arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2203.16288eess.IVcs.AIcs.CVphysics.med-ph
收藏

使用回归和分类多任务网络将关注区域的MRI转换为合成CT

Region of Interest focused MRI to Synthetic CT Translation using Regression and Classification Multi-task Network

GE Healthcare(通用电气医疗集团);Umeå University(于默奥大学);Erasmus MC Cancer Institute(伊拉斯谟医学中心癌症研究所);Newcastle University(纽卡斯尔大学);Newcastle upon Tyne Hospitals NHS Foundation Trust(泰恩河畔纽卡斯尔NHS基金会信托);Technical University of Munich(慕尼黑工业大学);Sree Chitra Tirunal Institute of Medical Sciences and Technology(斯里奇特拉蒂鲁纳尔医学科学与技术研究所);University of Zurich(苏黎世大学)
Sandeep Kaushik, Mikael Bylund, Cristina Cozzini, Dattesh Shanbhag, Steven F Petit, Jonathan J Wyatt, Marion I Menzel, Carolin Pirkl, Bhairav Mehta, Vikas Chauh… 展开作者

Sandeep Kaushik, Mikael Bylund, Cristina Cozzini, Dattesh Shanbhag, Steven F Petit, Jonathan J Wyatt, Marion I Menzel, Carolin Pirkl, Bhairav Mehta, Vikas Chauhan, Kesavadas Chandrasekharan, Joakim Jonsson, Tufve Nyholm, Florian Wiesinger, Bjoern Menze

摘要:

在这项工作中,我们提出了一种从零回波时间(ZTE)MRI生成合成CT(sCT)的方法,旨在提高图像的结构和定量精度,特别关注准确的骨密度值预测。我们提出了一个损失函数,有利于图像中的空间稀疏区域。我们利用多任务网络产生相关输出的能力作为框架,通过分类实现感兴趣区域(RoI)的本地化,强调RoI内值的回归,并通过全局回归保持整体准确性。该网络通过组合每个任务的专用损失的复合损失函数进行优化。我们演示了如何与ROI集中损失的多任务网络提供了一个优势,比其他配置的网络,以实现更高的性能精度。这与sCT相关,其中无法准确估计骨的高亨氏单位值可能导致临床应用中的准确性受损。我们比较了放射疗法治疗计划设置中来自建议的sCT和真实CT的剂量计算图。

英文摘要:

In this work, we present a method for synthetic CT (sCT) generation from zero-echo-time (ZTE) MRI aimed at structural and quantitative accuracies of the image, with a particular focus on the accurate bone density value prediction. We propose a loss function that favors a spatially sparse region in the image. We harness the ability of a multi-task network to produce correlated outputs as a framework to enable localisation of region of interest (RoI) via classification, emphasize regression of values within RoI and still retain the overall accuracy via global regression. The network is optimized by a composite loss function that combines a dedicated loss from each task. We demonstrate how the multi-task network with RoI focused loss offers an advantage over other configurations of the network to achieve higher accuracy of performance. This is relevant to sCT where failure to accurately estimate high Hounsfield Unit values of bone could lead to impaired accuracy in clinical applications. We compare the dose calculation maps from the proposed sCT and the real CT in a radiation therapy treatment planning setup.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑