This paper presents a trajectory tracking control strategy that modulates the active power injected by geographically distributed inverter-based resources to support transient stability. Each resource is independently controlled, and its response drives the local bus voltage angle toward a trajectory that tracks the angle of the center of inertia. The center-of-inertia angle is estimated in real time from wide-area measurements. The main objectives are to stabilize transient disturbances and increase the amount of power that can be safely transferred over key transmission paths without loss of synchronism. Here we envision the actuators as utility-scale energy storage systems; however, equivalent examples could be developed for partially-curtailed photovoltaic generation and/or Type 4 wind turbine generators. The strategy stems from a time-varying linearization of the equations of motion for a synchronous machine. The control action produces synchronizing torque in a special reference frame that accounts for the motion of the center of inertia. This drives the system states toward the desired trajectory and promotes rotor angle stability. For testing we employ a reduced-order dynamic model of the North American Western Interconnection. The results show that this approach improves system reliability and can increase capacity utilization on stability-limited transmission corridors.
A disturbance-aware predictive control policy is proposed for DC-AC power inverters with the receding horizon optimization approach. First, a discrete event-driven hybrid automaton model has been constructed for the nonlinear inverter system dynamics. A control problem of infinite discrete state-space transition sequence optimization is formulated. A receding horizon optimization approach is applied to solve the discrete optimization problem piece-wisely on-line. Accordingly, disturbance-aware adaptive control is proposed, the external disturbance is sampled and estimated by an on-line Recursi…
Inverter-connected resources can improve transient stability in low-inertia grids by injecting active power to minimize system frequency deviations following disturbances. In practice, most generation and load disturbances are step changes and the engineering figure-of-merit is often the peak overshoot in frequency resulting from these step disturbances. In addition, the inverter-connected resources tend to saturate much more easily than conventional synchronous machines. However, despite these challenges, standard controller designs must deal with averaged quantities through $H_2$ or $H_\inft…
This article proposes the design of H-infinity-based robust current controller for single-phase grid-feeding voltage source inverter with an LCL filter. The main objective of the proposed controller is to have good reference tracking, disturbance rejection and sufficient LCL resonance damping under a large range of variations of grid impedance. Based on the aforementioned performance requirements, frequency dependent weighting functions are designed. Subsequently, the sub-optimal control problem is formulated and solved to determine the stabilizing controller. Computational footprint of the co…
Autonomous droop control PV inverters have improved voltage regulation compared to the inverters without grid support functions, but more flexible control techniques will be required as the number of solar photovoltaic (PV) installations increases. This paper studies three inverter future deployment scenarios with droop control inverters, non-exporting inverters, and coordinated inverter control (CIC). The network operation and the interaction between various inverter control methods are studied by simulating inverter operation on two low-voltage networks. Considering 30% PV penetration as the…
The electrical grid is evolving from a network consisting of mostly synchronous machines to a mixture of synchronous machines and inverter-based resources such as wind, solar, and energy storage. This transformation has led to a decrease in mechanical inertia, which necessitate a need for the new resources to provide frequency responses through their inverter interfaces. In this paper we proposed a new strategy based on model predictive control to determine the optimal active-power set-point for inverters in the event of a disturbance in the system. Our framework explicitly takes the hard cons…
Grid-forming inverter-based autonomous microgrids present new operational challenges as the stabilizing rotational inertia of synchronous machines is absent. The design of efficient control policies for grid-forming inverters is, however, a non-trivial problem where multiple performance objectives need to be satisfied, including voltage/frequency regulation, current limiting capabilities, as well as active power sharing and a scalable operation. We propose in this paper a novel control architecture for frequency and voltage control which allows current limitation via an inner loop, active powe…
Due to the rise of distributed energy resources, the control of networks of grid-forming inverters is now a pressing issue for power system operation. Droop control is a popular control strategy in the literature for frequency control of these inverters. In this paper, we analyze transient stability in droop-controlled inverter networks that are subject to multiple operating constraints. Using a physically-meaningful Lyapunov-like function, we provide two sets of criteria (one mathematical and one computational) to certify that a post-fault trajectory achieves frequency synchronization while r…
Fast-acting smart inverters that utilize preset operating conditions to determine real and reactive power injection/consumption can create voltage instabilities (over-voltage, voltage oscillations and more) in an electrical distribution network if set-points are not properly configured. In this work, linear distribution power flow equations and droop-based Volt-Var and Volt-Watt control curves are used to analytically derive a stability criterion using \lyapnouv analysis that includes the network operating condition. The methodology is generally applicable for control curves that can be repres…
A power system electromechanical wave propagates from the disturbance location to the rest of system, influencing various types of protections. In addition, since more power-electronics-interfaced generation and energy storage devices are being integrated into power systems, electromechanical wave propagation speeds in the future power systems are likely to change accordingly. In this paper, GPS-synchronized measurement data from a wide-area synchrophasor measurement system FNET/GridEye are used to analyze the characteristics of electromechanical wave propagation in the U.S. Eastern Interconne…
In a purely inverter-based microgrid, both grid-forming (GFM) and grid-following (GFL) inverters will have a crucial role to play in frequency/voltage regulation and maintaining power sharing through their grid support capabilities. Consequently, the coordination between these two technologies becomes increasingly important for optimal system performance. However, the existing work does not consider GFL's potential to participate in a secondary control in coordination with GFM, thus not able to utilize the full capability of inverter resources. In this paper, we show that it is possible to ful…
Advanced microgrids consisting of distributed energy resources interfaced with multi-inverter systems are becoming more common. Consequently, the effectiveness of voltage and frequency regulation in microgrids using conventional droop-based methodologies is challenged by uncertainty in the sizeand schedule of loads. This article proposes an isochronous architecture of parallel inverters with only voltage-active power droop (VP-D) control for improving active power sharing as well as plug-and-play of multi-inverter based distributed energyresources (DERs). In spite of not employing explicit con…
With increased attention on grid-forming inverters as a power system stabilizing device during periods of high shares of inverter-based resource operations, there is a present need for a transparent and rigorous investigation of the inverted and direct power to frequency control capabilities, and associated impacts, of these devices on hybrid systems. Here, analysis of the frequency dynamics of the droop controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for no…
This paper presents a novel control structure and control synthesis method for regulating the output voltage/frequency and power injection of DC-AC inverters. The traditional droop method offers attractive solution to achieve compromise between clashing power and voltage/frequency regulation objectives. However, it relies on use of nonlinear power variables through slow outer control loop. In this paper we formulate the traditional droop method as a feedback control problem based on static power-flow equations and show how neglecting the dynamics of inverter and transmission line restricts the…
A Control Architecture for Fast Frequency Regulation with Increasing Penetration of Inverter Based Resources (Extended Version)
Massachusetts Institute of Technology(麻省理工学院);King Fahd University of Petroleum & Minerals(法赫德国王石油与矿产大学);King Abdulaziz City for Science and Technology(阿卜杜勒阿齐兹国王科学与技术城)
As more inverter-connected renewable resources are integrated into the grid, frequency stability may degrade because of the reduction in mechanical inertia and damping. A common approach to mitigate this degradation in performance is to use the power electronic interfaces of the renewable resources for primary frequency control. Since inverter-connected resources can realize almost arbitrary responses to frequency changes, they are not limited to reproducing the linear droop behaviors. To fully leverage their capabilities, reinforcement learning (RL) has emerged as a popular method to design n…
Modern safety-critical energy infrastructures are increasingly operated in a hierarchical and modular control framework which allows for limited data exchange between the modules. In this context, it is important for each module to synthesize and communicate constraints on the values of exchanged information in order to assure system-wide safety. To ensure transient safety in inverter-based microgrids, we develop a set invariance-based distributed safety verification algorithm for each inverter module. Applying Nagumo's invariance condition, we construct a robust polynomial optimization proble…
We propose a novel hierarchical frequency and voltage control design for multi-area power system integrated with inverter-based resources (IBRs). The design is based on the idea of prioritizing the use of IBRs over conventional generator-based control in compensating for sudden and unpredicted changes in loads and generations, and thereby mitigate any undesired dynamics in the frequency or the voltage by exploiting their fast actuation time constants. A new sequential optimization problem, referred to as Area Prioritized Power Flow (APPF), is formulated to model this prioritization. It is show…
This paper evaluates the frequency performance of an AC system when primary frequency response is provided by inverter-based resources located at remote-areas. Due to potentially larger wave propagation constants over longer lines, fast active power response from inverter based resources may have a negative impact on the system frequency response. Within this context, this paper presents a control performance analysis is presented in order to identify limitations for improving the frequency stability when inverter-based resources in remote locations use local frequency measurements. Our result…
An increase in the integration of Inverter Based Resources (IBRs) to the electric grid, will lead to a corresponding decrease in the amount of connected synchronous generators, resulting in a decline in the available rotational inertia system-wide. This can lead to pronounced frequency deviations when there are disturbances and faults in the grid. This decline in available rotational inertia can be compensated for by fast acting IBRs participating in frequency response services, by rapidly injecting into or removing power from the grid. Currently, there are still relative small number of sizab…
This paper proposes a new concept called virtual inertia scheduling (VIS) to efficiently handle the high penetration of inverter-based resources (IBRs). VIS is an inertia management framework that targets security-constrained and economy-oriented inertia scheduling and generation dispatch of power systems with a large scale of renewable generations. Specifically, it schedules the proper power setting points and reserved capacities of both synchronous generators and IBRs, as well as the control modes and control parameters of IBRs to provide secure and cost-effective inertia support. First, a u…