基于导频音的全心自由运行多回波GRE运动分辨脂肪分数成像

Motion-resolved fat-fraction mapping with whole-heart free-running multiecho gre and pilot tone

Adèle L. C. Mackowiak, Christopher W. Roy, Jérôme Yerly, Mariana B. L. Falcão, Mario Bacher, Peter Speier, Davide Piccini, Matthias Stuber, Jessica A. M. Bastiaansen

AI总结:

本研究提出一种基于导频音导航的自由运行多回波GRE序列,实现6分钟内全心心脏和呼吸运动分辨的脂肪分数定量成像,并在1.5T志愿者实验中验证了其可行性与准确性。

摘要:

目的:开发自由运行的多回波GRE序列,用于心脏和呼吸运动分辨的全心脂肪分数定量。方法:将针对水脂分离和定量优化的多回波读出集成到非ECG触发、自由呼吸的3D径向GRE采集序列中。使用导频音导航提取心脏和呼吸运动状态。基于XD-GRASP对各回波进行图像重建后,采用基于图割的最大似然拟合算法生成脂肪分数、水分数、R2star和B0图,以及脂肪和水图像。该采集、重建和后处理框架在1.5T下对10名健康志愿者进行了测试,并与自由呼吸ECG触发的5回波采集进行了比较。结果:该采集在体内成功验证,在所有采集的回波中,在呼吸和心脏两个维度均实现了运动补偿。导频音导航提供的呼吸和心脏信号与基于第一回波MR数据的自门控信号提取结果具有良好的一致性(r分别为0.954和0.783)。该框架实现了跨心动周期的心包脂肪成像和定量,揭示了志愿者在收缩期表观脂肪分数(FF)的下降。3D运动分辨脂肪分数图与参考ECG触发测量结果具有良好的相关性,且NTE=4和NTE=8回波测量结果存在显著差异(胸部脂肪P<0.0001,心包脂肪P<0.01)。结论:1.5T下的志愿者实验证明了在6分钟扫描时间内,以2mm³各向同性分辨率进行全心自由运行脂肪分数成像技术用于心脏MRI的可行性。

英文摘要:

PURPOSE To develop free-running multi-echo GRE for cardiac- and respiratory-motion-resolved whole-heart fat fraction quantification. METHODS Multi-echo readouts optimized for water-fat separation and quantification were integrated within a non-ECG-triggered free-breathing 3D radial GRE acquisition. Pilot Tone navigation was used to extract cardiac and respiratory motion states. Following a XD-GRASP based image reconstruction of the separate echoes, fat fraction, water fraction, R2star and B0 maps, as well as fat and water images, were generated with a maximum likelihood fitting algorithm using graph cuts. The acquisition, reconstruction and post-processing framework was tested in 10 healthy volunteers at 1.5T and compared to a free-breathing ECG-triggered 5-echo acquisition. RESULTS The acquisition was successfully validated in vivo, with motion compensation achieved over all collected echoes, in both respiratory and cardiac dimensions. Pilot Tone navigation provided respiratory and cardiac signals in good agreement (r=0.954 and r=0.783, respectively) with self-gating signal extraction based on the MR data of the first echo. The framework enabled pericardial fat imaging and quantification across the cardiac cycle, revealing a decrease in apparent FF at systole across volunteers. 3D motion-resolved fat fraction maps showed good correlation with reference ECG-triggered measurements, as well as significant difference in measurements performed with NTE = 4 and NTE = 8 echoes (P < 0.0001 in chest fat and P < 0.01 in pericardial fat). CONCLUSION Volunteer experiments at 1.5T demonstrated the feasibility of a whole-heart free-running fat-fraction mapping technique for cardiac MRI in a 6 min scan time, with a resolution of 2mm3 isotropic.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑