Joint MR sequence optimization beats pure neural network approaches for spin-echo MRI super-resolution
Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU)(弗里德里希-亚历山大-埃尔兰根-纽伦堡大学);Technical University of Munich(慕尼黑工业大学);Munich Center for Machine Learning(慕尼黑机器学习中心)
Hoai Nam Dang, Vladimir Golkov, Thomas Wimmer, Daniel Cremers, Andreas Maier, Moritz Zaiss
备注:
13 pages, 4 figures, 3 tables, submitted to MICCAI 2023 for review
Current MRI super-resolution (SR) methods only use existing contrasts acquired from typical clinical sequences as input for the neural network (NN). In turbo spin echo sequences (TSE) the sequence parameters can have a strong influence on the actual resolution of the acquired image and have consequently a considera-ble impact on the performance of the NN. We propose a known-operator learning approach to perform an end-to-end optimization of MR sequence and neural net-work parameters for SR-TSE. This MR-physics-informed training procedure jointly optimizes the radiofrequency pulse train of a proton density- (PD-) and T2-weighted TSE and a subsequently applied convolutional neural network to predict the corresponding PDw and T2w super-resolution TSE images. The found radiofrequency pulse train designs generate an optimal signal for the NN to perform the SR task. Our method generalizes from the simulation-based optimi-zation to in vivo measurements and the acquired physics-informed SR images show higher correlation with a time-consuming segmented high-resolution TSE sequence compared to a pure network training approach.
Measurements Automatically Extracted from Zero Echo Time MRI Using Deep Learning Image Segmentation and Geometric Modeling Agree with Expert Manual Readings
Artificial Intelligence-assisted Pixel-level Lung (APL) Scoring for Fast and Accurate Quantification in Ultra-short Echo-time MRI
Australian E-health Research Centre, CSIRO(澳大利亚电子健康研究中心,联邦科学与工业研究组织);The University of Queensland(昆士兰大学);Queensland Children's Hospital(昆士兰儿童医院);Siemens Healthcare Pty Ltd(西门子医疗有限公司);Siemens Healthineers AG(西门子医疗股份公司)
University Medical Center Freiburg, Faculty of Medicine, University of Freiburg(弗赖堡大学医学院弗赖堡大学医学中心);University of North Carolina, Chapel Hill(北卡罗来纳大学教堂山分校)
Motion-Robust T2* Quantification from Gradient Echo MRI with Physics-Informed Deep Learning
Institute of Machine Learning in Biomedical Imaging , Helmholtz Munich , Germany;School of Computation, Information \& Technology , Technical University of Munich , Germany;School of Medicine \& Health, Institute for Diagnostic;Interventional Neuroradiology , Technical University of Munich , Germany;School of Medicine \& Health, TUM-Neuroimaging Center , Technical University of Munich , Germany;Philips GmbH Market DACH , Germany;School of Medicine \& Health, Clinic of Neurology , Technical University of Munich , Germany;School of Biomedical Engineering \& Imaging Sciences , King’s College London , UK
A very simple, robust and fast method for estimating and displaying average time constants of T2 decays from multiecho MRI images using color intensity projections
An analytical Model which Determines the Apparent T1 for Modified Look-Locker Inversion Recovery (MOLLI) -- Analysis of the Longitudinal Relaxation under the Influence of Discontinuous Balanced and Spoiled Gradient Echo Readouts
Fast and Robust T1 Mapping Based on a 3D Dual-Echo UTE Sequence (PETALUTE) for SPION Biodistribution Assessment
Purdue University(普渡大学);University of Cambridge(剑桥大学);German Cancer Research Center (DKFZ)(德国癌症研究中心);University of California San Diego(加州大学圣地亚哥分校);University of North Carolina at Chapel Hill(北卡罗来纳大学教堂山分校);University of Freiburg(弗赖堡大学);University of Oxford(牛津大学);Sunnybrook Research Institute(桑尼布鲁克研究所);University of Toronto(多伦多大学)
A data-Oriented based Self-Calibration And Robust chemical-shift encoding by using clusterization (OSCAR) - Theory, Optimization and Clinical Validation in Neuromuscular disorders
Time-efficient combined morphologic and quantitative joint MRI based on clinical image contrasts -- An exploratory in-situ study of standardized cartilage defects
Denoising of Three-Dimensional Fast Spin Echo Magnetic Resonance Images of Knee Joints using Spatial-Variant Noise-Relevant Residual Learning of Convolution Neural Network
High-spatial resolution, high-quality white matter tractography using DTI with dynamic slice-by-slice B0 shimming in a head-only high-gradient performance 3T MRI scanner
Region of Interest focused MRI to Synthetic CT Translation using Regression and Classification Multi-task Network
GE Healthcare(通用电气医疗集团);Umeå University(于默奥大学);Erasmus MC Cancer Institute(伊拉斯谟医学中心癌症研究所);Newcastle University(纽卡斯尔大学);Newcastle upon Tyne Hospitals NHS Foundation Trust(泰恩河畔纽卡斯尔NHS基金会信托);Technical University of Munich(慕尼黑工业大学);Sree Chitra Tirunal Institute of Medical Sciences and Technology(斯里奇特拉蒂鲁纳尔医学科学与技术研究所);University of Zurich(苏黎世大学)
MRzero -- Fully automated discovery of MRI sequences using supervised learning
目的:提出了一种有监督的学习框架,以基于感兴趣的目标对比度自动生成MR序列和相应的重建。结合灵活的任务驱动成本函数,这允许有效探索新的MR序列策略。研究方法:根据RF事件、x和y方向的梯度矩事件以及延迟时间,端到端地模拟扫描和重建过程,其作用于根据质子密度T1和T2以及$Δ$ B 0给出的输入模型自旋系统。作为概念证明,我们使用传统的MR图像和T1图作为目标,并使用由数据保真度,SAR惩罚和扫描时间定义的损失从头开始优化。结果如下:在第一次尝试中,\textit{MRzero}从零开始学习梯度和RF事件,并且能够生成由常规梯度回波序列产生的目标图像。在重建模块中使用神经网络可以成功学习任意目标。实验可以转化为在真实系统(3 T Siemens,PRISMA)上的图像采集,并且可以在体模和人脑\textit{in vivo}的测量中进行验证。结论:基于可微Bloch方程模拟和监督学习方法的自动MR序列生成是可能的。