基于PETALUTE的快速且稳健的T1映射:用于SPION生物分布评估
Fast and Robust T1 Mapping Based on a 3D Dual-Echo UTE Sequence (PETALUTE) for SPION Biodistribution Assessment
AI总结:
本研究提出基于PETALUTE的快速T1映射技术,实现对SPION生物分布的高精度定量成像,具有更广的浓度范围和更高的空间覆盖能力。
摘要:
超-paramagnetic铁氧化物纳米颗粒(如Feuromoxytol)是具有MRI检测潜力的新型治疗-诊断剂。弛豫时间映射提供了SPION分布的可重复、定量生物标志物,但传统方法因磁化率伪影、长回波时间及扫描时间长而限制了准确量化。本研究开发了一种快速、B1校正的T1映射协议,使用PETALUTE,一种具有玫瑰状k空间轨迹和可变翻转角采集的3D双回波超短回波MRI序列,用于定量Feuromoxytol成像。含0-5000ppm Feuromoxytol的琼脂基质在7T下使用PETALUTE和供应商提供的RARE-VTR进行扫描。PETALUTE的T1图谱由两个翻转角(4度和20度)得出,平均R1值与Feuromoxytol浓度相关联。对于体内可行性,4T1乳腺和 flank 肿瘤荷瘤小鼠在注射后24小时进行扫描(Feuromoxytol:n=2,40mg/kg;对照:n=1)。在肌肉和肿瘤区域分析T1和R1值以比较两种方法的结果。PETALUTE在所有假体浓度(除了5000ppm)上产生正对比,而RARE-VTR则没有。PETALUTE显示出R1与Feuromoxytol浓度之间显著的线性相关性(R=0.975,p<0.01),与RARE-VTR(R=0.672,p=0.144)形成对比。体内,PETALUTE在4分19秒内实现了高分辨率的全腹部成像。Feuromoxytol注射小鼠在flank肿瘤中显示T1缩短,与铁摄入一致,而PETALUTE在乳腺肿瘤中显示出升高的T1值,同时保持T2*-加权信号。基于PETALUTE的T1映射提供了快速、定量、正对比的Feuromoxytol成像,具有比传统RARE-VTR更广泛的空间覆盖范围和更宽的可用浓度范围。
英文摘要:
Superparamagnetic iron oxide nanoparticles (SPIONs) such as ferumoxytol are promising theranostic agents detectable with MRI. Relaxation time mapping offers reproducible, quantitative biomarkers of SPION distribution, but conventional methods suffer from susceptibility artifacts, long echo times, and extended scan durations, limiting accurate quantification. This study developed a fast, B1-corrected T1-mapping protocol using PETALUTE, a 3D dual-echo ultrashort-echo MRI sequence with a rosette k-space trajectory and variable flip-angle acquisition for quantitative ferumoxytol imaging. Agarose phantoms containing 0-5000 ppm ferumoxytol were scanned at 7T with PETALUTE and vendor-supplied RARE-VTR. PETALUTE T1 maps were derived from two flip angles (4 deg and 20 deg), and mean R1 values were correlated with ferumoxytol concentration. For in vivo feasibility, mice bearing 4T1 mammary and flank tumors were scanned 24 h post-injection (ferumoxytol: n=2, 40 mg/kg; control: n=1). Regions of interest in muscle and tumors were analyzed to compare T1 and R1 values obtained with both methods. PETALUTE produced positive contrast for all phantom concentrations except 5000 ppm, whereas RARE-VTR did not. PETALUTE demonstrated a significant linear correlation between R1 and ferumoxytol concentration (R=0.975, p<0.01), in contrast to RARE-VTR (R=0.672, p=0.144). In vivo, PETALUTE enabled high-resolution, whole-abdominal imaging in 4 min 19 s. Ferumoxytol-injected mice showed T1 shortening in flank tumors, consistent with iron uptake, and PETALUTE revealed elevated T1 value with preserved T2*-weighted signal in one mammary tumor. PETALUTE-based T1 mapping provides fast, quantitative, positive-contrast ferumoxytol imaging with greater spatial coverage and a wider usable concentration range than conventional RARE-VTR.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。