In radial fast spin-echo MRI, a set of overlapping spokes with an inconsistent T2 weighting is acquired, which results in an averaged image contrast when employing conventional image reconstruction techniques. This work demonstrates that the problem may be overcome with the use of a dedicated reconstruction method that further allows for T2 quantification by extracting the embedded relaxation information. Thus, the proposed reconstruction method directly yields a spin-density and relaxivity map from only a single radial data set. The method is based on an inverse formulation of the problem and involves a modeling of the received MRI signal. Because the solution is found by numerical optimization, the approach exploits all data acquired. Further, it handles multi-coil data and optionally allows for the incorporation of additional prior knowledge. Simulations and experimental results for a phantom and human brain in vivo demonstrate that the method yields spin-density and relaxivity maps that are neither affected by the typical artifacts from TE mixing, nor by streaking artifacts from the incomplete k-space coverage at individual echo times.
Artificial Intelligence-assisted Pixel-level Lung (APL) Scoring for Fast and Accurate Quantification in Ultra-short Echo-time MRI
Australian E-health Research Centre, CSIRO(澳大利亚电子健康研究中心,联邦科学与工业研究组织);The University of Queensland(昆士兰大学);Queensland Children's Hospital(昆士兰儿童医院);Siemens Healthcare Pty Ltd(西门子医疗有限公司);Siemens Healthineers AG(西门子医疗股份公司)
Joint MR sequence optimization beats pure neural network approaches for spin-echo MRI super-resolution
Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU)(弗里德里希-亚历山大-埃尔兰根-纽伦堡大学);Technical University of Munich(慕尼黑工业大学);Munich Center for Machine Learning(慕尼黑机器学习中心)
University Medical Center Freiburg, Faculty of Medicine, University of Freiburg(弗赖堡大学医学院弗赖堡大学医学中心);University of North Carolina, Chapel Hill(北卡罗来纳大学教堂山分校)
Motion-Robust T2* Quantification from Gradient Echo MRI with Physics-Informed Deep Learning
Institute of Machine Learning in Biomedical Imaging , Helmholtz Munich , Germany;School of Computation, Information \& Technology , Technical University of Munich , Germany;School of Medicine \& Health, Institute for Diagnostic;Interventional Neuroradiology , Technical University of Munich , Germany;School of Medicine \& Health, TUM-Neuroimaging Center , Technical University of Munich , Germany;Philips GmbH Market DACH , Germany;School of Medicine \& Health, Clinic of Neurology , Technical University of Munich , Germany;School of Biomedical Engineering \& Imaging Sciences , King’s College London , UK
Measurements Automatically Extracted from Zero Echo Time MRI Using Deep Learning Image Segmentation and Geometric Modeling Agree with Expert Manual Readings
A very simple, robust and fast method for estimating and displaying average time constants of T2 decays from multiecho MRI images using color intensity projections
Fast and Robust T1 Mapping Based on a 3D Dual-Echo UTE Sequence (PETALUTE) for SPION Biodistribution Assessment
Purdue University(普渡大学);University of Cambridge(剑桥大学);German Cancer Research Center (DKFZ)(德国癌症研究中心);University of California San Diego(加州大学圣地亚哥分校);University of North Carolina at Chapel Hill(北卡罗来纳大学教堂山分校);University of Freiburg(弗赖堡大学);University of Oxford(牛津大学);Sunnybrook Research Institute(桑尼布鲁克研究所);University of Toronto(多伦多大学)
Motion and temporal B0 shift corrections for quantitative susceptibility mapping (QSM) and R2* mapping using dual-echo spiral navigators and conjugate-phase reconstruction
Denoising of Three-Dimensional Fast Spin Echo Magnetic Resonance Images of Knee Joints using Spatial-Variant Noise-Relevant Residual Learning of Convolution Neural Network
A data-Oriented based Self-Calibration And Robust chemical-shift encoding by using clusterization (OSCAR) - Theory, Optimization and Clinical Validation in Neuromuscular disorders
College of Health Science and Environmental Engineering, Shenzhen Technology University(深圳科技大学健康科学与环境工程学院);University Medical Center Göttingen(哥廷根大学医学中心);Guangdong-Hongkong-Macau CNS Regeneration Institute, Key Laboratory of CNS Regeneration (Jinan University)-Ministry of Education, Jinan University(广东-港澳-澳门神经科学再生研究所,神经科学再生重点实验室(暨南大学)-教育部,暨南大学);Department of Radiology, The First Hospital of Tsinghua University(清华大学第一医院放射科);Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University(清华大学生物医学成像研究中心,生物医学工程系,医学院);Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science, Zhejiang University(教育部生物医学工程重点实验室,生物医学工程与仪器科学学院,浙江大学);Department of Endocrinology and Metabolism, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine(浙江大学医学院邵逸夫医院内分泌科);Lab of Molecular Imaging and Medical Intelligence, Department of Radiology, Longgang Central Hospital of Shenzhen (Shenzhen Clinical Medical College, Guangzhou University of Chinese Medicine(分子成像与医学智能实验室,放射科,深圳龙岗中心医院(深圳临床医学院,广州中医药大学;龙岗临床学院,汕头大学医学院));Longgang Clinical Institute of Shantou University Medical College)
Axial and radial axonal diffusivities from single encoding strongly diffusion-weighted MRI
我们能够从单编码,强扩散加权,脉冲梯度自旋回波数据的每轴突轴向扩散率的估计。此外,我们提高了每轴突径向扩散率的估计相比,估计基于球面平均。在磁共振成像(MRI)中使用强扩散加权允许将白质中的信号近似为来自轴突的贡献的总和。同时,球面平均通过消除明确考虑轴突的未知方向分布的需要而导致建模的主要简化。然而,在强扩散加权下获得的球形平均信号对轴向扩散率不敏感,因此无法估计轴向扩散率。在对现有理论进行修正后,我们提出了一种新的基于带谐函数模型的强扩散加权条件下轴突扩散率的通用估计方法。我们还展示了如何这可能导致估计是免费的部分体积偏差,例如,灰质。我们在MGH Adult Diffusion Human Connectome项目数据集的公开数据上测试了该方法。我们报告的轴突扩散系数的参考值的基础上34个科目,并推导出轴突半径的估计。我们还从所需的数据预处理,与建模假设相关的偏差的存在,当前的限制和未来的可能性的角度来解决估计问题。