夫数字医学研究所 MEVIS,德国不来梅);Department of Sensory Analytics and Technologies, Fraunhofer Institute for Process Engineering and Packaging IVV, Freising, Germany(弗劳恩霍夫过程工程与包装研究所 IVV 感官分析和技术部,德国弗赖辛)

André Homeyer, Júlia Blanka Sziládi, Jan-Philipp Redlich, Jonathan Beauchamp, Y Lan Pham

AI总结:

研究通过非靶向筛查呼出呼吸中的挥发性有机化合物,发现乙酰丙酮是脂肪氧化的关键标志物,证实了其在运动后预测脂肪氧化的能力。

摘要:

呼吸中的乙酰丙酮代表了一种有前景的非侵入性生物标志物,用于监测运动期间的脂肪氧化。然而,其用途受到混杂因素的限制,且显著浓度变化仅在运动后数小时发生,这使得实时评估困难。我们进行了非靶向筛查,寻找可能作为脂肪氧化标志物的挥发性有机化合物(VOCs),并研究了运动期间的呼吸测量是否能预测运动后脂肪氧化的变化。19名参与者完成了两次25分钟的骑行 sessions,间隔5分钟的休息期。使用质子转移反应时间飞行质谱(PTR-TOF-MS)分析运动期间和90分钟恢复期后的VOC排放。血清β-羟基丁酸(BOHB)浓度作为脂肪氧化的参考标志物。在773个相关分析特征中,只有四个信号与BOHB(ρ≥0.82,p=0.0002)有强相关性,均归因于乙酰丙酮或其同位素或碎片。运动结束时的这些信号测量能够准确预测有显著运动后BOHB变化的参与者(F1分数≥0.83,准确率=0.89)。本研究未发现任何新的呼吸基生物标志物,但证实了乙酰丙酮是关键标志物。此外,我们的发现表明,运动期间的呼吸乙酰丙酮测量可能已经能够对运动后脂肪氧化进行基本预测。

英文摘要:

Breath acetone represents a promising non-invasive biomarker for monitoring fat oxidation during exercise. However, its utility is limited by confounding factors, as well as by the fact that significant changes in concentration occur only hours post-exercise, which makes real-time assessment difficult. We performed an untargeted screening for volatile organic compounds (VOCs) that could serve as markers of fat oxidation beyond acetone, and investigated whether breath measurements taken during exercise could predict post-exercise changes in fat oxidation. Nineteen participants completed two 25-min cycling sessions separated by a brief 5-min rest period. VOC emissions were analysed using proton-transfer-reaction time-of-flight mass spectrometry (PTR-TOF-MS) during exercise and after a 90-min recovery period. Blood $β$-hydroxybutyrate (BOHB) concentrations served as the reference marker for fat oxidation. Among 773 relevant analytical features detected in the PTR-TOF-MS measurements, only four signals exhibited strong correlations with BOHB ($ρ$ $\geq$ 0.82, p = 0.0002)-all attributable to acetone or its isotopologues or fragments. End-of-exercise measurements of these signals enabled accurate prediction of participants with substantial post-exercise BOHB changes (F1 score $\geq$ 0.83, accuracy = 0.89). Our study did not reveal any novel breath-based biomarkers of fat oxidation, but it confirmed acetone as the key marker. Moreover, our findings suggest that breath acetone measurements during exercise may already enable basic predictions of post-exercise fat oxidation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑