arXiv 2307.02708physics.med-phhep-ex
收藏

基于介质层状MCP表面电子产生的低剂量TOF-PET

Low-Dose TOF-PET Based on Surface Electron Production in Dielectric Laminar MCPs

Kepler Domurat-Sousa, Cameron Poe, Henry J. Frisch, Bernhard W. Adams, Camden Ertley, Neal Sullivan

AI总结:

本文提出基于介质层状MCP表面电子产生的低剂量TOF-PET技术,通过模拟验证其可行性,可大幅降低辐射剂量,适用于早期筛查和便携式设备。

摘要:

我们展示了基于511 keV伽马射线通过光电效应和康普顿效应直接表面产生高能电子[1]的全身低剂量飞行时间正电子发射断层扫描(TOF-PET)的模拟,消除了PET扫描仪中的闪烁体和光电探测器子系统。在参考文献[1]中,我们描述了由含有铅或钨等重核的薄介质层构成的微通道板(MCP)(LMCP$^{\ m{TM}}$)。层状表面被微图案化以形成通道,然后可以功能化以支持常规MCP方式的二次电子发射。\n我们使用对TOPAS Geant4工具包的修改来模拟直接转换。一个由150微米厚铅玻璃层组成的20×20×2.54 cm$^3$的LMCP,预计对穿透孔内壁的初级电子具有≥30%的转换效率。随后的二次电子簇射主要限制在一个孔内,可以提供高空间和时间分辨率。\n在全身PET扫描仪中,该技术消除了闪烁体和光电探测器子系统。随之而来的没有光电阴极,允许在大气压下组装大型阵列,并且真空要求不那么严格,包括使用泵送和循环系统。\n我们展示了Derenzo和XCAT脑体模的TOPAS模拟,剂量比文献基准降低了100倍和1000倍。PET在显著较低辐射剂量下的新应用包括常规筛查以早期检测病理,用于以前未服务患者群体(如儿童)的诊断,以及在农村和服务不足人群中扩大安装设施基础,在那里更简单的伽马探测器和更低的辐射剂量可能使小型低成本便携式PET扫描仪成为可能。

英文摘要:

We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects, eliminating the scintillator and photodetector sub-systems in PET scanners. In Ref. [1] we described Microchannel Plates (MCP) constructed from thin dielectric laminae containing heavy nuclei such as lead or tungsten (LMCP$^{\rm{TM}}$). The laminae surfaces are micro-patterned to form channels, which can then be functionalized to support secondary electron emission in the manner of conventional MCPs. We have simulated direct conversion using modifications to the TOPAS Geant4-based tool kit. A 20 $\times$ 20 $\times$ 2.54 cm$^3$ LMCP, composed of 150-micron thick lead-glass laminae, is predicted to have a $\ge 30$% conversion efficiency to a primary electron that penetrates an interior wall of a pore. The subsequent secondary electron shower is largely confined to one pore and can provide high space and time resolutions. In whole-body PET scanners the technique eliminates the scintillator and photodetector subsystems. The consequent absence of a photocathode allows assembly of large arrays at atmospheric pressure and less stringent vacuum requirements, including use of pumped and cycled systems. TOPAS simulations of the Derenzo and XCAT-brain phantoms are presented with dose reductions of factors of 100 and 1000 from a literature benchmark. New applications of PET at a significantly lower radiation dose include routine screening for early detection of pathologies, the use in diagnostics in previously unserved patient populations such as children, and a larger installed facility base in rural and under-served populations, where simpler gamma detectors and lower radiation doses may enable small low-cost portable PET scanners.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑