用于身体成像的自由呼吸运动补偿4D(3D+呼吸)T2-weighted turbo自旋回波MRI
Free-breathing motion compensated 4D (3D+respiration) T2-weighted turbo spin-echo MRI for body imaging
摘要:
目的:开发和评价自由呼吸呼吸运动补偿4D(3D+呼吸)$T_2$加权快速自旋回波序列,并将其应用于放射学和MR引导放射治疗。研究方法:使用具有螺旋轮廓排序(rCASPR)的重绕笛卡尔采集来连续采集k空间数据,以提供与常规线性相位编码排序的匹配对比度,并将数据分类为多个呼吸相位。利用压缩感知重建低分辨率的运动相关4D图像,并用于估计非刚性变形矢量场,随后将其用于运动补偿图像重建。在点扩散函数(PSF)和图像对比度方面,将rCASPR采样与线性和CASPR采样进行了比较,并进行了计算机模拟、体模和体内实验。使用网格搜索确定低分辨率4D-MRI的重建参数(空间分辨率和时间正则化)。在8名健康志愿者中评估了拟议的运动补偿rCASPR,并与线性采样的自由呼吸扫描进行了比较。图像质量的比较基于视觉检测和定量的梯度熵的手段。结果如下:rCASPR提供了更好的PSF(ky相似,kz更窄),与线性采样相比,图像对比度无显著差异。最佳4D-MRI重建参数为空间分辨率= $4.5 mm^3$和$λ_t=10^{-4}$。线性、rCASPR、软门控rCASPR和运动补偿rCASPR的组平均梯度熵分别为22.31、22.20、22.14和22.02。结论:所提出的运动补偿rCASPR能够以最小的图像对比度和扫描时间变化实现高质量的自由呼吸T2-TSE。因此,所提出的方法能够将临床使用的3D TSE序列直接转移到自由呼吸。
英文摘要:
Purpose: To develop and evaluate a free-breathing respiratory motion compensated 4D (3D+respiration) $T_2$-weighted turbo spin echo sequence with application to radiology and MR-guided radiotherapy. Methods: k-space data are continuously acquired using a rewound Cartesian acquisition with spiral profile ordering (rCASPR) to provide matching contrast to the conventional linear phase encode ordering and to sort data into multiple respiratory phases. Low-resolution respiratory-correlated 4D images were reconstructed with compressed sensing and used to estimate non-rigid deformation vector fields, which were subsequently used for a motion compensated image reconstruction. rCASPR sampling was compared to linear and CASPR sampling in terms of point-spread-function (PSF) and image contrast with in silico, phantom and in vivo experiments. Reconstruction parameters for low-resolution 4D-MRI (spatial resolution and temporal regularization) were determined using a grid search. The proposed motion compensated rCASPR was evaluated in eight healthy volunteers and compared to free-breathing scans with linear sampling. Image quality was compared based on visual inspection and quantitatively by means of the gradient entropy. Results: rCASPR provided a superior PSF (similar in ky and narrower in kz) and showed no considerable differences in images contrast compared to linear sampling. The optimal 4D-MRI reconstruction parameters were spatial resolution=$4.5 mm^3$ and $λ_t=10^{-4}$. The groupwise average gradient entropy was 22.31 for linear, 22.20 for rCASPR, 22.14 for soft-gated rCASPR and 22.02 for motion compensated rCASPR. Conclusion: The proposed motion compensated rCASPR enables high quality free-breathing T2-TSE with minimal changes in image contrast and scan time. The proposed method therefore enables direct transfer of clinically used 3D TSE sequences to free-breathing.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。