arXiv 2402.05366physics.med-ph
收藏

基于模型的联合估计 $T_{1}$、$R_{2}^{*}$ 和 $B_{0}$ 场图的重建方法:使用单次反转恢复多回波径向FLASH

Model-Based Reconstruction for Joint Estimation of $T_{1}$, $R_{2}^{*}$ and $B_{0}$ Field Maps Using Single-Shot Inversion-Recovery Multi-Echo Radial FLASH

Xiaoqing Wang, Nick Scholand, Zhengguo Tan, Daniel Mackner, Vitali Telezki, Moritz Blumenthal, Philip Schaten, Martin Uecker

AI总结:

提出一种基于模型的非线性重建方法,结合单次反转恢复多回波径向FLASH,在四秒内联合估计水特异性T1、R2*、B0场和脂肪分数图,并通过体模和体内实验验证了准确性与精度。

摘要:

目的:开发一种基于模型的非线性重建方法,用于使用单次反转恢复(IR)多回波径向FLASH序列同时进行水特异性 $T_{1}$、$R_{2}^{*}$、$B_{0}$ 场和/或脂肪分数(FF)成像。方法:所提出的基于模型的重建直接从使用单次IR多回波径向FLASH序列(跨回波使用blip梯度)获得的 $k$-空间数据中联合估计水特异性 $T_{1}$、$R_{2}^{*}$、$B_{0}$ 场和/或FF图,以及一组线圈灵敏度。利用多个定量图上的联合稀疏约束来提高精度。在数值和NIST体模上以及3 T下的人脑和肝脏的体内研究中进行了验证。结果:数值体模研究展示了脂肪信号在 $T_{1}$ 估计中的影响,并确认了所提出方法对所有参数图具有良好的定量准确性。NIST体模结果与笛卡尔参考相比,确认了良好的定量 $T_{1}$ 和 $R_{2}^{*}$ 准确性。除了多个参数图的良好定量准确性和精度外,体内研究表明利用所提出的联合估计改善了图像细节。所提出的方法可以在四秒内实现脑(0.81 × 0.81 × 5 mm$^{3}$)和肝脏(1.6 × 1.6 × 6 mm$^{3}$)成像的同时水特异性 $T_{1}$、$R_{2}^{*}$、$B_{0}$ 场和/或FF映射。结论:所提出的基于模型的非线性重建与单次IR多回波径向FLASH采集相结合,能够在四秒内联合估计准确的水特异性 $T_{1}$、$R_{2}^{*}$、$B_{0}$ 场和/或FF图。本工作对特定临床应用具有潜在价值。

英文摘要:

Purpose: To develop a model-based nonlinear reconstruction for simultaneous water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or fat fraction (FF) mapping using single-shot inversion-recovery (IR) multi-echo radial FLASH. Methods: The proposed model-based reconstruction jointly estimates water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or FF maps, as well as a set of coil sensitivities directly from $k$-space obtained with a single-shot IR multi-echo radial FLASH sequence using blip gradients across echoes. Joint sparsity constraints are exploited on multiple quantitative maps to improve precision. Validations are performed on numerical and NIST phantoms and with in vivo studies of the human brain and liver at 3 T. Results: Numerical phantom studies demonstrate the effects of fat signals in $T_{1}$ estimation and confirm good quantitative accuracy of the proposed method for all parameter maps. NIST phantom results confirm good quantitative $T_{1}$ and $R_{2}^{*}$ accuracy in comparison to Cartesian references. Apart from good quantitative accuracy and precision for multiple parameter maps, in vivo studies show improved image details utilizing the proposed joint estimation. The proposed method can achieve simultaneous water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or FF mapping for brain (0.81 $\times$ 0.81 $\times$ 5 mm$^{3}$) and liver (1.6 $\times$ 1.6 $\times$ 6 mm$^{3}$) imaging within four seconds. Conclusion: The proposed model-based nonlinear reconstruction, in combination with a single-shot IR multi-echo radial FLASH acquisition, enables joint estimation of accurate water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or FF maps within four seconds. The present work is of potential value for specific clinical applications.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑